MIB Viewer

SALIX-SYSTEM-MIB

40 objects
The MIB describing System Objects for SALIX products. These objects include error reporting objects, and other system information objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.2158.2.3IdentitysalixSystemMIBThe MIB describing System Objects for SALIX products. These objects include error reporting objects, and other system information objects
1.3.6.1.4.1.2158.2.3.1NodesalixSystemMIBObjects
1.3.6.1.4.1.2158.2.3.1.1ScalarsalixSysLastLogErrorNumberread-onlycurrentThe error number that is associate with the last set request.
1.3.6.1.4.1.2158.2.3.1.2ScalarsalixSysLastLogErrorMessageread-onlycurrentThe error message that describes the error associated with the last set request.
1.3.6.1.4.1.2158.2.3.1.3ScalarsalixSysLastLogErrorOidread-onlycurrentThe last set request OID that produced an error.
1.3.6.1.4.1.2158.2.3.1.4ScalarsalixSysTemperatureread-onlydeprecatedThe temperature in degrees Celsius inside the chassis.
1.3.6.1.4.1.2158.2.3.1.5NodesalixSystemSync
1.3.6.1.4.1.2158.2.3.1.5.1ScalarsalixSysSyncTimingModeread-writecurrentAn identification of the source from which timing is derived by the working sync module. Possible values are: internal(1) - the internal oscillator on the sync…
1.3.6.1.4.1.2158.2.3.1.5.2ScalarsalixSysSyncPrimaryRefread-writecurrentThe interface index of the primary reference line from which the sync module can derive timing. If the 'salixSysSyncTimingMode' is set to 'line' then this inte…
1.3.6.1.4.1.2158.2.3.1.5.3ScalarsalixSysSyncSecondaryRefread-writecurrentThe interface index of the secondary reference line from which the sync module can derive timing. If the 'salixSysSyncTimingMode' is set to 'line' then this in…
1.3.6.1.4.1.2158.2.3.1.5.4ScalarsalixSysSyncRevertiveSwitchread-writecurrentIndication of whether or not the active interface for deriving timing should revert to the interface defined by the primary reference line 'salixSysSyncPrimary…
1.3.6.1.4.1.2158.2.3.1.5.5ScalarsalixSysSyncClockModeread-onlycurrentIndication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's internal oscillator. normal(2) …
1.3.6.1.4.1.2158.2.3.1.5.6ScalarsalixSysSyncConfiguredActiveRefread-writecurrentThe configured active reference line from which the sync module should deriving its timing. This object is relevant if the 'salixSysSyncTimingMode' is set to '…
1.3.6.1.4.1.2158.2.3.1.5.7ScalarsalixSysSyncAutoRefSwitchread-writecurrentIndication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - Auto reference switching is dis…
1.3.6.1.4.1.2158.2.3.1.5.8ScalarsalixSysSyncFreeRunAlarmread-writecurrentIndication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disabled
1.3.6.1.4.1.2158.2.3.1.5.9ScalarsalixSysSyncWorkingread-writecurrentThe entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to this object, a value not equal …
1.3.6.1.4.1.2158.2.3.1.5.10ScalarsalixSysSyncProtectread-onlycurrentThe entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 indicates that there is no redun…
1.3.6.1.4.1.2158.2.3.1.5.11ScalarsalixSysSyncPrimaryRefStateread-onlycurrentThis variable indicates the state of the primary reference line termination point to be used as a timing source by the sync module. This object is relevant if …
1.3.6.1.4.1.2158.2.3.1.5.12ScalarsalixSysSyncSecondaryRefStateread-onlycurrentThis variable indicates the state of the secondary reference line termination point to be used as a timing source by the sync module. This object is relevant i…
1.3.6.1.4.1.2158.2.3.1.5.13ScalarsalixSysSyncCurrentActiveRefread-onlycurrentIndication of the active reference line from which the sync module is deriving its timing. This object is relevant if the salixSysSyncTimingMode is set to 'lin…
1.3.6.1.4.1.2158.2.3.1.5.14ScalarsalixSysSyncForcedStateread-onlycurrentThis variable indicates the state of the sync module with regard to switching between the configured active reference, the value of the 'salixSysSyncConfigured…
1.3.6.1.4.1.2158.2.3.1.6NodesalixSystemHsf
1.3.6.1.4.1.2158.2.3.1.6.1ScalarsalixSysHsfWorkingread-writecurrentThe PhysicalIndex of the Hybrid Switch Fabric (HSF) module plug-in unit that is performing switching in the SALIX. Writing a new value to this variable will: -…
1.3.6.1.4.1.2158.2.3.1.6.2ScalarsalixSysHsfProtectread-onlycurrentThe entPhysicalIndex of the Hybrid Switch Fabric (HSF) module plug-in unit that is protecting or on standby to the working HSF module, salixHSFWorking. A value…
1.3.6.1.4.1.2158.2.3.1.7NodesalixSystemRsc
1.3.6.1.4.1.2158.2.3.1.7.1ScalarsalixSysRscWorkingread-writecurrentThe PhysicalIndex of the Redundant Shelf Controller (RSC) module plug-in unit that is performing shelf controller operations in the product (ie. talking with m…
1.3.6.1.4.1.2158.2.3.1.7.2ScalarsalixSysRscProtectread-onlycurrentThe entPhysicalIndex of the Redundant Shelf Controller (RSC) module plug-in unit that is protecting or on standby to the working RSC module, salixRscWorking. A…
1.3.6.1.4.1.2158.2.3.1.8ScalarsalixSysLoginMessageread-writecurrentThe message is displayed every time a user logs into the CLI. It may be used to display legal warnings.
1.3.6.1.4.1.2158.2.3.2NodesalixSystemMIBTraps
1.3.6.1.4.1.2158.2.3.2.0NodesalixSystemMIBTrapPrefix
1.3.6.1.4.1.2158.2.3.2.0.1NotificationsalixSysSyncRefLineAlarmcurrentIndicates that the Sync plug-in unit associated with the specified physical entity detected an error condition with the interface configured as a reference. Th…
1.3.6.1.4.1.2158.2.3.2.0.2NotificationsalixSysSyncInvalidRefLineAlarmcurrentIndicates that the Sync plug-in unit associated with the specified physical entity does not have a valid primary or secondary reference line for deriving timin…
1.3.6.1.4.1.2158.2.3.2.0.3NotificationsalixSysSyncClockModeAlarmcurrentIndicates that the clock mode of the working or protect Sync plug-in unit associated with the specified physical entity, 'atmfM4PlugInUnitAvailStatus', changed…
1.3.6.1.4.1.2158.2.3.2.0.4NotificationsalixSysSyncClockModeStateChangecurrentIndicates that the clock mode of the working or protect Sync plug-in unit associated with the specified physical entity, 'atmfM4PlugInUnitAvailStatus', changed.
1.3.6.1.4.1.2158.2.3.2.0.5NotificationsalixSysFileSystemUnavailablecurrentIndicates the System Filesystem is no longer available. This can indicate the loss of connectivity to the NFS server, or loss of the hard disk in systems with …
1.3.6.1.4.1.2158.2.3.3NodesalixSystemMIBCompliance
1.3.6.1.4.1.2158.2.3.3.1NodesalixSystemGroups
1.3.6.1.4.1.2158.2.3.3.1.1GroupsalixSystemGroupcurrentSalix Error Objects Group
1.3.6.1.4.1.2158.2.3.3.2NodesalixSystemCompliances
1.3.6.1.4.1.2158.2.3.3.2.1CompliancesalixSystemCompliancecurrentThe basic implementation requirements for the SALIX-ERROR-MIB.