MIB Viewer

RUGGEDCOM-SFP-DDM-MIB

55 objects
RuggedCom proprietary to monitor SFP DDM information.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.15004.4.17IdentityrcSfpDdmRuggedCom proprietary to monitor SFP DDM information.
1.3.6.1.4.1.15004.4.17.1NodercSfpDdmGlobalConfig
1.3.6.1.4.1.15004.4.17.1.1ScalarrcSfpDdmPollingIntervalread-writecurrentThe time interval in minutes to wait between two consecutive readings from SFP/SFP+ transceivers installed. When this interval is set to 0, the SFP DDM feature…
1.3.6.1.4.1.15004.4.17.2NodercSfpDdmTables
1.3.6.1.4.1.15004.4.17.2.1TablercSfpDdmPortTablenot-accessiblecurrentA list of SFP DDM port entries.
1.3.6.1.4.1.15004.4.17.2.1.1RowrcSfpDdmPortEntrynot-accessiblecurrentSFP DDM parameters for an SFP port.
1.3.6.1.4.1.15004.4.17.2.1.1.1ColumnrcSfpPortIdnot-accessiblecurrentThe SFP port identifier for which this entry contains information. The value is limited by number of SFP ports on the device.
1.3.6.1.4.1.15004.4.17.2.1.1.2ColumnrcSfpPluggedread-onlycurrentSFP transceiver is plugged or not. true(1) is plugged and false(2) is unplugged.
1.3.6.1.4.1.15004.4.17.2.1.1.3ColumnrcSfpDdmVendorNameread-onlycurrentThe vendor's name of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.4ColumnrcSfpDdmVendorPartNumberread-onlycurrentThe vendor's part number of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.5ColumnrcSfpDdmVendorRevisionread-onlycurrentThe vendor's revision of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.6ColumnrcSfpDdmVendorSerialNumberread-onlycurrentThe vendor's serial number of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.7ColumnrcSfpDdmEncodingread-onlycurrentThe encoding mechanism of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.8ColumnrcSfpDdmNominalBitrateread-onlycurrentThe nominal bit rate of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.9ColumnrcSfpDdmConnectorTyperead-onlycurrentThe connector type of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.10ColumnrcSfpDdmWavelengthread-onlycurrentThe laser wavelength of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.11ColumnrcSfpDdmLinkLengthread-onlycurrentThe link length of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.12ColumnrcSfpDdmImplementedread-onlycurrentSFP DDM is implemented on the SFP transceiver or not. true(1) is implemented and false(2) is not implemented.
1.3.6.1.4.1.15004.4.17.2.1.1.13ColumnrcSfpDdmCurrentStatusread-onlycurrentThe current alarm and warning status of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.14ColumnrcSfpDdmCurrentTemperatureread-onlycurrentThe current temperature (in units of 0.001 degrees Celsius) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.15ColumnrcSfpDdmThreshTempAlarmLowread-onlycurrentThe threshold of low temperature alarm (in units of 0.001 degrees Celsius) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.16ColumnrcSfpDdmThreshTempWarnLowread-onlycurrentThe threshold of low temperature warning (in units of 0.001 degrees Celsius) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.17ColumnrcSfpDdmThreshTempWarnHighread-onlycurrentThe threshold of high temperature warning (in units of 0.001 degrees Celsius) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.18ColumnrcSfpDdmThreshTempAlarmHighread-onlycurrentThe threshold of high temperature alarm (in units of 0.001 degrees Celsius) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.19ColumnrcSfpDdmCurrentVoltageread-onlycurrentThe current voltage (in millivolts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.20ColumnrcSfpDdmThreshVoltageAlarmLowread-onlycurrentThe threshold of low voltage alarm (in millivolts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.21ColumnrcSfpDdmThreshVoltageWarnLowread-onlycurrentThe threshold of low voltage warning (in millivolts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.22ColumnrcSfpDdmThreshVoltageWarnHighread-onlycurrentThe threshold of high voltage warning (in millivolts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.23ColumnrcSfpDdmThreshVoltageAlarmHighread-onlycurrentThe threshold of high voltage alarm (in millivolts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.24ColumnrcSfpDdmCurrentTxBiasCurrentread-onlycurrentThe current Tx bias current (in microamperes) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.25ColumnrcSfpDdmThreshTxBiasAlarmLowread-onlycurrentThe threshold of low Tx bias current alarm (in microamperes) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.26ColumnrcSfpDdmThreshTxBiasWarnLowread-onlycurrentThe threshold of low Tx bias current warning (in microamperes) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.27ColumnrcSfpDdmThreshTxBiasWarnHighread-onlycurrentThe threshold of high Tx bias current warning (in microamperes) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.28ColumnrcSfpDdmThreshTxBiasAlarmHighread-onlycurrentThe threshold of high Tx bias current alarm (in microamperes) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.29ColumnrcSfpDdmCurrentRxPowerread-onlycurrentThe current Rx power (in nanowatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.30ColumnrcSfpDdmThreshRxPowerAlarmLowread-onlycurrentThe threshold of low Rx power alarm (in nanowatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.31ColumnrcSfpDdmThreshRxPowerWarnLowread-onlycurrentThe threshold of low Rx power warning (in nanowatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.32ColumnrcSfpDdmThreshRxPowerWarnHighread-onlycurrentThe threshold of high Rx power warning (in nanowatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.33ColumnrcSfpDdmThreshRxPowerAlarmHighread-onlycurrentThe threshold of high Rx power alarm (in nanowatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.34ColumnrcSfpDdmCurrentTxPowerread-onlycurrentThe current Tx power (in microwatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.35ColumnrcSfpDdmThreshTxPowerAlarmLowread-onlycurrentThe threshold of low Tx power alarm (in microwatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.36ColumnrcSfpDdmThreshTxPowerWarnLowread-onlycurrentThe threshold of low Tx power warning (in microwatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.37ColumnrcSfpDdmThreshTxPowerWarnHighread-onlycurrentThe threshold of high Tx power warning (in microwatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.38ColumnrcSfpDdmThreshTxPowerAlarmHighread-onlycurrentThe threshold of high Tx power alarm (in microwatts) of the SFP transceiver.
1.3.6.1.4.1.15004.4.17.2.1.1.39ColumnrcSfpDdmWarningFlagsread-onlycurrentWarning flags indicate if any of the monitored parameters exceeds its warning threshold or not. The change in the value of any of these bits will generate a wa…
1.3.6.1.4.1.15004.4.17.2.1.1.40ColumnrcSfpDdmAlarmFlagsread-onlycurrentAlarm flags indicate if any of the monitored parameters exceeds its alarm threshold or not. The change in the value of any of these bits will generate an alarm…
1.3.6.1.4.1.15004.4.17.3NodercSfpDdmConformance
1.3.6.1.4.1.15004.4.17.3.2NodercSfpDdmGroups
1.3.6.1.4.1.15004.4.17.3.2.1GrouprcSfpDdmCfgGroupcurrentA group of objects of SFP DDM configurable parameters.
1.3.6.1.4.1.15004.4.17.3.2.2GrouprcSfpDdmTableGroupcurrentA group of objects providing information about SFP DDM.
1.3.6.1.4.1.15004.4.17.3.2.3GrouprcSfpDdmNotifyGroupcurrentA group of objects that define SFP DDM traps.
1.3.6.1.4.1.15004.5.52NoderuggedcomSfpDdmTraps
1.3.6.1.4.1.15004.5.52.1NotificationrcSfpDdmWarningTrapcurrentAn SFP DDM warning trap indicates that at least one of the warning flags is set or cleared on the SFP transceiver.
1.3.6.1.4.1.15004.5.52.2NotificationrcSfpDdmAlarmTrapcurrentAn SFP DDM alarm trap indicates that at least one of the alarm flags is set or cleared on the SFP transceiver.
Type Definitions
NameSyntaxStatusDescription
RcSfpDdmAlarmWarnStatusINTEGER { notAvailable(1), ok(2), warning(3), alarm(4) }currentDDM alarm and warning status of an SFP transceiver.