RUGGEDCOM-SFP-DDM-MIB
55 objects
RuggedCom proprietary to monitor SFP DDM information.
Imported Objects
| RUGGEDCOM-MIB | ruggedcomMgmt ruggedcomTraps |
| SNMPv2-CONF | OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.15004.4.17 | IdentityrcSfpDdm | RuggedCom proprietary to monitor SFP DDM information. | ||
| 1.3.6.1.4.1.15004.4.17.1 | NodercSfpDdmGlobalConfig | |||
| 1.3.6.1.4.1.15004.4.17.1.1 | ScalarrcSfpDdmPollingInterval | read-write | current | The time interval in minutes to wait between two consecutive readings from SFP/SFP+ transceivers installed. When this interval is set to 0, the SFP DDM feature… |
| 1.3.6.1.4.1.15004.4.17.2 | NodercSfpDdmTables | |||
| 1.3.6.1.4.1.15004.4.17.2.1 | TablercSfpDdmPortTable | not-accessible | current | A list of SFP DDM port entries. |
| 1.3.6.1.4.1.15004.4.17.2.1.1 | RowrcSfpDdmPortEntry | not-accessible | current | SFP DDM parameters for an SFP port. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.1 | ColumnrcSfpPortId | not-accessible | current | The SFP port identifier for which this entry contains information. The value is limited by number of SFP ports on the device. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.2 | ColumnrcSfpPlugged | read-only | current | SFP transceiver is plugged or not. true(1) is plugged and false(2) is unplugged. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.3 | ColumnrcSfpDdmVendorName | read-only | current | The vendor's name of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.4 | ColumnrcSfpDdmVendorPartNumber | read-only | current | The vendor's part number of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.5 | ColumnrcSfpDdmVendorRevision | read-only | current | The vendor's revision of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.6 | ColumnrcSfpDdmVendorSerialNumber | read-only | current | The vendor's serial number of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.7 | ColumnrcSfpDdmEncoding | read-only | current | The encoding mechanism of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.8 | ColumnrcSfpDdmNominalBitrate | read-only | current | The nominal bit rate of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.9 | ColumnrcSfpDdmConnectorType | read-only | current | The connector type of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.10 | ColumnrcSfpDdmWavelength | read-only | current | The laser wavelength of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.11 | ColumnrcSfpDdmLinkLength | read-only | current | The link length of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.12 | ColumnrcSfpDdmImplemented | read-only | current | SFP DDM is implemented on the SFP transceiver or not. true(1) is implemented and false(2) is not implemented. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.13 | ColumnrcSfpDdmCurrentStatus | read-only | current | The current alarm and warning status of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.14 | ColumnrcSfpDdmCurrentTemperature | read-only | current | The current temperature (in units of 0.001 degrees Celsius) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.15 | ColumnrcSfpDdmThreshTempAlarmLow | read-only | current | The threshold of low temperature alarm (in units of 0.001 degrees Celsius) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.16 | ColumnrcSfpDdmThreshTempWarnLow | read-only | current | The threshold of low temperature warning (in units of 0.001 degrees Celsius) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.17 | ColumnrcSfpDdmThreshTempWarnHigh | read-only | current | The threshold of high temperature warning (in units of 0.001 degrees Celsius) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.18 | ColumnrcSfpDdmThreshTempAlarmHigh | read-only | current | The threshold of high temperature alarm (in units of 0.001 degrees Celsius) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.19 | ColumnrcSfpDdmCurrentVoltage | read-only | current | The current voltage (in millivolts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.20 | ColumnrcSfpDdmThreshVoltageAlarmLow | read-only | current | The threshold of low voltage alarm (in millivolts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.21 | ColumnrcSfpDdmThreshVoltageWarnLow | read-only | current | The threshold of low voltage warning (in millivolts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.22 | ColumnrcSfpDdmThreshVoltageWarnHigh | read-only | current | The threshold of high voltage warning (in millivolts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.23 | ColumnrcSfpDdmThreshVoltageAlarmHigh | read-only | current | The threshold of high voltage alarm (in millivolts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.24 | ColumnrcSfpDdmCurrentTxBiasCurrent | read-only | current | The current Tx bias current (in microamperes) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.25 | ColumnrcSfpDdmThreshTxBiasAlarmLow | read-only | current | The threshold of low Tx bias current alarm (in microamperes) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.26 | ColumnrcSfpDdmThreshTxBiasWarnLow | read-only | current | The threshold of low Tx bias current warning (in microamperes) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.27 | ColumnrcSfpDdmThreshTxBiasWarnHigh | read-only | current | The threshold of high Tx bias current warning (in microamperes) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.28 | ColumnrcSfpDdmThreshTxBiasAlarmHigh | read-only | current | The threshold of high Tx bias current alarm (in microamperes) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.29 | ColumnrcSfpDdmCurrentRxPower | read-only | current | The current Rx power (in nanowatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.30 | ColumnrcSfpDdmThreshRxPowerAlarmLow | read-only | current | The threshold of low Rx power alarm (in nanowatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.31 | ColumnrcSfpDdmThreshRxPowerWarnLow | read-only | current | The threshold of low Rx power warning (in nanowatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.32 | ColumnrcSfpDdmThreshRxPowerWarnHigh | read-only | current | The threshold of high Rx power warning (in nanowatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.33 | ColumnrcSfpDdmThreshRxPowerAlarmHigh | read-only | current | The threshold of high Rx power alarm (in nanowatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.34 | ColumnrcSfpDdmCurrentTxPower | read-only | current | The current Tx power (in microwatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.35 | ColumnrcSfpDdmThreshTxPowerAlarmLow | read-only | current | The threshold of low Tx power alarm (in microwatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.36 | ColumnrcSfpDdmThreshTxPowerWarnLow | read-only | current | The threshold of low Tx power warning (in microwatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.37 | ColumnrcSfpDdmThreshTxPowerWarnHigh | read-only | current | The threshold of high Tx power warning (in microwatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.38 | ColumnrcSfpDdmThreshTxPowerAlarmHigh | read-only | current | The threshold of high Tx power alarm (in microwatts) of the SFP transceiver. |
| 1.3.6.1.4.1.15004.4.17.2.1.1.39 | ColumnrcSfpDdmWarningFlags | read-only | current | Warning flags indicate if any of the monitored parameters exceeds its warning threshold or not. The change in the value of any of these bits will generate a wa… |
| 1.3.6.1.4.1.15004.4.17.2.1.1.40 | ColumnrcSfpDdmAlarmFlags | read-only | current | Alarm flags indicate if any of the monitored parameters exceeds its alarm threshold or not. The change in the value of any of these bits will generate an alarm… |
| 1.3.6.1.4.1.15004.4.17.3 | NodercSfpDdmConformance | |||
| 1.3.6.1.4.1.15004.4.17.3.2 | NodercSfpDdmGroups | |||
| 1.3.6.1.4.1.15004.4.17.3.2.1 | GrouprcSfpDdmCfgGroup | current | A group of objects of SFP DDM configurable parameters. | |
| 1.3.6.1.4.1.15004.4.17.3.2.2 | GrouprcSfpDdmTableGroup | current | A group of objects providing information about SFP DDM. | |
| 1.3.6.1.4.1.15004.4.17.3.2.3 | GrouprcSfpDdmNotifyGroup | current | A group of objects that define SFP DDM traps. | |
| 1.3.6.1.4.1.15004.5.52 | NoderuggedcomSfpDdmTraps | |||
| 1.3.6.1.4.1.15004.5.52.1 | NotificationrcSfpDdmWarningTrap | current | An SFP DDM warning trap indicates that at least one of the warning flags is set or cleared on the SFP transceiver. | |
| 1.3.6.1.4.1.15004.5.52.2 | NotificationrcSfpDdmAlarmTrap | current | An SFP DDM alarm trap indicates that at least one of the alarm flags is set or cleared on the SFP transceiver. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| RcSfpDdmAlarmWarnStatus | INTEGER { notAvailable(1), ok(2), warning(3), alarm(4) } | current | DDM alarm and warning status of an SFP transceiver. |