SNI-SERVER-CONTROL-MIB
413 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1 | Nodeenterprises | |||
| 1.3.6.1.4.1.231 | Nodesni | |||
| 1.3.6.1.4.1.231.2 | NodesniProductMibs | |||
| 1.3.6.1.4.1.231.2.10 | NodesniExtensions | |||
| 1.3.6.1.4.1.231.2.10.2 | NodesniServerMgmt | |||
| 1.3.6.1.4.1.231.2.10.2.1 | NodesniInventory | |||
| 1.3.6.1.4.1.231.2.10.2.2 | NodesniCommon | |||
| 1.3.6.1.4.1.231.2.10.2.2.1 | NodesniBios | |||
| 1.3.6.1.4.1.231.2.10.2.2.2 | NodesniEisa | |||
| 1.3.6.1.4.1.231.2.10.2.2.3 | NodesniHd | |||
| 1.3.6.1.4.1.231.2.10.2.2.4 | NodesniBus | |||
| 1.3.6.1.4.1.231.2.10.2.2.5 | NodesniServerControl | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.1 | NodeagentInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.1.1 | ScalaragentId | read-only | mandatory | Agent identification string |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.2 | ScalaragentCompany | read-only | mandatory | Agent's company name |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.3 | ScalaragentVersionString | read-only | mandatory | Agent's version string <Major>.<Minor> (i.e. 1.05) |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.4 | ScalaragentBuild | read-only | mandatory | Compilation time and date of agent program |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.5 | ScalaragentVersionMajor | read-only | mandatory | Agent's major version (numerical) |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.6 | ScalaragentVersionMinor | read-only | mandatory | Agent's minor version (numerical) |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.7 | ScalaragentWriteAllowed | read-only | mandatory | Defines whether writable objects can be written (except shutdown/power-off operations) |
| 1.3.6.1.4.1.231.2.10.2.2.5.1.8 | ScalaragentShutdownAllowed | read-only | mandatory | Defines whether shutdown/power-off objects can be written |
| 1.3.6.1.4.1.231.2.10.2.2.5.2 | Nodeenvironment | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1 | TabletemperatureSensorsTable | not-accessible | mandatory | Table with data of all configured temperature sensors |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1 | RowtemperatureSensors | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.1 | ColumntempCabinetId | read-only | mandatory | ID of the cabinet the temperature sensor is in (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.2 | ColumntempSensorNumber | read-only | mandatory | Number of the sensor in this cabinet (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3 | ColumntempSensorStatus | read-only | mandatory | Status of this temperature sensor (OK, critical or shutdown temperature reached...). The cold and the damage temperature status levels are no longer supported … |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.4 | ColumntempSensorPurpose | read-only | mandatory | Purpose of this temperature sensor (CPU, ambient, housing...). Purposes disable(2) and not-available(6) are no longer used. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.5 | ColumntempLowerWarningLevel | read-only | obsolete | Object made obsolete - no longer supported |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.6 | ColumntempUpperWarningLevel | read-only | mandatory | System sends a temperature warning when temperature rises ABOVE this level (degrees Celsius) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.7 | ColumntempLowerCriticalLevel | read-only | obsolete | Object made obsolete - no longer supported |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.8 | ColumntempUpperCriticalLevel | read-only | mandatory | System becomes critical when temperature rises ABOVE this level (degrees Celsius). A system shutdown is performed if object tempCriticalReaction is set to shut… |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.9 | ColumntempLowerDamageLevel | read-only | obsolete | Object made obsolete - no longer supported |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.10 | ColumntempUpperDamageLevel | read-only | obsolete | Object made obsolete - no longer supported |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.11 | ColumntempCurrentValue | read-only | mandatory | Current temperature value (degrees Celsius; -1: unknown temperature, problem with sensor, see tempSensorStatus) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.12 | ColumntempCriticalReaction | read-write | mandatory | Reaction when a temperature gets critical (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.13 | ColumntempSensorDesignation | read-only | optional | String describing the purpose of each temperature sensor in a housing (e.g. CPU, ambient,...). This object will substitute the tempSensorPurpose object. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2 | TablefansTable | not-accessible | mandatory | Table with data of all configured cooling devices (fans) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1 | Rowfans | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.1 | ColumnfanCabinetId | read-only | mandatory | ID of the cabinet the cooling device (fan) is in (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.2 | ColumnfanNumber | read-only | mandatory | Number of the fan in this cabinet (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.3 | ColumnfanStatus | read-only | mandatory | Status of this fan (OK, failed...). Status disabled(2) is no longer used. Status prefailure-predicted(5) means the fan will fail in near future. Status redunda… |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.4 | ColumnfanPurpose | read-only | mandatory | Purpose of this fan (housing, component, CPU on-chip, power supply...). Purpose disabled(2) is currently not used. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.5 | ColumnfanPositionX | read-only | obsolete | Fax X position - obsolete; for fan indentifying use fanIdentification object |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.6 | ColumnfanPositionY | read-only | obsolete | Fax Y position - obsolete; for fan indentifying use fanIdentification object |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.7 | ColumnfanPositionZ | read-only | obsolete | Fax Z position - obsolete; for fan indentifying use fanIdentification object |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.8 | ColumnfanCurrentSpeed | read-only | mandatory | Current speed of the fan (in revolutions per minute, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.9 | ColumnfanNominalMaximumSpeed | read-only | mandatory | Nominal speed of the fan (in revolutions per minute) on maximum power; the speed is measured the first time the agent is installed and than compared daily to t… |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.10 | ColumnfanCurrentMaximumSpeed | read-only | mandatory | Current speed of the fan (in revolutions per minute) on maximum power (-1 = unknown). |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.11 | ColumnfanMaximumSpeedCriticalLevel | read-only | obsolete | Obsolete - no longer supported. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.12 | ColumnfanMinimumSpeed | read-only | obsolete | Obsolete - no longer supported. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.14 | ColumnfanFailReaction | read-write | mandatory | Reaction when a fan has failed (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.15 | ColumnfanFailShutdownDelay | read-write | mandatory | Delay time (in seconds) when shutdown should commit on fan fail (if shutdown-and-off is configured, 0 = immediately, -1 = unknown). The value unknown(-1) canno… |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.16 | ColumnfanDesignation | read-write | optional | String describing the purpose of each fan in a housing (e.g. CPU, Power Supply,...). This object will substitute the fanPurpose object. |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17 | ColumnfanIdentification | read-write | optional | String identifying each fan in a housing (e.g. CPU0, CPU1, PS0...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.3 | ScalarfanDailyTestTime | read-write | mandatory | Daily time when to automatically test fan speeds (in minutes since midnight; -1 = unknown, automatic fan test not supported). The value unknown(-1) cannot be s… |
| 1.3.6.1.4.1.231.2.10.2.2.5.2.4 | ScalarfanStartTest | read-write | mandatory | Start test of all fans to get the speed at maximum power (this test is normally started automatically once a day). Reading this object just returns the value 0. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3 | NodeerrorHandling | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.3.1 | TableeventLogTable | not-accessible | mandatory | Table with event log entries (can also contain critical errors when an ErrorLog for critical errors is not available) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1 | RoweventLog | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.1 | ColumneventLogEntryNumber | read-only | mandatory | Entry number in eventLogTable (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.2 | ColumneventLogMessageData | read-only | mandatory | Non-critical message log entry as described above |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.2 | ScalareventLogMaxEntries | read-only | mandatory | Number of EventLog entries (can be used to directly get all table entries with one varbind list) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.3 | TableerrorLogTable | not-accessible | optional | Table with major and critial error log entries (can be missing on some hardware platforms) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1 | RowerrorLog | not-accessible | optional | |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.1 | ColumnerrorLogEntryNumber | read-only | mandatory | Entry number in critical errorLogTable (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.2 | ColumnerrorLogMessageData | read-only | mandatory | Major/critical message log entry as described above |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.4 | ScalarerrorLogMaxEntries | read-only | mandatory | Number of ErrorLog entries (can be used to directly get all table entries with one varbind list) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.5 | ScalarhardwareWatchdogStatus | read-only | mandatory | Status of the hardware watchdog (periodically restarted by the server management BIOS). The hardware watchdog is only supported on SMI based management hardwar… |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.6 | ScalarhardwareWatchdogTime | read-only | obsolete | Timeout time of the hardware watchdog (in seconds, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.7 | ScalarhardwareWatchdogEnable | read-write | mandatory | Enable/disable the hardware watchdog. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.8 | ScalarsoftwareWatchdogStatus | read-only | mandatory | Status of the software watchdog (periodically restarted by the server management agent) |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.9 | ScalarsoftwareWatchdogTime | read-write | mandatory | Timeout time of the software watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.10 | ScalarsoftwareWatchdogEnable | read-write | mandatory | Enable/disable the software watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.11 | ScalarsoftwareWatchdogAction | read-write | mandatory | Behavior when the software watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchd… |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.12 | ScalarbootWatchdogStatus | read-only | mandatory | Status of the boot watchdog (started at system boot, reset by the server management agent). If the SC agent is not started within the specified time, the manag… |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.13 | ScalarbootWatchdogTime | read-write | mandatory | Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.14 | ScalarbootWatchdogEnable | read-write | mandatory | Enable/disable the boot watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.3.15 | ScalarbootWatchdogAction | read-write | mandatory | Behavior when the boot watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchdog h… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4 | NodesystemBoard | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1 | TablecpuTable | not-accessible | mandatory | Table with CPU information |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1 | Rowcpu | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.1 | ColumncpuTableIndex | read-only | mandatory | Number of the CPU in the CpuTable (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.2 | ColumncpuType | read-only | mandatory | Type of the CPU (486, Pentium, R2000...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.3 | ColumncpuFrequency | read-only | mandatory | Frequency of the CPU (in MHz, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.4 | ColumncpuStep | read-only | mandatory | Step (version) of the CPU (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6 | ColumncpuStatus | read-only | mandatory | Status of a CPU: unknown(1) : CPU status could not be evaluated disabled(2) : CPU was manually disabled in BIOS setup ok(3) : CPU is available and operating pr… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.7 | ColumncpuModel | read-only | mandatory | Model of the CPU (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.8 | ColumncpuName | read-only | mandatory | Name of the CPU (e.g. 'Pentium', 'Pentium Pro' ...) as text string |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.9 | ColumncpuSocketDesignation | read-only | mandatory | String containing the socket designation of a CPU. This is the same text that is written on the system board. |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.10 | ColumncpuManufacturer | read-only | mandatory | String containing the CPU manufacturer. |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.11 | ColumncpuNrLogicalsPerPhysical | read-only | mandatory | Number of logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threadin… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.12 | ColumncpuCacheL1Size | read-only | mandatory | Level 1 cache size (kByte) of a physical CPU (0 if unknown or not available). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.13 | ColumncpuCacheL2Size | read-only | mandatory | Level 2 cache size (kByte) of a physical CPU (0 if unknown or not available). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.14 | ColumncpuCacheL3Size | read-only | mandatory | Level 3 cache size (kByte) of a physical CPU (0 if unknown or not available). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.15 | ColumncpuNrCoresPerPhysical | read-only | mandatory | Number of cores within one physical CPU (for multi-core CPUs). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.2 | ScalarsecondLevelCacheSize | read-only | mandatory | Size of the second level cache (in kBytes, 0 if not available or disabled, -1 = unknown). Object will be made obsolete in next releases; use cpuCacheL2Size ins… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.3 | ScalarsecondLevelCacheWritePolicy | read-only | mandatory | Write policy of the second level cache (write-back, write-through). Object will be made obsolete in next releases (no longer required). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.4 | ScalarphysicalMemorySize | read-only | mandatory | Size of the whole physical memory on the system board (in MBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.5 | ScalarbaseMemorySize | read-only | mandatory | Size of the base memory (below 1 MB) on the system board (in kBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.6 | ScalarextendedMemorySize | read-only | mandatory | Size of the extended memory (above 1 MB) on the system board (in MBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.7 | ScalarutilizationMethod | read-write | optional | Method to get utilization values: take-snapshot-now: get all values and store them to have all values at one certain time (set this object each time you want t… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.8 | ScalarutilizationPciLoad | read-only | optional | Load on the PCI bus (in percent; -1 if unknown); do no longer use this object for new implementations; object replaced by pciUtilizationTable. |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.9 | ScalarutilizationEisaLoad | read-only | optional | Load on the EISA bus (in percent; -1 if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10 | TablememoryModulesTable | not-accessible | mandatory | Table with memory module descripitions |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1 | RowmemoryModules | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.1 | ColumnmemModuleNumber | read-only | mandatory | Module number (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.2 | ColumnmemModuleBank | read-only | mandatory | Bank number the module belongs to (-1 = unknown). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.3 | ColumnmemModuleStatus | read-only | mandatory | Status of the memory module socket (OK, fail, disabled...). unknown(1) : module status could not be evaluated error(2) : module has encountered errors but is s… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.4 | ColumnmemModuleErrors | read-only | mandatory | Number of (parity) errors in this module since last error count reset (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.5 | ColumnmemModuleStartAddress | read-only | mandatory | Start address of the bank this memory belongs to (-1 = unknown). This object is obsolete when the main memory size exceeds 2 GByte. Use new object memModuleSta… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.6 | ColumnmemModuleSize | read-only | mandatory | Size of this memory module (in bytes, -1 = unknown). This object is obsolete when the module's size exceeds 2 GByte. Use new object memModuleSizeMB instead. |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.7 | ColumnmemModuleType | read-only | mandatory | Type of memory module (Parity, NoParity, ECD, EDO...). Will be made obsolete in next agent releases!!! Use memModuleType2 for newer implementations! |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.8 | ColumnmemModuleType2 | read-only | mandatory | Information about the type of a memory module (Parity, ECC, EDO, SIMM, DIMM...). The type is a combination of one or more bits. Bit field: Bit 0 - Other Bit 1 … |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.9 | ColumnmemModuleSocketDesignation | read-only | mandatory | String containing the socket designation of a memory module. This is the same text that is written on the system board. |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.10 | ColumnmemModuleCorrectableErrors | read-only | mandatory | Number of correctable errors in this module since last error count reset (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.11 | ColumnmemModuleApproved | read-only | mandatory | Information whether the memory module has been approved by the system vendor. unknown(1) is given when a module is not available or module cannot be accessed; … |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.12 | ColumnmemModuleStartAddressMB | read-only | mandatory | Start address (in MBytes) of the bank this memory belongs to (-1 = unknown). This object makes the object memModuleStartAddress obsolete (4 GByte limit). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.13 | ColumnmemModuleSizeMB | read-only | mandatory | Size (in MBytes) of this memory module (-1 = unknown). This object makes the object memModuleSize obsolete (4 GByte limit). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.11 | ScalarmemoryErrorCounterReset | read-write | mandatory | Reset the memory module error counters (and set a new start time), reading this object just returns the value 0. |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.12 | ScalarmemoryErrorCounterStartTime | read-only | mandatory | Time when memory module error counters were started (seconds since 1/1/1970, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.13 | TablepciUtilizationTable | not-accessible | mandatory | Table with PCI bus utilization data; independent of utilizationMethod object, update method for this table is always get-current-values. The number of entries … |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1 | RowpciUtilization | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.1 | ColumnpciUtilBusNumber | read-only | mandatory | PCI bus number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.2 | ColumnpciUtilBusLoad | read-only | mandatory | PCI bus load (in percent, 0xffffffff if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.3 | ColumnpciUtilBusTransferRate | read-only | mandatory | PCI bus data transfer rate (in MBytes/second, 0xffffffff if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.4 | ColumnpciUtilBusEfficiency | read-only | mandatory | PCI bus efficiency, ratio of data transfer rate through bus load (in percent); avarage value over all devices on this PCI bus; optimum value is 100 percent (0x… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.14 | ScalarsniScBiosVersionString | read-only | mandatory | String containing complete BIOS version, e.g. V4.05 R1.03.887 |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.15 | ScalarsniScNumberCpuSockets | read-only | mandatory | Number of CPU sockets available on the system board. This is not the number of currently installed CPUs! This object also describes the number of entries in th… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.16 | ScalarsniScNumberMemoryModules | read-only | mandatory | Number of memory module sockets available on the system board (or memory extension board). This is not the number of currently installed memory modules! This o… |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.17 | ScalarsniScNumberPciBusses | read-only | mandatory | Number of PCI busses available in the system (-1 = unknown). |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.18 | ScalartotalMemoryUsage | read-only | mandatory | Total system memory usage (virtual and physical, in KBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.19 | ScalartotalMemoryUsagePercent | read-only | mandatory | Total system memory usage (virtual and physical, in percent, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.20 | ScalarphysicalMemoryUsage | read-only | mandatory | Physical system memory usage (in KBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.21 | ScalarphysicalMemoryUsagePercent | read-only | mandatory | Physical system memory usage (in percent, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.22 | ScalartotalMemoryAvailable | read-only | mandatory | Total system memory available (virtual and physical, in KBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.23 | ScalarphysicalMemoryAvailable | read-only | mandatory | Physical system memory available (in KBytes, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.4.24 | ScalarphysicalMemoryOsSize | read-only | mandatory | Total size of the whole physical memory available to the operating system; this value is similar to 'physicalMemorySize', but may be less if the system has mir… |
| 1.3.6.1.4.1.231.2.10.2.2.5.5 | NodepagerSetup | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1 | TablepagerUserTable | not-accessible | mandatory | Table with info of the users that should be paged |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1 | RowpagerUser | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.1 | ColumnpagerUserIndex | read-only | mandatory | Index into pager user table (0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.2 | ColumnpagerType | read-write | mandatory | Type of the installed pager (signal, numeric, alfa-numeric). The value unknown(1) and not-available(2) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.3 | ColumnpagerUserName | read-write | mandatory | Name of the pager user |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.4 | ColumnpagerUserDescription | read-write | mandatory | Description (function, optional) of the pager user |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.5 | ColumnpagerActive | read-write | mandatory | Describes whether this pager is active and should be called. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.6 | ColumnpagerNumber | read-write | mandatory | User ID number of the user's pager |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.7 | ColumnpagerServiceProviderNumber | read-write | mandatory | Telephone dial number of the pager service provider (can also contain additional modem dial characters) |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.8 | ColumnpagerActivityPrompt | read-write | mandatory | Prompt string that should be received before pager number can be sent |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.9 | ColumnpagerTimeModel | read-write | mandatory | Encoded string containing a pager time model (when should which user be paged); this value is currently not used. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.2 | ScalarpagerInitString | read-only | mandatory | Init string that will be sent to the pager modem before the dialing begins |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.3 | ScalarpagerServerNumber | read-write | mandatory | Number of this server. It is sent together with the error number as a message to the user's pager (-1 = unknown). The value unknown(-1) cannot be set, a SET wi… |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.4 | ScalarpagerComPort | read-write | mandatory | COM port number (1...4) the pager modem is connected to. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.5 | ScalarpagerComPortBaudRate | read-write | mandatory | Baud rate of the pager COM port. Following values are supported: 1200, 2400, 4800, 9600, 19200 (-1 = unknown). The value unknown(-1) cannot be set, a SET will … |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.6 | ScalarpagerComPortParity | read-write | mandatory | Parity check configuration for the pager COM port. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.7 | ScalarpagerComPortNumBits | read-write | mandatory | Number of bits per byte on the pager COM port (7, 8, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.8 | ScalarpagerComPortFlowControl | read-write | mandatory | Flow control method of the pager COM port (Hardware, XON/XOFF...). The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.5.9 | ScalarpagerModemName | read-write | mandatory | Optional modem name or type; can be used just as info to be displayed. |
| 1.3.6.1.4.1.231.2.10.2.2.5.7 | NodestandardBiosSetup | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.7.1 | ScalarstdSetupPasswordEnable | read-only | mandatory | Tells whether a password is configured for the standard BIOS (read-only) |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.2 | ScalarstdSetupBootSource | read-write | mandatory | Source medium to boot from: Normal system or diagnostic system standard(2): standard boot diag-system(4): boot from alternate diagnostic system The source the … |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.3 | ScalarstdSetupPostErrorHalt | read-write | mandatory | Describes what to do when a POST error has occured (halt on any error, no halt on any error...). The values unknown(1) and other(9) cannot be set, a SET will d… |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.4 | ScalarstdSetupSerialInterface1 | read-write | mandatory | The COM port which the on-board serial interface 1 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.5 | ScalarstdSetupSerialInterface2 | read-write | mandatory | The COM port which the on-board serial interface 2 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.6 | ScalarstdSetupParallelInterface | read-write | mandatory | The LPT port which the on-board parallel interface is mapped to (1...3). The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.7 | ScalarstdSetupFloppyController | read-write | mandatory | Describes whether the floppy controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.8 | ScalarstdSetupHarddiskController | read-write | mandatory | Describes whether the IDE harddisk controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.9 | ScalarstdSetupMouseController | read-write | mandatory | Describes whether the mouse port controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.8 | NodeserverBiosSetup | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.8.1 | ScalarsrvSetupCabinetId | read-write | mandatory | Cabinet ID number of this server (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. Use this number as cabinetId for all table… |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.2 | ScalarsrvSetupServerRackSlot | read-write | optional | Slot number (in a rack) this server is in (only for rack servers; -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. This objec… |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.3 | ScalarsrvSetupServerGroupStart | read-write | obsolete | deleted |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.4 | ScalarsrvSetupServerGroupEnd | read-write | obsolete | deleted |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.5 | ScalarsrvSetupServerGroupMembers | read-write | obsolete | deleted |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.6 | ScalarsrvSetupSeGroupStart | read-write | obsolete | deleted |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.7 | ScalarsrvSetupSeGroupEnd | read-write | obsolete | deleted |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.8 | ScalarsrvSetupSeGroupMembers | read-write | obsolete | deleted |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.9 | ScalarsrvSetupRemoteOnEnable | read-write | mandatory | Describes whether remote-on via RI modem line is enabled or not available. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.10 | ScalarsrvSetupMaxRestartRetries | read-write | mandatory | Maximum number of retries to reboot/restart the server when a shutdown (and power-off) had occured. After this number of retries the action defined in 'srvSetu… |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.11 | ScalarsrvSetupRebootFailAction | read-write | mandatory | Describes the action on a specified number of failed reboot retries (srvSetupMaxRestartRetries=0): unknown(1) - diagnostic system cannot be determined (cannot … |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.12 | ScalarsrvSetupRebootFailPager | read-write | mandatory | Describes whether the pager should be activated when reboot after error shutdown had occured. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.13 | ScalarsrvSetupSeGroupNumber | read-write | mandatory | Group number for storage extension communication bus. Legal values are 0..9, -1 = unknown. The value unknown(-1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.14 | ScalarsrvSetupRestartRetriesDefault | read-write | mandatory | Default number of retries to reboot/restart the server when a shutdown (and power-off) had occured. This value will be copied to object srvSetupMaxRestartRetri… |
| 1.3.6.1.4.1.231.2.10.2.2.5.9 | NodepowerOnOff | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.9.1 | TableonOffTimesTable | not-accessible | mandatory | Table with system power on/off times; power-on will be performed by the real-time clock, power-off (with shutdown) by the operating system (system control serv… |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1 | RowonOffTimes | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.1 | ColumnonOffWeekday | read-only | mandatory | Day of the week the times should act upon (index, 1 based); 1 = Sunday, 2 = Monday... |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.2 | ColumnonTime | read-write | mandatory | Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed. |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.3 | ColumnoffTime | read-write | mandatory | Time the system should be switched off (by the operating system; in minutes since midnight; -1 = disabled, no off time). Only values -1 and 0..1439 are allowed. |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.2 | ScalarshutdownDelayTime | read-write | mandatory | The delay time (in minutes) the agent should wait before executing a shutdown (with doShutdown); 0 = default = shutdown immediately; -1 = unknown. The value un… |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.3 | ScalardoShutdown | read-write | mandatory | Execute a shutdown; argument tells what kind of shutdown: shutdown: wait for user to switch off or reboot shutdown-and-off: switch off after shutdown shutdown-… |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.4 | ScalarpowerOnCounts | read-only | mandatory | Tells how often the server was switched on in its life (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.5 | ScalarpowerOnDurationHours | read-only | mandatory | Tells how long the system was switched on in its life (in hours; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.6 | ScalarpowerOffDurationHours | read-only | mandatory | Tells how long the system was switched off in its life (in hours; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.7 | ScalarerrorOffRestartDelay | read-write | mandatory | Delay (in minutes) when the system should be automatically switched on again (by real-time clock) after an error power-off (-1 = no switch-on function). The va… |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.8 | ScalarlastPostStatus | read-only | obsolete | Describes whether the last (current) POST (power on self test) was errornous. Object is now obsolete - use object systemBootStatus instead! |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.9 | ScalarlastPowerOffSource | read-only | mandatory | Reason why the system was switched off last time |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.10 | ScalarlastPowerOnSource | read-only | mandatory | Source the system was switched on from |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.11 | ScalarpowerOnTime | read-only | mandatory | Time and Date the system was booted (seconds since 1/1/1970; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.12 | ScalardoPowerOnOff | read-write | mandatory | Switch the server on or off; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on ag… |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.13 | ScalarsystemBootResult | read-only | mandatory | Result of the last server boot. |
| 1.3.6.1.4.1.231.2.10.2.2.5.9.14 | ScalarsystemBootStatus | read-only | mandatory | Status of the current boot process. |
| 1.3.6.1.4.1.231.2.10.2.2.5.10 | NodesystemControlInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.10.1 | ScalarnumberCabinetsConfigured | read-only | mandatory | Number of configured cabinets (server and storage extensions, at least 1: the server itself) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.2 | ScalarnumberCabinetsDetected | read-only | mandatory | Number of detected cabinets (server and storage extensions, at least 1: the server itself). This is also the number of entries in cabinetInfosTable. |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3 | TablecabinetInfosTable | not-accessible | mandatory | Table with data of all configured cabinets |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1 | RowcabinetInfos | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.1 | ColumncabinetId | read-only | mandatory | Cabinet ID number, index into the cabinet table |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.2 | ColumncabinetLocation | read-write | mandatory | The place where the cabinet is located (user can store any string here to identify the cabinet location) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.3 | ColumncabinetIdentNumber | read-write | mandatory | System ident number (serial number) - will be a number like 'XYZZ 12345678'. XYZZ is the cabinet identifier and is mandatory. It will be used to identify the c… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.4 | ColumncabinetSystemName | read-only | mandatory | System name string (i.e. PCD-5S, Primergy 150...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.5 | ColumncabinetNumberFans | read-only | mandatory | The number of configured cooling devices (fans) in this cabinet (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.6 | ColumncabinetNumberTempSensors | read-only | mandatory | The number of configured temperature sensors in this cabinet (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.7 | ColumncabinetNumberPowerSupplies | read-only | mandatory | The number of available power supplies in this cabinet (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.8 | ColumncabinetPowerSupplySlots | read-only | mandatory | The number of power supply slots in this cabinet (is the maximum number of installable power supplies; 0 if no hot-plug slots available; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.9 | ColumncabinetUpsUsed | read-only | mandatory | Uninterruptable power supply for this cabinet available: 0: No UPS 1..n: Index in UPS table -1: unknown |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.10 | ColumncabinetBoardSerialNumber | read-only | mandatory | Serial number of the cabinet's system board |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.11 | ColumncabinetBoardRevision | read-only | obsolete | Revision (GS) of the cabinet's system board (-1 = unknown). Value obsolete, use sieScCabinetBoardRevisionString instead! |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.12 | ColumncabinetBoardId | read-only | mandatory | Identifier string of the cabinet's system board |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.13 | ColumncabinetManagementControllerType | read-only | mandatory | Type of the cabinet's system management controller (i.e. SNI System Control Board) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.14 | ColumncabinetControllerFirmwareMajor | read-only | mandatory | Firmware version (major number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.15 | ColumncabinetControllerFirmwareMinor | read-only | mandatory | Firmware version (minor number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.16 | ColumncabinetAttribute | read-only | mandatory | Attribute of a cabinet (Primary/secondary server, storage extension...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.17 | ColumncabinetPowerOnStatus | read-only | mandatory | Power-on state of the cabinet |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.18 | ColumncabinetStatusSummary | read-only | mandatory | Describes the status of a cabinet (OK, degraded, error...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.19 | ColumncabinetLastPoweroffSource | read-only | mandatory | The source from which the cabinet was powered off last time |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.20 | ColumncabinetActionAfterAcFail | read-write | mandatory | Action on AC power resume after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same pow… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.21 | ColumncabinetBbuUsed | read-only | mandatory | Battery buffering unit for this cabinet available. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.22 | ColumncabinetSystemType | read-only | obsolete | Value is obsolete. This value should no longer be used for cabinet identification. Use cabinetHousingType to identify the housing type and cabinetSystemName fo… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23 | ColumncabinetStatusDetail | read-only | mandatory | More detailed status information from this cabinet. The StatusDetail object is set to reflect the new status. ok: (status ok) no failures detected. selftestWar… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.24 | ColumncabinetHousingType | read-only | mandatory | Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object ca… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.25 | ColumncabinetFrontDoorStatus | read-only | mandatory | Status of the cabinet's front door |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.26 | ColumncabinetHousingOpenStatus | read-only | mandatory | Status describing whether the housing is open or closed |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.27 | ColumnsieScCabinetNumberVoltages | read-only | mandatory | Number of entries in power supply voltage table |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.28 | ColumnsieScCabinetControllerFirmware | read-only | mandatory | The cabinet's system management controller firmware version (i.e. '1.1.4.88'). This object will replace the previous objects cabinetControllerFirmwareMinor and… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.29 | ColumnsieScCabinetBoardRevisionString | read-only | mandatory | Revision string (GS, WGS...) of the cabinet's system board. This object replaces the previous object cabinetBoardRevision. |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.30 | ColumnsieScCabinetAdministrativeURL | read-only | mandatory | Provides a URL that may be used by a front-end to start a web browser and connect it directly to the cabinet's administrative web server (e.g. https://10.0.0.2… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.31 | ColumnsieScRemcsId | read-only | mandatory | REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID fo… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.4 | ScalarstatusSummary | read-only | obsolete | Value is obsolete |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.5 | ScalarserverType | read-only | obsolete | Value is obsolete. This value should no longer be used for server identification. Use serverHousingType to identify the housing type and cabinetSystemName for … |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.6 | ScalarserverHousingType | read-only | mandatory | Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object se… |
| 1.3.6.1.4.1.231.2.10.2.2.5.10.7 | ScalarserverUUID | read-only | mandatory | Universal Unique ID (UUID) number - this is a world wide unique ID number of the server. Can be used for identifying a server. This UUID is formatted as specif… |
| 1.3.6.1.4.1.231.2.10.2.2.5.11 | NodepowerSupply | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.11.1 | TablepowerSuppliesTable | not-accessible | mandatory | Table with power supply groups in the cabinets |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1 | RowpowerSupplies | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.1 | ColumnpowerSupplyCabinetId | read-only | mandatory | Cabinet ID, index into the power supply table (0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.2 | ColumnpowerSupplyStatus | read-only | mandatory | Status of the cabinet's power supply group; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < … |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.3 | ColumnpowerSupplyRedundancy | read-only | mandatory | Number of available redundant power supply units (i.e. 2 units minimum, 3 available -> redundancy is 1, -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.2 | TablepowerSupplyUnitsTable | not-accessible | mandatory | Table with info about the configured power supply units |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1 | RowpowerSupplyUnits | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.1 | ColumnpowerSupplyUnitCabinetId | read-only | mandatory | Cabinet ID, index into the power supply unit table (0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.2 | ColumnpowerSupplyUnitNumber | read-only | mandatory | Power supply unit number, index into power supply unit table (0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.3 | ColumnpowerSupplyUnitStatus | read-only | mandatory | Status of the power supply unit (OK, failed, not present...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.4 | ColumnpowerSupplyUnitDesignation | read-only | mandatory | Power supply unit designation. This string specifies a name/designation for the power supply unit. The designation string may not be available on some platform… |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4 | TablesniScVoltageTable | not-accessible | mandatory | Table with power supply voltage information |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1 | RowsniScVoltages | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.1 | ColumnsniScVoltageCabinetNumber | read-only | mandatory | Cabinet number, index into the power supply voltage table (0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2 | ColumnsniScVoltageNumber | read-only | mandatory | Power supply voltage number, index into power supply voltage table (0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.3 | ColumnsniScVoltageStatus | read-only | mandatory | Status of the power supply voltage; 'not-available' maybe the voltage of an empty CPU socket; 'out-of-range' comes when the voltage is out of range; 'prefailur… |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.4 | ColumnsniScVoltageDesignation | read-only | mandatory | Power supply voltage designation. This string specifies the voltage by clear text (e.g. 5V, 12V, 3.3V...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.5 | ColumnsniScVoltageMinimumValue | read-only | mandatory | Power supply voltage minimum level (1/100th Volts; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.6 | ColumnsniScVoltageMaximumValue | read-only | mandatory | Power supply voltage maximum level (1/100th Volts; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.7 | ColumnsniScVoltageCurrentValue | read-only | mandatory | Power supply voltage current level, negative voltages are reported as negative values (1/100th Volts, e.g. 330 means 3.30 Volts; -177 (0xFFFFFF4F) means -1.77 … |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.8 | ColumnsniScVoltageNominalValue | read-only | mandatory | Power supply voltage nominal level (1/100th Volts; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.9 | ColumnsniScVoltageOutputLoad | read-only | mandatory | Power supply output load in percent of maximum load; 0xFFFFFFFF = unknown |
| 1.3.6.1.4.1.231.2.10.2.2.5.12 | NodeuninterruptablePowerSupply | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.12.1 | ScalarupsCount | read-only | mandatory | Number of uninterruptable power supplies (UPS) in this system (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2 | TableupsInfosTable | not-accessible | mandatory | Table with uninterruptable power supplies used in this system. The index is the UPS number used in the system. One or more server or storage-extension objects … |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1 | RowupsInfos | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.1 | ColumnupsNumber | read-only | mandatory | Number of the UPS in this table (index, 1 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.2 | ColumnupsDetected | read-only | mandatory | Tells whether the UPS was detected |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.3 | ColumnupsDischargeTime | read-only | mandatory | Maximum time this UPS will be discharged, after that a shutdown will be performed (seconds; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.4 | ColumnupsVendor | read-only | mandatory | Vendor name of the UPS |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.5 | ColumnupsType | read-only | mandatory | Type of the UPS; can be used to identify an OEM UPS with an OEM agent |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.6 | ColumnupsOemAgent | read-only | mandatory | Object identifier of an OEM UPS MIB; no agent if empty OID |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.7 | ColumnupsOemAgentAddress | read-only | mandatory | IP address of an OEM UPS SNMP agent; no agent if empty |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8 | ColumnupsTimeOnBatterySeconds | read-only | mandatory | Time (in seconds) the UPS is running on battery since power fail (will be cleared on power recovery) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.3 | ScalarspbbuStatus | read-only | optional | Status of the service processor's backup battery (not present, OK, recharging) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.4 | ScalarspbbuDischargeTime | read-only | optional | Maximum time this backup battery will be discharged, after that a shutdown will be performed (seconds; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.5 | ScalarspbbuTimeOnBatterySeconds | read-only | optional | Time (in seconds) the backup battery is running on battery since power fail (will be cleared on power recovery) |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.6 | ScalarspbbuDoChargeCycle | read-write | optional | Perform a discharge/charge cycle on the backup battery. Reading this object just returns the value 0. |
| 1.3.6.1.4.1.231.2.10.2.2.5.12.7 | ScalarspbbuChargeStatus | read-only | optional | Reads the current charge level of the rechargeable battery (in percent of the maximum capacity). |
| 1.3.6.1.4.1.231.2.10.2.2.5.13 | Nodediagnostics | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.13.1 | ScalarsendTestTrap | read-write | mandatory | Send a trap to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Reading this object just returns the value 0. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14 | Nodemanagement | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1 | TableinterfaceParametersTable | not-accessible | mandatory | Table with the interface parameters of all management channels, which are controlled by this server. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1 | RowinterfaceParameters | not-accessible | mandatory | The interface parameters of the designated management channel interface. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.1 | ColumninterfaceCabinetId | read-only | mandatory | CabinetId of the cabinet where the management channel interface resides. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.2 | ColumninterfaceNumber | read-only | mandatory | Index number of the channel management interface (index, 0 based). |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.3 | ColumninterfaceType | read-only | mandatory | The interface type of the interface. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.4 | ColumnipAddress | read-only | mandatory | The IP v4 address of the interface. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.5 | ColumnipAdressNetMask | read-only | mandatory | The IP v4 subnet mask of the interface. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.6 | ColumnphysicalAddress | read-only | mandatory | The interface address of the physical layer of the interface (MAC address). |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.7 | ColumnphoneNumber | read-only | mandatory | The telephone dial number of this interface. Only useful if the interfaceType is of type dial-up(3). |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.8 | ColumninterfaceChannelType | read-only | mandatory | The managegement channel type of the interface: primary: local operating system interface secondary: local management controller LAN interface management-blade… |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.9 | ColumndhcpConfigured | read-only | mandatory | Defines if the ip address should be requested by a dhcp service. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.10 | ColumncontrollerType | read-only | mandatory | The type of the remote or baseboard management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined… |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.11 | ColumncontrollerModel | read-only | mandatory | The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used… |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.12 | ColumncontrollerFWVersion | read-only | mandatory | The FW version of the remote or baseboard management controller as string; |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2 | TableserviceComponentsTable | not-accessible | mandatory | Table with the components attached to the service processor |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1 | RowserviceComponents | not-accessible | mandatory | The components attached to the service processor |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.1 | ColumnserviceComponentProcessorId | read-only | mandatory | Id of the service processor this component is attached to (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.2 | ColumnserviceComponentId | read-only | mandatory | Index number of the service component (index, 0 based) |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.3 | ColumnserviceComponentName | read-only | mandatory | The name of the component in human readable form |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.4 | ColumnserviceComponentType | read-only | mandatory | The type of the componen we are dealing with. |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.5 | ColumnserviceComponentStatus | read-only | mandatory | Describes the status of the component managed by the service processor. Degraded means that some problems have occurred. Error that the component has reported … |
| 1.3.6.1.4.1.231.2.10.2.2.5.14.3 | ScalarchannelType | read-only | mandatory | The managegement channel type of the currently used management channel. |
| 1.3.6.1.4.1.231.2.10.2.2.5.20 | NodetrapInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.5.20.1 | ScalartrapServerName | not-accessible | mandatory | Name of server the trap occured |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.2 | ScalartrapTime | not-accessible | mandatory | Time the trap occured (in seconds since 01/01/1970 00:00h) |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.3 | ScalartrapCabinetNumber | not-accessible | mandatory | Number of the cabinet where the trap was generated |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.4 | ScalartrapObjectNumber | not-accessible | mandatory | Number of the object that generated the trap (fan, temperature sensor...) |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.5 | ScalartrapString | not-accessible | mandatory | Additional string to be displayed in the trap text |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.6 | ScalartrapMinutesRemaining | not-accessible | mandatory | The estimated remaining BBU/UPS capacity in minutes. In the current implementation this is the time remaining until the system will shut down. |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.7 | ScalartrapSecondsOnBattery | not-accessible | mandatory | See scbUPSSecondsOnBattery/scbBBUSecondsOnBattery. |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.8 | ScalartrapConfigLowBattTime | not-accessible | mandatory | The value of trapMinutesRemaining at which a shut down is initiated. In the current implementation this is always 0. |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.9 | ScalartrapNumValue | not-accessible | mandatory | Additional numeric value to be displayed in the trap text |
| 1.3.6.1.4.1.231.2.10.2.2.5.20.10 | ScalartrapManagementInterfaceNumber | not-accessible | mandatory | The number of the management channel interface. |
| 1.3.6.1.4.1.231.2.10.2.3 | NodesniPcSpecific | |||
| 1.3.6.1.4.1.231.2.10.2.4 | NodesniScb | |||
| 1.3.6.1.4.1.231.2.10.2.5 | NodesniOsSpecific | |||
| 1.3.6.1.4.1.231.2.10.2.5.1 | NodesniNetware | |||
| 1.3.6.1.4.1.231.2.10.2.5.2 | NodesniWinNt | |||
| 1.3.6.1.4.1.231.2.10.2.5.3 | NodesniOs2 | |||
| 1.3.6.1.4.1.231.2.10.2.5.4 | NodesniUnix | |||
| 1.3.6.1.4.1.231.2.10.2.6 | NodesniOemComponents | |||
| 1.3.6.1.4.1.231.2.10.2.6.1 | NodesniOemDpt | |||
| 1.3.6.1.4.1.231.2.10.2.6.2 | NodesniOemMylex | |||
| 1.3.6.1.4.1.231.2.10.2.6.2.1 | NodesniMlxDiskArray | |||
| 1.3.6.1.4.1.231.2.10.2.7 | NodesniSecurity | |||
| 1.3.6.1.4.1.231.2.10.2.7.1 | NodesniSmSecurity | |||
| 1.3.6.1.4.1.231.2.10.2.8 | NodesniServerView | |||
| 1.3.6.1.4.1.231.2.10.2.600 | NodetestTrap | Test trap to verify trap connection. | ||
| 1.3.6.1.4.1.231.2.10.2.601 | NodefanError | The indicated fan failed. | ||
| 1.3.6.1.4.1.231.2.10.2.602 | NodetempOk | The temperature of the indicated sensor has decreased to the normal level. | ||
| 1.3.6.1.4.1.231.2.10.2.603 | NodetempWarn | The temperature of the indicated sensor has reached the warning level. | ||
| 1.3.6.1.4.1.231.2.10.2.604 | NodetempCritical | The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled. | ||
| 1.3.6.1.4.1.231.2.10.2.606 | NodetrapOnBattery | The UPS is operating on battery power or the power supply is drawing current from the backup battery unit (BBU). This status is persistent and is resent at one… | ||
| 1.3.6.1.4.1.231.2.10.2.607 | NodetrapOnMains | The mains voltage returned after a power failure. | ||
| 1.3.6.1.4.1.231.2.10.2.608 | NodeselftestWarning | Currently the only possible warning is: SCB battery (nearly) empty. | ||
| 1.3.6.1.4.1.231.2.10.2.609 | NodeselftestError | The Server Management controller failed. | ||
| 1.3.6.1.4.1.231.2.10.2.610 | NodesvCommunicationFailure | Communication with the Server Management controller lost. | ||
| 1.3.6.1.4.1.231.2.10.2.611 | NodescbUnconfiguredUPSDetected | A UPS has been detected, but no UPS is configured. This trap will be repeated every 60 minutes until the condition is removed. | ||
| 1.3.6.1.4.1.231.2.10.2.612 | NodescbUPSNotdetected | A UPS is configured, but no UPS has been detected. This trap will be repeated every 60 minutes until the condition is removed. | ||
| 1.3.6.1.4.1.231.2.10.2.613 | NodescbUnconfiguredBBUDetected | A BBU has been detected, but no BBU is configured. This trap will be repeated every 60 minutes until the condition is removed. | ||
| 1.3.6.1.4.1.231.2.10.2.614 | NodescbBBUNotdetected | A BBU is configured, but no BBU has been detected. This trap will be repeated every 60 minutes until the condition is removed. | ||
| 1.3.6.1.4.1.231.2.10.2.615 | NodenotEnoughCabinets | One or more storage extensions missing. | ||
| 1.3.6.1.4.1.231.2.10.2.616 | NodetooManyCabinets | The actual number of storage extensions is higher than the configured number. | ||
| 1.3.6.1.4.1.231.2.10.2.617 | NodecabinetSwitchedOff | The cabinet has been switched off. | ||
| 1.3.6.1.4.1.231.2.10.2.618 | NodecabinetSwitchedOn | The cabinet has been switched on. | ||
| 1.3.6.1.4.1.231.2.10.2.620 | NodeinternalError | The agent has detected an internal error. | ||
| 1.3.6.1.4.1.231.2.10.2.621 | NodeserverShutdown | The server is being shut down. | ||
| 1.3.6.1.4.1.231.2.10.2.622 | NodefanCriticalError | The indicated fan became critical. | ||
| 1.3.6.1.4.1.231.2.10.2.623 | NodecabinetNotConfigured | The agent has detected a mismatch in the configuration of the server. | ||
| 1.3.6.1.4.1.231.2.10.2.624 | NodepowerSupplyRemoved | One hot-replace power supply was removed. | ||
| 1.3.6.1.4.1.231.2.10.2.625 | NodepowerSupplyAdded | One hot-replace power supply was added. | ||
| 1.3.6.1.4.1.231.2.10.2.626 | NodepowerSupplyFailed | One hot-replace power supply failed. | ||
| 1.3.6.1.4.1.231.2.10.2.627 | NodepowerSupplyOk | Power supply is working again. | ||
| 1.3.6.1.4.1.231.2.10.2.628 | NodepowerSupplyStatusCritical | Power supply status has become critical. | ||
| 1.3.6.1.4.1.231.2.10.2.629 | NodefanOk | The indicated fan is OK again. | ||
| 1.3.6.1.4.1.231.2.10.2.630 | NodetempSensorBroken | The indicated temperature sensor is broken. | ||
| 1.3.6.1.4.1.231.2.10.2.631 | NodeserverManagementDisabled | The server management BIOS is disabled. | ||
| 1.3.6.1.4.1.231.2.10.2.632 | NodetrapAcFail | Mains failed in the specified cabinet. This can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this event. | ||
| 1.3.6.1.4.1.231.2.10.2.633 | NodetrapDuplicateCabinetId | Two ore more cabinets (server or storage extension) have the same ID number. The system will not run properly. | ||
| 1.3.6.1.4.1.231.2.10.2.634 | NodetrapEventLog | An error message was written into the systemboard's event/error log. This could have happened when an error occured before the agent was running or any error w… | ||
| 1.3.6.1.4.1.231.2.10.2.635 | NodetempSensorOk | The indicated broken temperature sensor is OK again. | ||
| 1.3.6.1.4.1.231.2.10.2.636 | NodesvCommunicationEstablished | Communication with the Server Management controller established again. | ||
| 1.3.6.1.4.1.231.2.10.2.637 | NodecorrectableMemErrorAddr | A correctable memory error at specified address was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.638 | NodeuncorrectableMemErrorAddr | An uncorrectable memory error at specified address was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.639 | NodecorrectableMemErrorBank | A correctable memory error at specified bank was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.640 | NodeuncorrectableMemErrorBank | An uncorrectable memory error at specified bank was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.641 | NodecorrectableMemErrorModule | A correctable memory error at specified module was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.642 | NodeuncorrectableMemErrorModule | An uncorrectable memory error at specified module was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.643 | NodecorrectableMemError | A correctable memory error at unknown address was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.644 | NodeuncorrectableMemError | An uncorrectable memory error at unknown address was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.645 | NodepowerOffTimeReached | The power-off time is reached! System will shutdown in after delay. | ||
| 1.3.6.1.4.1.231.2.10.2.646 | NodefrontDoorStatusChanged | The front door status has changed. | ||
| 1.3.6.1.4.1.231.2.10.2.647 | NodehousingOpenStatusChanged | The housing open status has changed | ||
| 1.3.6.1.4.1.231.2.10.2.648 | NodesniScRedundantFanFailed | The indicated redundant fan failed. | ||
| 1.3.6.1.4.1.231.2.10.2.649 | NodesniScRedundantPowerSupplyFailed | One redundant hot-replace power supply failed. | ||
| 1.3.6.1.4.1.231.2.10.2.650 | NodesniScVoltageOk | Power supply voltage is within normal range again. | ||
| 1.3.6.1.4.1.231.2.10.2.651 | NodesniScVoltageTooLow | Power supply voltage is too low. | ||
| 1.3.6.1.4.1.231.2.10.2.652 | NodesniScVoltageTooHigh | Power supply voltage is too high. | ||
| 1.3.6.1.4.1.231.2.10.2.653 | NodesniScFanAdded | The indicated hot-plug fan was inserted. | ||
| 1.3.6.1.4.1.231.2.10.2.654 | NodesniScFanRemoved | The indicated hot-plug fan was removed. | ||
| 1.3.6.1.4.1.231.2.10.2.655 | NodesniScShutdownCancelled | This event will be sent if a pending server shutdown has been cancelled by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.656 | NodesniScCpuSpeedChanged | The CPU clock frequency has been reduced because of a temperature problem. | ||
| 1.3.6.1.4.1.231.2.10.2.657 | NodesieScPowerOn | The server has been powered on. | ||
| 1.3.6.1.4.1.231.2.10.2.658 | NodesieScNoBootCpu | The system boot failed because no valid boot CPU has been found. | ||
| 1.3.6.1.4.1.231.2.10.2.659 | NodesieScPostError | This trap will be sent when the system boot fails, because the power on selftest (POST) has reported an error. | ||
| 1.3.6.1.4.1.231.2.10.2.660 | NodesieScSetupEntered | This trap will be sent when the bios setup has been entered. | ||
| 1.3.6.1.4.1.231.2.10.2.661 | NodesieScBootError | This trap will be sent when no bootable operating system can be found. | ||
| 1.3.6.1.4.1.231.2.10.2.662 | NodesieScBootWatchdogExpired | This trap will be sent when the boot watchdog expires. | ||
| 1.3.6.1.4.1.231.2.10.2.663 | NodesieScSoftwareWatchdogExpired | This trap will be sent when the software watchdog expires. | ||
| 1.3.6.1.4.1.231.2.10.2.664 | NodesieScUserAuthenticationFailure | This trap will be sent when an user authentication failure is detected via PPP, FTP, HTTP or telnet fails. | ||
| 1.3.6.1.4.1.231.2.10.2.665 | NodesieScDiagnosticBoot | This trap will be sent when a server is reset and diagnostic boot is enabled. The value in trapString specifies the primary channel i.e. the server name (from … | ||
| 1.3.6.1.4.1.231.2.10.2.666 | NodesieScBootRetryCountZero | This trap will be sent when a boot retry counter gets zero on power up | ||
| 1.3.6.1.4.1.231.2.10.2.667 | NodesieScMessageLogFull | The System Event Log is full. No more messages can be logged. This trap will not occur on wrap-around log types. | ||
| 1.3.6.1.4.1.231.2.10.2.668 | NodememErrorModulePrefailure | A memory module is predicted to fail (prefailure). | ||
| 1.3.6.1.4.1.231.2.10.2.669 | NodememErrorModuleFailing | A memory module is failing. | ||
| 1.3.6.1.4.1.231.2.10.2.670 | NodememErrorModuleReplaced | A memory module had failed and was replaced by a hot-spare module. | ||
| 1.3.6.1.4.1.231.2.10.2.671 | NodesniScPowerSupplyRedundancyLost | Power supply redundancy no longer available. | ||
| 1.3.6.1.4.1.231.2.10.2.672 | NodesieScMessageLogWarning | The warning threshold for the number of System Event Log entries has been exceeded. | ||
| 1.3.6.1.4.1.231.2.10.2.673 | NodesieScCpuPrefailure | A CPU is predicted to fail (prefailure). | ||
| 1.3.6.1.4.1.231.2.10.2.674 | NodesieScPowerFail | DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs. | ||
| 1.3.6.1.4.1.231.2.10.2.675 | NodesieScBiosSelftestError | A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition. | ||
| 1.3.6.1.4.1.231.2.10.2.676 | NodesieScBiosSelftestWatchdogExpired | This trap will be sent when the BIOS selftest watchdog expires. This watchdog expires when the BIOS selftest cannot be finished in a certain time period. | ||
| 1.3.6.1.4.1.231.2.10.2.677 | NodesniScVoltageFailure | Power supply voltage is out of range. | ||
| 1.3.6.1.4.1.231.2.10.2.678 | NodesniScBatteryVoltagePrefailure | Battery is predicted to fail. | ||
| 1.3.6.1.4.1.231.2.10.2.679 | NodesieScSevereSystemError | The system was restarted after a severe problem. See server management message log (recovery log) for detailed information. | ||
| 1.3.6.1.4.1.231.2.10.5 | NodesniTrapMib |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING | ||
| PhysAddress | OCTET STRING |