MIB Viewer

RS232-MIB

41 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.3.20Noders232
1.3.6.1.3.20.1Scalarrs232Numberread-onlymandatoryThe number of ports (regardless of their current state) in the RS-232-like general port table.
1.3.6.1.3.20.2Tablers232PortTablenot-accessiblemandatoryA list of port entries. The number of entries is given by the value of rs232Number.
1.3.6.1.3.20.2.1Rowrs232PortEntrynot-accessiblemandatoryStatus and parameter values for a port.
1.3.6.1.3.20.2.1.1Columnrs232PortIndexread-onlymandatoryA unique value for each port. Its value ranges between 1 and the value of rs232Number. By convention and if possible, hardware port numbers map directly to ext…
1.3.6.1.3.20.2.1.2Columnrs232PortTyperead-onlymandatoryThe port's hardware type.
1.3.6.1.3.20.2.1.3Columnrs232PortInSigNumberread-onlymandatoryThe number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can de…
1.3.6.1.3.20.2.1.4Columnrs232PortOutSigNumberread-onlymandatoryThe number of output signals for the port in the output signal table (rs232PortOutSigTable). The table contains entries only for those signals the software can…
1.3.6.1.3.20.2.1.5Columnrs232PortInSpeedread-writemandatoryThe port's input speed in bits per second.
1.3.6.1.3.20.2.1.6Columnrs232PortOutSpeedread-writemandatoryThe port's output speed in bits per second.
1.3.6.1.3.20.3Tablers232AsyncPortTablenot-accessiblemandatoryA list of asynchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for synchronous ports.
1.3.6.1.3.20.3.1Rowrs232AsyncPortEntrynot-accessiblemandatoryStatus and parameter values for an asynchronous port.
1.3.6.1.3.20.3.1.1Columnrs232AsyncPortIndexread-onlymandatoryA unique value for each port. Its value is the same as rs232PortIndex for the port.
1.3.6.1.3.20.3.1.2Columnrs232AsyncPortBitsread-writemandatoryThe port's number of bits in a character.
1.3.6.1.3.20.3.1.3Columnrs232AsyncPortStopBitsread-writemandatoryThe port's number of stop bits.
1.3.6.1.3.20.3.1.4Columnrs232AsyncPortParityread-writemandatoryThe port's sense of a character parity bit.
1.3.6.1.3.20.3.1.5Columnrs232AsyncPortAutobaudread-writemandatoryA control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set …
1.3.6.1.3.20.3.1.6Columnrs232AsyncPortParityErrsread-onlymandatoryTotal number of characters with a parity error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
1.3.6.1.3.20.3.1.7Columnrs232AsyncPortFramingErrsread-onlymandatoryTotal number of characters with a framing error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
1.3.6.1.3.20.3.1.8Columnrs232AsyncPortOverrunErrsread-onlymandatoryTotal number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
1.3.6.1.3.20.4Tablers232SyncPortTablenot-accessiblemandatoryA list of synchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for asynchronous ports.
1.3.6.1.3.20.4.1Rowrs232SyncPortEntrynot-accessiblemandatoryStatus and parameter values for a synchronous port.
1.3.6.1.3.20.4.1.1Columnrs232SyncPortIndexread-onlymandatoryA unique value for each port. Its value is the same as rs232PortIndex for the port.
1.3.6.1.3.20.4.1.2Columnrs232SyncPortClockSourceread-writemandatorySource of the port's bit rate clock. 'split' means the tranmit clock is internal and the receive clock is external.
1.3.6.1.3.20.4.1.3Columnrs232SyncPortFrameCheckErrsread-onlymandatoryTotal number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'.
1.3.6.1.3.20.4.1.4Columnrs232SyncPortTransmitUnderrunErrsread-onlymandatoryTotal number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was no…
1.3.6.1.3.20.4.1.5Columnrs232SyncPortReceiveOverrunErrsread-onlymandatoryTotal number of frames that failed to be received on the port since system re-initialization and while the port state was 'up' or 'test' because the receiver d…
1.3.6.1.3.20.4.1.6Columnrs232SyncPortInterruptedFramesread-onlymandatoryTotal number of frames that failed to be received or transmitted on the port due to loss of modem signals since system re-initialization and while the port sta…
1.3.6.1.3.20.4.1.7Columnrs232SyncPortAbortedFramesread-onlymandatoryNumber of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'.
1.3.6.1.3.20.5Tablers232InSigTablenot-accessiblemandatoryA list of port input control signal entries.
1.3.6.1.3.20.5.1Rowrs232InSigEntrynot-accessiblemandatoryInput control signal status for a hardware port.
1.3.6.1.3.20.5.1.1Columnrs232InSigPortIndexread-onlymandatoryThe value of rs232PortIndex for the port to which this entry belongs.
1.3.6.1.3.20.5.1.2Columnrs232InSigNameread-onlymandatoryIdentification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Receive…
1.3.6.1.3.20.5.1.3Columnrs232InSigStateread-onlymandatoryThe current signal state.
1.3.6.1.3.20.5.1.4Columnrs232InSigChangesread-onlymandatoryThe number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
1.3.6.1.3.20.6Tablers232OutSigTablenot-accessiblemandatoryA list of port output control signal entries.
1.3.6.1.3.20.6.1Rowrs232OutSigEntrynot-accessiblemandatoryOutput control signal status for a hardware port.
1.3.6.1.3.20.6.1.1Columnrs232OutSigPortIndexread-onlymandatoryThe value of rs232PortIndex for the port to which this entry belongs.
1.3.6.1.3.20.6.1.2Columnrs232OutSigNameread-onlymandatoryIdentification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Receive…
1.3.6.1.3.20.6.1.3Columnrs232OutSigStateread-onlymandatoryThe current signal state.
1.3.6.1.3.20.6.1.4Columnrs232OutSigChangesread-onlymandatoryThe number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.