MIB Viewer

RC7586-MIB

113 objects
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
OIDNameAccessStatusDescription
1.3.6.1.4.1.23304.2.2Identityrc7586MIBThe Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
1.3.6.1.4.1.23304.2.2.1Nodebuc1
1.3.6.1.4.1.23304.2.2.1.1Nodebuc1Configuration
1.3.6.1.4.1.23304.2.2.1.1.1Nodebuc1TxSettings
1.3.6.1.4.1.23304.2.2.1.1.1.1Scalarbuc1TxOnread-writecurrentSets Tx on/off. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.1.2Scalarbuc1TxDefaultread-writecurrentSets Tx default 1-last 0-off. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.1.3Scalarbuc1TxAttenuatorread-writecurrentSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.2Nodebuc1PktProtocol
1.3.6.1.4.1.23304.2.2.1.1.2.1Scalarbuc1Protocolread-writecurrentSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.2.2Scalarbuc1Addressread-writecurrentSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.3Nodebuc1RCSetting
1.3.6.1.4.1.23304.2.2.1.1.3.1Scalarbuc1Moderead-writecurrentSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.3.2Scalarbuc1OnLineread-writecurrentSets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.4Nodebuc1Freqs
1.3.6.1.4.1.23304.2.2.1.1.4.1Scalarbuc1RFFreqread-writecurrentSets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.4.2Scalarbuc1IFFreqread-writecurrentSets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.4.3Scalarbuc1LOFreqread-writecurrentSets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.5Nodebuc1Misc
1.3.6.1.4.1.23304.2.2.1.1.5.1Scalarbuc1SerIfread-writecurrentSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.5.2Scalarbuc1PwrAlarmThreshread-writecurrentSets/Gets power alarm threshold. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.5.3Scalarbuc1BurstPwrThreshread-writecurrentSets/Gets burst power threshold. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.5.4Scalarbuc1RefSourceread-writecurrentSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.1.5.5Scalarbuc1LEDStateread-writecurrentSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2Nodebuc1Status
1.3.6.1.4.1.23304.2.2.1.2.1Scalarbuc1PaStatusread-onlycurrentGets to 1 when PA is on. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.2Scalarbuc1TxPowerread-onlycurrentGets Tx power format x.x dB. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.3Scalarbuc1TxBurstPowerread-onlycurrentGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.4Scalarbuc1Faultsread-onlycurrentGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault,…
1.3.6.1.4.1.23304.2.2.1.2.5Scalarbuc1LatchedFaultsread-onlycurrentGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.1.2.6Scalarbuc1Temperatureread-onlycurrentGets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.7Scalarbuc1MinMaxTemperatureread-onlycurrentGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.8Scalarbuc1SystemSettingread-onlycurrentGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - …
1.3.6.1.4.1.23304.2.2.1.2.9Scalarbuc1SystemPollread-onlycurrentGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.10Scalarbuc1DeviceTyperead-onlycurrentGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.11Scalarbuc1Gatewayread-onlycurrentGets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.12Scalarbuc1IpAddressread-onlycurrentGets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.13Scalarbuc1MACAddressread-onlycurrentGets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.14Scalarbuc1Netmaskread-onlycurrentGets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.15Scalarbuc1RefPowerread-onlycurrentGets the BUC reference power. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.16Scalarbuc1Configread-onlycurrentGets the BUC configuration. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.2.17Scalarbuc1BuildStandardread-onlycurrentGets the BUC build standard. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.1.3Nodebuc1Info
1.3.6.1.4.1.23304.2.2.1.3.1Scalarbuc1IdInforead-onlycurrentGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 n…
1.3.6.1.4.1.23304.2.2.1.3.2Scalarbuc1Limitsread-onlycurrentGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. ***…
1.3.6.1.4.1.23304.2.2.1.3.3Scalarbuc1PktProtocolsInforead-onlycurrentGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected.
1.3.6.1.4.1.23304.2.2.2Nodebuc2
1.3.6.1.4.1.23304.2.2.2.1Nodebuc2Configuration
1.3.6.1.4.1.23304.2.2.2.1.1Nodebuc2TxSettings
1.3.6.1.4.1.23304.2.2.2.1.1.1Scalarbuc2TxOnread-writecurrentSets Tx on/off. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.1.2Scalarbuc2TxDefaultread-writecurrentSets Tx default 1-last 0-off. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.1.3Scalarbuc2TxAttenuatorread-writecurrentSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.2Nodebuc2PktProtocol
1.3.6.1.4.1.23304.2.2.2.1.2.1Scalarbuc2Protocolread-writecurrentSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.2.2Scalarbuc2Addressread-writecurrentSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.3Nodebuc2RCSetting
1.3.6.1.4.1.23304.2.2.2.1.3.1Scalarbuc2Moderead-writecurrentSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.3.2Scalarbuc2OnLineread-writecurrentSets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.4Nodebuc2Freqs
1.3.6.1.4.1.23304.2.2.2.1.4.1Scalarbuc2RFFreqread-writecurrentSets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.4.2Scalarbuc2IFFreqread-writecurrentSets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.4.3Scalarbuc2LOFreqread-writecurrentSets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.5Nodebuc2Misc
1.3.6.1.4.1.23304.2.2.2.1.5.1Scalarbuc2SerIfread-writecurrentSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.5.2Scalarbuc2PwrAlarmThreshread-writecurrentSets/Gets power alarm threshold. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.5.3Scalarbuc2BurstPwrThreshread-writecurrentSets/Gets burst power threshold. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.5.4Scalarbuc2RefSourceread-writecurrentSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.1.5.5Scalarbuc2LEDStateread-writecurrentSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2Nodebuc2Status
1.3.6.1.4.1.23304.2.2.2.2.1Scalarbuc2PaStatusread-onlycurrentGets to 1 when PA is on. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.2Scalarbuc2TxPowerread-onlycurrentGets Tx power format x.x dB. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.3Scalarbuc2TxBurstPowerread-onlycurrentGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.4Scalarbuc2Faultsread-onlycurrentGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault,…
1.3.6.1.4.1.23304.2.2.2.2.5Scalarbuc2LatchedFaultsread-onlycurrentGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.6Scalarbuc2Temperatureread-onlycurrentGets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.7Scalarbuc2MinMaxTemperatureread-onlycurrentGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.8Scalarbuc2SystemSettingread-onlycurrentGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - …
1.3.6.1.4.1.23304.2.2.2.2.9Scalarbuc2SystemPollread-onlycurrentGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.10Scalarbuc2DeviceTyperead-onlycurrentGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.11Scalarbuc2Gatewayread-onlycurrentGets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.12Scalarbuc2IpAddressread-onlycurrentGets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.13Scalarbuc2MACAddressread-onlycurrentGets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.14Scalarbuc2Netmaskread-onlycurrentGets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.15Scalarbuc2RefPowerread-onlycurrentGets the BUC reference power. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.16Scalarbuc2Configread-onlycurrentGets the BUC configuration. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.2.17Scalarbuc2BuildStandardread-onlycurrentGets the BUC build standard. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.2.3Nodebuc2Info
1.3.6.1.4.1.23304.2.2.2.3.1Scalarbuc2IdInforead-onlycurrentGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 n…
1.3.6.1.4.1.23304.2.2.2.3.2Scalarbuc2Limitsread-onlycurrentGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. ***…
1.3.6.1.4.1.23304.2.2.2.3.3Scalarbuc2PktProtocolsInforead-onlycurrentGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected.
1.3.6.1.4.1.23304.2.2.3Nodectrl
1.3.6.1.4.1.23304.2.2.3.1Nodesettings
1.3.6.1.4.1.23304.2.2.3.1.1ScalaroperationalModeread-writecurrentSets 7586 operational mode - Auto, Manual Stream1, Stream2.
1.3.6.1.4.1.23304.2.2.3.1.2ScalaronlineStreamread-writecurrentSets the online stream.
1.3.6.1.4.1.23304.2.2.3.1.3ScalarwaveguideSwitchread-writecurrentSets Waveguide switch Rx+Tx, Rx/Tx and Tx Only.
1.3.6.1.4.1.23304.2.2.3.1.4ScalarstartupTimeread-writecurrentSets Startup time.
1.3.6.1.4.1.23304.2.2.3.1.5ScalarlnbCurrentLimitread-writecurrentSets LNB current limits.
1.3.6.1.4.1.23304.2.2.3.1.6ScalarledStateread-writecurrentSets 7586 LED.
1.3.6.1.4.1.23304.2.2.3.1.7ScalarrefSourceread-writecurrentSets 7586 reference state.
1.3.6.1.4.1.23304.2.2.3.1.8ScalarrefTrimread-writecurrentSets 7586 reference trim.
1.3.6.1.4.1.23304.2.2.3.1.9ScalarrefThreshread-writecurrentSets 7586 reference alarm treshold.
1.3.6.1.4.1.23304.2.2.3.1.10ScalarrefPwrread-onlycurrentGets 7586 reference power.
1.3.6.1.4.1.23304.2.2.3.1.11ScalaripAddrread-onlycurrentGets the 7586 IP address.
1.3.6.1.4.1.23304.2.2.3.1.12ScalarmacAddressread-onlycurrentGets the 7586 MAC address.
1.3.6.1.4.1.23304.2.2.3.1.13Scalarnetmaskread-onlycurrentGets the 7586 netmask.
1.3.6.1.4.1.23304.2.2.3.1.14Scalargatewayread-onlycurrentGets the 7586 gateway address.
1.3.6.1.4.1.23304.2.2.3.2Nodestatus
1.3.6.1.4.1.23304.2.2.3.2.1ScalarlnbCurrentread-onlycurrentSets 7586 LNB current.
1.3.6.1.4.1.23304.2.2.3.2.2ScalarlnbVoltageread-onlycurrentSets 7586 LNB voltage.
1.3.6.1.4.1.23304.2.2.3.2.3Scalarfaultsread-onlycurrentGets the current fault status.
1.3.6.1.4.1.23304.2.2.3.3Nodeinfo
1.3.6.1.4.1.23304.2.2.3.3.1ScalaridInforead-onlycurrentGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.
Type Definitions
NameSyntaxStatusDescription
ComponentRevisionDisplayString(SIZE(2))currentThe hex value in the first octet - xx - represents the major revision no. and the hex value in the second octet - yy - represents the minor revision no.
FaultStatus7586BITS { dc1fault(0), dc2fault(1), buc1fault(2), buc2fault(3), lnb1fault(4), lnb2fault(5), txswfault(6), rxswfault(7), internalfault(8), ref10mhzfault(9) }currentDescribes all the possible faults in the system as a bit pattern.