1.3.6.1.4.1.211Nodefujitsu
1.3.6.1.4.1.211.1Nodeproducts
1.3.6.1.4.1.211.1.31NodeiaServer
1.3.6.1.4.1.211.1.31.1Nodeprimequest
1.3.6.1.4.1.211.1.31.1.2Nodepartition
1.3.6.1.4.1.211.1.31.1.2.200NodeparititonVariables
1.3.6.1.4.1.211.1.31.1.2.200.1NodetrapVarComInfo
1.3.6.1.4.1.211.1.31.1.2.200.1.1ScalartrapPartitionNamenot-accessiblemandatoryPartition name which trap is generated.
1.3.6.1.4.1.211.1.31.1.2.200.1.2ScalartrapPartitionIdnot-accessiblemandatoryParitition identifier which trap is generated.
1.3.6.1.4.1.211.1.31.1.2.200.1.3ScalartrapEventLevelnot-accessiblemandatoryEvent level
1.3.6.1.4.1.211.1.31.1.2.200.1.4ScalartrapEventIdnot-accessiblemandatoryEvent Identifier
1.3.6.1.4.1.211.1.31.1.2.200.1.5ScalartrapUnitNamenot-accessiblemandatoryUnit name which trap is generated.
1.3.6.1.4.1.211.1.31.1.2.200.1.6ScalartrapMmbVipnot-accessiblemandatoryManagement board vertual IP address.
1.3.6.1.4.1.211.1.31.1.2.200.2NodetrapVarDivInfo
1.3.6.1.4.1.211.1.31.1.2.200.2.1ScalartrapPartNonot-accessiblemandatoryParts number of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.2ScalartrapSteppingnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.3ScalartrapSerialNonot-accessiblemandatorySerial number of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.4ScalartrapModelNonot-accessiblemandatoryModel number of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.5ScalartrapSuspectnot-accessiblemandatoryLogical name or pci bus number of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.6ScalartrapVendorIdnot-accessiblemandatoryVendor identifier of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.7ScalartrapDeviceIdnot-accessiblemandatoryDevice identifier of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.8ScalartrapRevisionnot-accessiblemandatoryRevision of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.9ScalartrapCardNamenot-accessiblemandatoryDevice name of trap source.
1.3.6.1.4.1.211.1.31.1.2.200.2.10ScalartrapErrDetailnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.11ScalartrapErrCodenot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.12ScalartrapIrpCodenot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.13ScalartrapHbaNonot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.14ScalartrapErrCausenot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.15ScalartrapPathNonot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.16ScalartrapDiskIdnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.17ScalartrapFmrDiskIdnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.18ScalartrapCurDiskIdnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.19ScalartrapPathIdnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.20ScalartrapPhysIfnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.21ScalartrapVirtualIfnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.22ScalartrapLogicalIpnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.23ScalartrapWatchIpnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.24ScalartrapInterfacenot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.25ScalartrapSourceIpnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.26ScalartrapDestIpnot-accessiblemandatory
1.3.6.1.4.1.211.1.31.1.2.200.2.27ScalartrapModelNamenot-accessiblemandatoryModel name of trap source.
1.3.6.1.4.1.211.1.31.1.2.201NodepartitionEnterprise
1.3.6.1.4.1.211.1.31.1.2.201.1NodepsaComTrap
1.3.6.1.4.1.211.1.31.1.2.201.51NodepsaWinIntelE100Trap
1.3.6.1.4.1.211.1.31.1.2.201.52NodepsaWinIntelE1000Trap
1.3.6.1.4.1.211.1.31.1.2.201.53NodepsaWinBcm5700Trap
1.3.6.1.4.1.211.1.31.1.2.201.54NodepsaWinEmulexTrap
1.3.6.1.4.1.211.1.31.1.2.201.55NodepsaWinLsiLogicTrap
1.3.6.1.4.1.211.1.31.1.2.201.56NodepsaWinDiskTrap
1.3.6.1.4.1.211.1.31.1.2.201.57NodepsaWinGrmpdTrap
1.3.6.1.4.1.211.1.31.1.2.201.58NodepsaWinDiskMirrorTrap
1.3.6.1.4.1.211.1.31.1.2.201.59NodepsaWinXframe2Trap
1.3.6.1.4.1.211.1.31.1.2.201.60NodepsaWinIntelE1000expTrap
1.3.6.1.4.1.211.1.31.1.2.201.61NodepsaWinSvsRaidTrap
1.3.6.1.4.1.211.1.31.1.2.201.61.28500NodesvraidWinEvent0SV RAID: Adapter error (BBU temperature out of range)
1.3.6.1.4.1.211.1.31.1.2.201.61.28501NodesvraidWinEvent1SV RAID: Adapter error (BBU temperature unstable)
1.3.6.1.4.1.211.1.31.1.2.201.61.28502NodesvraidWinEvent2SV RAID: Adapter error (BBU temperature above threshold)
1.3.6.1.4.1.211.1.31.1.2.201.61.28503NodesvraidWinEvent3SV RAID: Adapter error (BBU voltage out of range)
1.3.6.1.4.1.211.1.31.1.2.201.61.28504NodesvraidWinEvent4SV RAID: Adapter error (BBU voltage unstable)
1.3.6.1.4.1.211.1.31.1.2.201.61.28505NodesvraidWinEvent5SV RAID: Adapter error (BBU communication error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28506NodesvraidWinEvent6SV RAID: Adapter error (BBU failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28507NodesvraidWinEvent7SV RAID: Adapter error (BBU fast charging failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28508NodesvraidWinEvent8SV RAID: Adapter error (BBU charge count exceeded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28509NodesvraidWinEvent9SV RAID: Device error (Rebuild on disk failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28510NodesvraidWinEvent10SV RAID: Device error (Rebuild failed on logical drive)
1.3.6.1.4.1.211.1.31.1.2.201.61.28511NodesvraidWinEvent11SV RAID: Device error (Migration failed on logical drive)
1.3.6.1.4.1.211.1.31.1.2.201.61.28512NodesvraidWinEvent12SV RAID: Device error (Migration aborted on logical drive)
1.3.6.1.4.1.211.1.31.1.2.201.61.28513NodesvraidWinEvent13SV RAID: Device error (Logical drive degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28514NodesvraidWinEvent14SV RAID: Device error (Logical drive failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28515NodesvraidWinEvent15SV RAID: Adapter error (BBU voltage problem detected)
1.3.6.1.4.1.211.1.31.1.2.201.61.28516NodesvraidWinEvent16SV RAID: Adapter error (BBU temperature problem detected)
1.3.6.1.4.1.211.1.31.1.2.201.61.28517NodesvraidWinEvent17SV RAID: Adapter error (BBU failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28518NodesvraidWinEvent18SV RAID: Adapter error (Fatal firmware error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28519NodesvraidWinEvent19SV RAID: Adapter error (Multi-bit ECC error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28520NodesvraidWinEvent20SV RAID: Adapter error (Single-bit ECC error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28521NodesvraidWinEvent21SV RAID: Adapter error (Not enough adapter memory)
1.3.6.1.4.1.211.1.31.1.2.201.61.28522NodesvraidWinEvent22SV RAID: Device error (Resume migration of logical drive failed due to Configuration Mismatch)
1.3.6.1.4.1.211.1.31.1.2.201.61.28523NodesvraidWinEvent23SV RAID: Device error (Hot spare S.M.A.R.T. polling failed on disk)
1.3.6.1.4.1.211.1.31.1.2.201.61.28524NodesvraidWinEvent24SV RAID: Device error (Predictive failure)
1.3.6.1.4.1.211.1.31.1.2.201.61.28525NodesvraidWinEvent25SV RAID: Adapter error (BBU needs to be replaced - SOH bad)
1.3.6.1.4.1.211.1.31.1.2.201.61.28526NodesvraidWinEvent26SV RAID: Adapter error (BBU removed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28527NodesvraidWinEvent27SV RAID: Adapter error (Enclosure communication lost)
1.3.6.1.4.1.211.1.31.1.2.201.61.28528NodesvraidWinEvent28SV RAID: Adapter error (Enclosure not responding)
1.3.6.1.4.1.211.1.31.1.2.201.61.28529NodesvraidWinEvent29SV RAID: Adapter error (SAS/SATA mixing not supported in enclosure)
1.3.6.1.4.1.211.1.31.1.2.201.61.28530NodesvraidWinEvent30SV RAID: Device error (Bad block table on disk is 80 percent full)
1.3.6.1.4.1.211.1.31.1.2.201.61.28531NodesvraidWinEvent31SV RAID: Device error (Bad block table on disk is full; unable to log Block)
1.3.6.1.4.1.211.1.31.1.2.201.61.28532NodesvraidWinEvent32SV RAID: Adapter error (BBU/charger problems detected; SOH bad)
1.3.6.1.4.1.211.1.31.1.2.201.61.28533NodesvraidWinEvent33SV RAID: Adapter error (Single-bit ECC error; warning threshold exceeded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28534NodesvraidWinEvent34SV RAID: Adapter error (Single-bit ECC error; critical threshold exceeded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28535NodesvraidWinEvent35SV RAID: Adapter error (Single-bit ECC error; further reporting disabled)
1.3.6.1.4.1.211.1.31.1.2.201.61.28536NodesvraidWinEvent36SV RAID: Adapter error (Previous configuration completely missing at boot)
1.3.6.1.4.1.211.1.31.1.2.201.61.28537NodesvraidWinEvent37SV RAID: Device error (Logical drive partially degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28538NodesvraidWinEvent38SV RAID: Device error (Disks missing)
1.3.6.1.4.1.211.1.31.1.2.201.61.28539NodesvraidWinEvent39SV RAID: Device error (State change on logical drive from operational to degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28540NodesvraidWinEvent40SV RAID: Device error (State change on logical drive from operational to partially degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28541NodesvraidWinEvent41SV RAID: Device error (State change on logical drive from operational to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28542NodesvraidWinEvent42SV RAID: Device error (State change on logical drive from degraded to degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28543NodesvraidWinEvent43SV RAID: Device error (State change on logical drive from degraded to partially degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28544NodesvraidWinEvent44SV RAID: Device error (State change on logical drive from degraded to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28545NodesvraidWinEvent45SV RAID: Device error (State change on logical drive from partially degraded to degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28546NodesvraidWinEvent46SV RAID: Device error (State change on logical drive from partially degraded to partially degraded)
1.3.6.1.4.1.211.1.31.1.2.201.61.28547NodesvraidWinEvent47SV RAID: Device error (State change on logical drive from partially degraded to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28548NodesvraidWinEvent48SV RAID: Device error (State change on logical drive from failed to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28549NodesvraidWinEvent49SV RAID: Device error (State change by user on disk from failed to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28550NodesvraidWinEvent50SV RAID: Device error (State change by user on disk from hotspare to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28551NodesvraidWinEvent51SV RAID: Device error (State change by user on disk from rebuilding to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28552NodesvraidWinEvent52SV RAID: Device error (State change by user on disk from operational to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28553NodesvraidWinEvent53SV RAID: Device error (State change on disk from failed to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28554NodesvraidWinEvent54SV RAID: Device error (State change on disk from hot spare to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28555NodesvraidWinEvent55SV RAID:%s Device error (State change on disk from rebuilding to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28556NodesvraidWinEvent56SV RAID:%s Device error (State change on disk from operational to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28557NodesvraidWinEvent57SV RAID: Device error (Disk missing after reboot)
1.3.6.1.4.1.211.1.31.1.2.201.61.28558NodesvraidWinEvent58SV RAID: Adapter error (Logical drive missing after reboot)
1.3.6.1.4.1.211.1.31.1.2.201.61.28559NodesvraidWinEvent59SV RAID: Device error (State change by user on disk from hot spare to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28560NodesvraidWinEvent60SV RAID: Device error (State change by user on disk from offline to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28561NodesvraidWinEvent61SV RAID: Device error (State change by user on disk from operational to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28562NodesvraidWinEvent62SV RAID: Device error (State change by user on disk from rebuilding to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28563NodesvraidWinEvent63SV RAID: Device error (State change on disk from hot spare to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28564NodesvraidWinEvent64SV RAID: Device error (State change on disk from offline to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28565NodesvraidWinEvent65SV RAID: Device error (State change on disk from operational to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28566NodesvraidWinEvent66SV RAID: Device error (State change on disk from rebuilding to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28567NodesvraidWinEvent67SV RAID: Adapter error (SAS port lost link)
1.3.6.1.4.1.211.1.31.1.2.201.61.28568NodesvraidWinEvent68SV RAID: Adapter error (Adapter missing after reboot)
1.3.6.1.4.1.211.1.31.1.2.201.61.28569NodesvraidWinEvent69SV RAID: Adapter error (Adapter needs replacement; faulty IOP detected)
1.3.6.1.4.1.211.1.31.1.2.201.61.28570NodesvraidWinEvent70SV RAID: Device error (Microcode update timeout on disk)
1.3.6.1.4.1.211.1.31.1.2.201.61.28571NodesvraidWinEvent71SV RAID: Device error (Microcode update failed on disk)
1.3.6.1.4.1.211.1.31.1.2.201.61.28572NodesvraidWinEvent72SV RAID: Device error (Adapter cache pinned for missing or offline logical drive)
1.3.6.1.4.1.211.1.31.1.2.201.61.28573NodesvraidWinEvent73SV RAID: Device error (Adapter cache pinned for missing or offline logical drives)
1.3.6.1.4.1.211.1.31.1.2.201.61.28574NodesvraidWinEvent74SV RAID: Device error (Adapter cache discarded by user for missing logical drives)
1.3.6.1.4.1.211.1.31.1.2.201.61.28575NodesvraidWinEvent75SV RAID: Device error (Adapter cache destaged for logical drive)
1.3.6.1.4.1.211.1.31.1.2.201.61.28576NodesvraidWinEvent76SV RAID: Adapter error (Internal hardware error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28577NodesvraidWinEvent77SV RAID: Adapter error (Internal hardware error during POST)
1.3.6.1.4.1.211.1.31.1.2.201.61.28578NodesvraidWinEvent78SV RAID: Device error (Bad block table of disk threshold exceeded; table is about to overflow)
1.3.6.1.4.1.211.1.31.1.2.201.61.28579NodesvraidWinEvent79SV RAID: Device error (Disk failed due to bad block table overflow)
1.3.6.1.4.1.211.1.31.1.2.201.61.28580NodesvraidWinEvent80SV RAID: Device error (Disk failure detected during POST)
1.3.6.1.4.1.211.1.31.1.2.201.61.28581NodesvraidWinEvent81SV RAID: Adapter error (Failure detected during POST)
1.3.6.1.4.1.211.1.31.1.2.201.61.28582NodesvraidWinEvent82SV RAID: Device error (Multiple failure on disk detected)
1.3.6.1.4.1.211.1.31.1.2.201.61.28583NodesvraidWinEvent83SV RAID: Device error (Disk failed since it never entered ready state)
1.3.6.1.4.1.211.1.31.1.2.201.61.28584NodesvraidWinEvent84SV RAID: Adapter error (Internal software interface error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28585NodesvraidWinEvent85SV RAID: Adapter error (Device open error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28586NodesvraidWinEvent86SV RAID: Adapter error (Ioctl send error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28587NodesvraidWinEvent87SV RAID: Adapter error (Insufficient application memory)
1.3.6.1.4.1.211.1.31.1.2.201.61.28588NodesvraidWinEvent88SV RAID: Adapter error (System API error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28589NodesvraidWinEvent89SV RAID: Adapter error (Firmware initialization failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28590NodesvraidWinEvent90SV RAID: Adapter error (Firmware recovery failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28591NodesvraidWinEvent91SV RAID: Adapter error (BBU requires reconditioning; please initiate recalibration)
1.3.6.1.4.1.211.1.31.1.2.201.61.28592NodesvraidWinEvent92SV RAID: Software error (Task for object cannot be started. The scheduler has disabled the task)
1.3.6.1.4.1.211.1.31.1.2.201.61.28593NodesvraidWinEvent93SV RAID: Adapter error (SAS topology error)
1.3.6.1.4.1.211.1.31.1.2.201.61.28594NodesvraidWinEvent94SV RAID: Device error (State change on disk from copyback to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28595NodesvraidWinEvent95SV RAID: Device error (State change on disk from copyback to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28596NodesvraidWinEvent96SV RAID: Device error (State change on disk from JBOD to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28597NodesvraidWinEvent97SV RAID: Device error (State change on disk from JBOD to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28598NodesvraidWinEvent98SV RAID: Device error (State change by user on disk from copyback to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28599NodesvraidWinEvent99SV RAID: Device error (State change by user on disk from copyback to offline)
1.3.6.1.4.1.211.1.31.1.2.201.61.28600NodesvraidWinEvent100SV RAID: Device error (State change by user on disk from JBOD to failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28601NodesvraidWinEvent101SV RAID: Adapter error (Disk security failed to communicate with EKMS)
1.3.6.1.4.1.211.1.31.1.2.201.61.28602NodesvraidWinEvent102SV RAID: Adapter error (Logical drive secure failed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28603NodesvraidWinEvent103SV RAID: Adapter error (Controller encountered a fatal error and was reset)
1.3.6.1.4.1.211.1.31.1.2.201.61.28604NodesvraidWinEvent104SV RAID: Device error (Configuration command could not be committed to disk)
1.3.6.1.4.1.211.1.31.1.2.201.61.28605NodesvraidWinEvent105SV RAID: Device error (Power state change failed on disk)
1.3.6.1.4.1.211.1.31.1.2.201.61.28606NodesvraidWinEvent106SV RAID: Device error (Power state change failed on disk (from stopped to active))
1.3.6.1.4.1.211.1.31.1.2.201.61.28607NodesvraidWinEvent107SV RAID: Device error (Logical drive is not ready)
1.3.6.1.4.1.211.1.31.1.2.201.61.28608NodesvraidWinEvent108SV RAID: Adapter error (Adapter has been replaced during reboot)
1.3.6.1.4.1.211.1.31.1.2.201.61.28609NodesvraidWinEvent109SV RAID: Adapter error (Enclosure power supply removed)
1.3.6.1.4.1.211.1.31.1.2.201.61.28610NodesvraidWinEvent110SV RAID: Adapter error (Enclosure power supply turned off)
1.3.6.1.4.1.211.1.31.1.2.201.61.28611NodesvraidWinEvent111SV RAID: Adapter error (Enclosure temperature sensor below warning threshold)
1.3.6.1.4.1.211.1.31.1.2.201.61.28612NodesvraidWinEvent112SV RAID: Adapter error (Enclosure temperature sensor below error threshold)
1.3.6.1.4.1.211.1.31.1.2.201.61.28613NodesvraidWinEvent113SV RAID: Adapter error (Enclosure temperature sensor above warning threshold)
1.3.6.1.4.1.211.1.31.1.2.201.61.28614NodesvraidWinEvent114SV RAID: Adapter error (Enclosure temperature sensor above error threshold)
1.3.6.1.4.1.211.1.31.1.2.201.61.28615NodesvraidWinEvent115SV RAID: Device error (Power state change failed on disk (from active to transition))
1.3.6.1.4.1.211.1.31.1.2.201.61.28616NodesvraidWinEvent116SV RAID: Device error (Power state change failed on disk (from stopped to transition))
1.3.6.1.4.1.211.1.31.1.2.201.61.28617NodesvraidWinEvent117SV RAID: Device error (Power state change failed on disk (from transition to active))
1.3.6.1.4.1.211.1.31.1.2.201.61.28618NodesvraidWinEvent118SV RAID: Device error (Power state change failed on disk (from transition to stopped))
1.3.6.1.4.1.211.1.31.1.2.201.62NodepsaWinMpdTrap
1.3.6.1.4.1.211.1.31.1.2.201.63NodepsaWinGlsTrap
1.3.6.1.4.1.211.1.31.1.2.201.64NodepsaWinIntele1expressTrap
1.3.6.1.4.1.211.1.31.1.2.201.65NodepsaWinIntelixgbnTrap
1.3.6.1.4.1.211.1.31.1.2.201.102NodepsaSVAgentsTrap