SCS-ks-MIB
25 objects
This is the unofficial MIB module for the SCS KS.
Imported Objects
| IF-MIB | ifEntry ifIndex |
| RFC1155-SMI | Counter enterprises Gauge IpAddress |
| RFC1213-MIB | DisplayString |
| SNMPv2-CONF | OBJECT-GROUP |
| SNMPv2-MIB | sysContact sysLocation sysName |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9839 | Nodecarel | |||
| 1.3.6.1.4.1.9839.1 | Nodesystm | |||
| 1.3.6.1.4.1.9839.1.1 | Identityscs-ks | This is the unofficial MIB module for the SCS KS. | ||
| 1.3.6.1.4.1.9839.1.2 | Nodescs | |||
| 1.3.6.1.4.1.9839.1.2.1 | Scalarstatus-evaporator-fan | read-only | current | Evaporator Fan alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.2 | Scalarstatus-condenser-fan | read-only | current | Condenser Fan alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.3 | Scalarstatus-compressor | read-only | current | Compressor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.4 | Scalarstatus-heater-thermal-protection | read-only | current | Heater thermal protection alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.5 | Scalarstatus-exhaust-air-sensor | read-only | current | Exhaust air sensor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.6 | Scalarstatus-supply-air-sensor | read-only | current | Supply air sensor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.7 | Scalarstatus-outside-sensor | read-only | current | Outside temperature sensor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.8 | Scalarstatus-room-temperature-sensor | read-only | current | Temperature room sensor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.9 | Scalarstatus-room-humidity-sensor | read-only | current | Humidity room sensor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.10 | Scalarstatus-min-exhaust-air-temperature | read-only | current | Minimum exhaust air temperature alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.11 | Scalarstatus-max-exhaust-air-temperature | read-only | current | Maximum exhaust air temperature alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.12 | Scalarstatus-min-supply-air-temperature | read-only | current | Minimum supply air temperature alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.13 | Scalarstatus-water-sensor | read-only | current | Water sensor alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.14 | Scalarstatus-filter-monitoring | read-only | current | Filter monitoring alarm 0=OK;1=Error |
| 1.3.6.1.4.1.9839.1.2.15 | Scalarexhaust-air-temperature | read-only | current | Exhaust air temperature 235 = 23.5 degree Celsius |
| 1.3.6.1.4.1.9839.1.2.16 | Scalarsupply-air-temperature | read-only | current | Supply air temperature 235 = 23.5 degree Celsius |
| 1.3.6.1.4.1.9839.1.2.17 | Scalaroutside-air-temperature | read-only | current | Outside air temperature 235 = 23.5 degree Celsius |
| 1.3.6.1.4.1.9839.1.2.18 | Scalarroom-temperature | read-only | current | Room temperature 235 = 23.5 degree Celsius |
| 1.3.6.1.4.1.9839.1.2.19 | Scalarroom-humidity | read-only | current | Room humidity 235 = 23.5 % |
| 1.3.6.1.4.1.9839.1.2.20 | Scalarstatus-operational-status | read-only | current | Operational status 0=Off;1=Running |
| 1.3.6.1.4.1.9839.1.2.21 | Scalarstatus-collective-fault | read-only | current | Collective fault alarm 0=Error;1=Ok |