RUGGEDCOM-IRIGB-MIB
30 objects
Siemens - RuggedCom proprietary to control and monitor IRIGB module.
Imported Objects
| RUGGEDCOM-MIB | ruggedcomMgmt ruggedcomTraps |
| RUGGEDCOM-TIMECONFIG-MIB | RcTimeSyncStatus |
| SNMPv2-CONF | OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.15004.4.10 | IdentityrcIrigb | Siemens - RuggedCom proprietary to control and monitor IRIGB module. | ||
| 1.3.6.1.4.1.15004.4.10.1 | NodercIrigbBase | |||
| 1.3.6.1.4.1.15004.4.10.1.1 | ScalarrcIrigbStatus | read-only | current | The system synchronization status when IRIGB is a primary time source. If value of this object is changed, rcIrigbStatusChange notification will be sent. |
| 1.3.6.1.4.1.15004.4.10.1.2 | ScalarrcIrigbAMOutput | read-write | current | Selects AM (Amplitude Modulation) mode of IRIGB port. |
| 1.3.6.1.4.1.15004.4.10.1.3 | ScalarrcIrigbTimeCode | read-write | current | This device uses the following convention to decode the IRIGB time code: letter [B] represents IRIG-B format, [xx] represents [00] for PWM/TTL mode of operatio… |
| 1.3.6.1.4.1.15004.4.10.1.4 | ScalarrcIrigbExt | read-write | current | IRIGB extensions use extra bits of the Control Functions (CF) portion of the IRIGB time code. Within this portion of the time code, bits are designated for add… |
| 1.3.6.1.4.1.15004.4.10.1.5 | ScalarrcIrigbInput | read-write | current | Selects operational mode of IRIGB input port. IRIGB module is capable of interpreting IRIGB extensions such as C37.118-2011, C37.118-2005 and IEEE1344. |
| 1.3.6.1.4.1.15004.4.10.1.6 | ScalarrcIrigbLockInt | read-write | current | To set time interval in minute with in which IRIGB receiver should acquire lock to the time source. Normally IRIGB receiver needs couple of minutes to lock the… |
| 1.3.6.1.4.1.15004.4.10.1.7 | ScalarrcIrigbCableComp | read-write | current | Cable compensation in ns may be desired to compensate for a long cable run in order to minimize the timing inaccuracy. |
| 1.3.6.1.4.1.15004.4.10.1.8 | ScalarrcIrigbOFM | read-only | current | The current time offset between system and reference clocks. |
| 1.3.6.1.4.1.15004.4.10.1.9 | ScalarrcIrigbFreqAdj | read-only | current | The current amount of discipline applied to the local frequency reference (TCXO). |
| 1.3.6.1.4.1.15004.4.10.1.10 | ScalarrcIrigbOutputPWM1 | read-write | current | Selects Operational mode of TTL output port. PWM mode complies with IRIG Standard 200-04. PPx provides generic pulse per x second interface to synchronize exte… |
| 1.3.6.1.4.1.15004.4.10.1.11 | ScalarrcIrigbPulseInterval1 | read-write | current | Selects Pulse Interval in s for TTL output port. This parameter is used in conjunction with PPx in order to provides generic pulse per x second interface to sy… |
| 1.3.6.1.4.1.15004.4.10.1.12 | ScalarrcIrigbPulseWidth1 | read-write | current | Selects Pulse Width in ms for TTL output port. This parameter is used in conjunction with PPx to control the width of the pulse. |
| 1.3.6.1.4.1.15004.4.10.1.13 | ScalarrcIrigbStartTime1 | read-write | current | This parameter is used in conjunction with PPx to set the starting time of first PPx event. Note that this parameter must be set at least 15 seconds before the… |
| 1.3.6.1.4.1.15004.4.10.1.14 | ScalarrcIrigbOutputPWM2 | read-write | current | Selects Operational mode of TTL output port2. PWM mode complies with IRIG Standard 200-04. PPx provides generic pulse per x second interface to synchronize ext… |
| 1.3.6.1.4.1.15004.4.10.1.15 | ScalarrcIrigbPulseInterval2 | read-write | current | Selects Pulse Interval in s for TTL output port2. This parameter is used in conjunction with PPx in order to provides generic pulse per x second interface to s… |
| 1.3.6.1.4.1.15004.4.10.1.16 | ScalarrcIrigbPulseWidth2 | read-write | current | Selects Pulse Width in ms for TTL output port2. This parameter is used in conjunction with PPx to control the width of the pulse. |
| 1.3.6.1.4.1.15004.4.10.1.17 | ScalarrcIrigbStartTime2 | read-write | current | This parameter is used in conjunction with PPx to set the starting time of first PPx event. Note that this parameter must be set at least 15 seconds before the… |
| 1.3.6.1.4.1.15004.4.10.2 | NodercIrigbConformance | |||
| 1.3.6.1.4.1.15004.4.10.2.2 | NodercIrigbGroups | |||
| 1.3.6.1.4.1.15004.4.10.2.2.1 | GrouprcIrigbBaseGroup | current | A group of objects providing ability ability to monitor and configure IRIGB status. | |
| 1.3.6.1.4.1.15004.4.10.2.2.2 | GrouprcIrigbNotifyGroup | current | A group of objects that define trap. | |
| 1.3.6.1.4.1.15004.4.10.2.2.3 | GrouprcIrigbCommonGroup | current | A group of objects providing ability to monitor and configure IRIGB device. | |
| 1.3.6.1.4.1.15004.4.10.2.2.4 | GrouprcIrigbAMOutGroup | current | A group of objects providing ability to configure IRIGB AM output interface. | |
| 1.3.6.1.4.1.15004.4.10.2.2.5 | GrouprcIrigbInputGroup | current | This parameter covers both AM and PWM inputs. | |
| 1.3.6.1.4.1.15004.4.10.2.2.6 | GrouprcIrigbTTLOutput01Group | current | A group of objects providing ability to configure IRIGB TTL output interface01. | |
| 1.3.6.1.4.1.15004.4.10.2.2.7 | GrouprcIrigbTTLOutput02Group | current | A group of objects providing ability to configure IRIGB TTL output interface02. | |
| 1.3.6.1.4.1.15004.5.35 | NotificationrcIrigbStatusChange | current | Notification generated if status of the IRIGB module is changed. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| RcTimeStamp | OCTET STRING (SIZE (8)) | current | Timestamps are represented as a 64-bit unsigned fixed-point number in seconds relative to 00:00 on 1 January 1970. The integer part is in the first 32 bits and the fraction part is in the last 32 bits. |