MIB Viewer

PowerNet-Discovery-MIB

69 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.3.2NodeapcDiscovery
1.3.6.1.3.2.1ScalarapcDiscoveryInfoTableSizeread-onlymandatoryThe number of APC devices discovered at this IP address.
1.3.6.1.3.2.2TableapcDiscoveryInfoTablenot-accessiblemandatoryAllows for access to discovered device(s) at this IP. The number of entries is contained in the apcDiscoveryInfoTableSize OID.
1.3.6.1.3.2.2.1RowapcDiscoveryInfoEntrynot-accessiblemandatoryThe discovered device to query.
1.3.6.1.3.2.2.1.1ColumnapcDiscoveryInfoTableIndexread-onlymandatoryThe index to the discovered device table entry.
1.3.6.1.3.2.2.1.2ColumnapcDiscoveryModelread-onlymandatoryThe APC device generic model identifier.
1.3.6.1.3.2.2.1.3ColumnapcDiscoverySerialNumberread-onlymandatorySerial Number of the discovered device or sub-device.
1.3.6.1.3.2.2.1.4ColumnapcDiscoveryStatusread-onlymandatoryThe status of the APC device. unknown(1) indicates the state is unknown. deviceNormal(2) indicates the device is functioning normally. deviceWarning(3) indicat…
1.3.6.1.3.2.2.1.5ColumnapcDiscoveryLabelStringread-onlymandatoryThe label of the device to be presented in the ISX Manager discovery interface.
1.3.6.1.3.2.2.1.6ColumnapcDiscoveryDeviceHierarchyread-onlymandatoryThe relative position of the device: Primary (1) the main device (e.g. a UPS) Secondary (2) an additional device (e.g. Integrated Environmental Monitor) Subord…
1.3.6.1.3.2.2.1.7ColumnapcDiscoveryDeviceLocationread-writemandatoryThe user-defined location of the device.
1.3.6.1.3.2.2.1.8ColumnapcDiscoveryDeviceLocationMaxLengthread-onlymandatoryThe maximum length of the user-defined location of the device.
1.3.6.1.3.2.2.1.9ColumnapcDiscoveryDeviceNameread-writemandatoryThe user-defined name of the device.
1.3.6.1.3.2.2.1.10ColumnapcDiscoveryDeviceNameMaxLengthread-onlymandatoryThe maximum length of the user-defined name of the device.
1.3.6.1.3.2.2.1.11ColumnapcDiscoveryDeviceInstanceread-onlymandatoryUnique instance identifier used to distinguish between devices of the same apcDiscoveryModel.
1.3.6.1.3.2.2.1.12ColumnapcDiscoveryDeviceParamsIndexread-onlymandatoryTable reference/index used to access device parameter values.
1.3.6.1.3.2.2.1.13ColumnapcDiscoveryDdfXReferenceread-onlymandatoryCross reference identifier used to locate the DDF file specified in the apcDiscoveryDeviceDefTable table that is appropriate for this device.
1.3.6.1.3.2.2.1.14ColumnapcDiscoveryDeviceStatusBlockIdread-onlymandatoryThe ID of the status block to display for this device.
1.3.6.1.3.2.3ScalarapcDiscoveryDeviceFirmwareTableSizeread-onlymandatoryThe number of firmware elements hosted at this APC device.
1.3.6.1.3.2.4TableapcDiscoveryDeviceFirmwareTablenot-accessiblemandatoryAllows for access to firmware elements on this device. The number of entries is contained in the apcDiscoveryDeviceFirmwareTableSize OID.
1.3.6.1.3.2.4.1RowapcDiscoveryDeviceFirmwareEntrynot-accessiblemandatoryThe firmware element to query.
1.3.6.1.3.2.4.1.1ColumnapcDiscoveryDeviceFirmwareTableIndexread-onlymandatoryThe index to the discovered device table entry.
1.3.6.1.3.2.4.1.2ColumnapcDiscoveryDeviceSerialNumberread-onlymandatorySerial Number of the device that has this firmware.
1.3.6.1.3.2.4.1.3ColumnapcDiscoveryFirmwareNameread-onlymandatoryFirmware name for this firmware.
1.3.6.1.3.2.4.1.4ColumnapcDiscoveryFirmwareRevisionread-onlymandatoryRevision of the firmware.
1.3.6.1.3.2.5ScalarapcDiscoveryDeviceProtocolTableSizeread-onlymandatoryThe number of protocols supported by this device.
1.3.6.1.3.2.6TableapcDiscoveryDeviceProtocolTablenot-accessiblemandatoryAllows for access to protocol entries on this device. Each entry represents a protocol that the device supports. The number of entries is contained in the apcD…
1.3.6.1.3.2.6.1RowapcDiscoveryDeviceProtocolEntrynot-accessiblemandatoryThe protocol element to query.
1.3.6.1.3.2.6.1.1ColumnapcDiscoveryDeviceProtocolTableIndexread-onlymandatoryThe index to the protocol table entry.
1.3.6.1.3.2.6.1.2ColumnapcDiscoveryProtocolNumberread-onlymandatoryProtocol Number. 1-SNMP 2-Telnet 3-HTTP 4-DCAL 5-SDCAL (Secure DCAL) 6-SSL 7-SSH 8-SCP 9-NTP 10-SMTP 11-FTP Server 12-TFTP Client 13-BOOTP 14-DHCP 15-RADIUS 16…
1.3.6.1.3.2.6.1.3ColumnapcDiscoveryProtocolVersionread-onlymandatoryThe version of the protocol.
1.3.6.1.3.2.6.1.4ColumnapcDiscoveryProtocolPortread-onlymandatoryEncoded port on which this protocol is being used.
1.3.6.1.3.2.6.1.5ColumnapcDiscoveryProtocolEnabledDisabledread-onlymandatoryThe enabled/disabled state of the protocol within this device . disabled(1) indicates the protocol is supported, but mandatoryly disabled. enabled(2) indicates…
1.3.6.1.3.2.7ScalarapcDiscoveryDeviceDefTableSizeread-onlymandatoryThe number of DDF files available at this IP address.
1.3.6.1.3.2.8TableapcDiscoveryDeviceDefTablenot-accessiblemandatoryAllows for access to the device definition information for the discovered device(s) at this IP. The number of entries is contained in the apcDiscoveryDeviceDef…
1.3.6.1.3.2.8.1RowapcDiscoveryDeviceDefEntrynot-accessiblemandatoryThe device description element for the device.
1.3.6.1.3.2.8.1.1ColumnapcDiscoveryDeviceDefTableIndexread-onlymandatoryThe index to the device definition table entry.
1.3.6.1.3.2.8.1.2ColumnapcDiscoveryDeviceDefDeviceClassread-onlymandatoryString specifying the device class. Class, Type, Family is used to identify the device described by this DDF file.
1.3.6.1.3.2.8.1.3ColumnapcDiscoveryDeviceDefDeviceTyperead-onlymandatoryString specifying the device type. Class, Type, Family is used to identify the device described by this DDF file.
1.3.6.1.3.2.8.1.4ColumnapcDiscoveryDeviceDefDeviceFamilyread-onlymandatoryString specifying the device family. Class, Type, and Family are used to identify the device described by this DDF file.
1.3.6.1.3.2.8.1.5ColumnapcDiscoveryDeviceDefDeviceVersionread-onlymandatoryA string value specifying the version of the DDF element to be used for this device.
1.3.6.1.3.2.8.1.6ColumnapcDiscoveryDeviceDefDdfXReferenceread-onlymandatoryCross reference identifier used to locate the DDF file from the apcDiscoveryInfoTable table.
1.3.6.1.3.2.9ScalarapcDiscoveryDeviceAlarmStateChangeCountread-onlymandatoryThe number of changes to the alarm state table. This number starts at zero and increases by one for each change to the table.
1.3.6.1.3.2.10ScalarapcDiscoveryDeviceAlarmStateTableSizeread-onlymandatoryThe number of elements in the alarm state table.
1.3.6.1.3.2.11TableapcDiscoveryDeviceAlarmStateTablenot-accessiblemandatoryAllows for access to alarm states reported by the devices at this IP address.
1.3.6.1.3.2.11.1RowapcDiscoveryDeviceAlarmStateEntrynot-accessiblemandatoryThe condition entry.
1.3.6.1.3.2.11.1.1ColumnapcDiscoveryDeviceAlarmStateTableIndexread-onlymandatoryThe index to the alarm state table entry.
1.3.6.1.3.2.11.1.2ColumnapcDiscoveryDeviceAlarmStateSerialNumberread-onlymandatorySerial Number of the device that has the alarm state.
1.3.6.1.3.2.11.1.3ColumnapcDiscoveryDeviceAlarmStateCoderead-onlymandatoryEncoded data string representing mandatory device alarm state. The format of the 12-byte (012345678901) string is as follows: bytes 0-1 : 16-bit alarm code (by…
1.3.6.1.3.2.11.1.4ColumnapcDiscoveryDeviceAlarmStateParamread-onlymandatoryOptional parameter or parameters associated with this alarm state. Parameters are encoded as a sequence of varbinds corresponding to values in the MIB.
1.3.6.1.3.2.12ScalarapcDiscoveryDeviceInfoChangeCountread-onlymandatoryThe number of changes to the device info table. When a device is added or removed this count is incremented.
1.3.6.1.3.4NodeapcTrapReceiver
1.3.6.1.3.4.1ScalarapcTrapRecvTableSizeread-onlymandatoryThe number of trap receivers in apcTrapRecvTable.
1.3.6.1.3.4.2TableapcTrapRecvTablenot-accessiblemandatoryTable of trap receivers.
1.3.6.1.3.4.2.1RowapcTrapRecvEntrynot-accessiblemandatoryTrap receiver table.
1.3.6.1.3.4.2.1.1ColumnapcTrapRecvIndexread-onlymandatoryTrap receiver index.
1.3.6.1.3.4.2.1.2ColumnapcTrapRecvHostread-onlymandatoryThe host name of the manager.
1.3.6.1.3.4.2.1.3ColumnapcTrapRecvTyperead-onlymandatoryThe type of manager.
1.3.6.1.3.4.2.1.4ColumnapcTrapRecvUniqueIdread-onlymandatoryUnique ID obtained from getting the apcTrapReceiverUniqueID OID.
1.3.6.1.3.4.3ScalarapcTrapRecvTableModifyread-writemandatoryAllows the manager to modify the list of trap receivers... 'hostname, Value[, UniqueID]'
1.3.6.1.3.4.4ScalarapcTrapReceiverUniqueIDread-onlymandatoryThis OID returns a unique ID to be used to register for Traps.
1.3.6.1.4.1.318Nodeapc
1.3.6.1.4.1.318.1Nodeproducts
1.3.6.1.4.1.318.1.1Nodehardware
1.3.6.1.4.1.318.1.2Nodesoftware
1.3.6.1.4.1.318.1.3Nodesystem
1.3.6.1.4.1.318.1.4Nodeexperimental
1.3.6.1.4.1.318.2Nodeapcmgmt
1.3.6.1.4.1.318.1000NodeapcDiscoveryAlarmStateTableUpdateINTERNAL: A Discovery Alarm State Table Update trap is sent when any data alarm state is added, removed, or its parameters are changed in the condition table. …