MIB Viewer

SNMP540-MGMT-MIB

58 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498.8.4Nodesnmp540
1.3.6.1.4.1.498.8.4.1Scalarsnmp540MIBversionread-onlymandatoryIdentifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y'identifies the minor revision number,…
1.3.6.1.4.1.498.8.4.2Nodesnmp540Config
1.3.6.1.4.1.498.8.4.2.1Scalarsnmp540ActivateCfgread-writemandatoryThe Activate configuration object. The value noChange(1), will maintain the old dataset configuration without saving any changes. The value activateNewCfg(2), …
1.3.6.1.4.1.498.8.4.2.2Scalarsnmp540DtePortTyperead-writemandatoryThe value auto(3) indicates that the electrical portion of the DTE interface is automatically detected. The rs232(1) value forces the DTE port to EIA/TIA-232-E…
1.3.6.1.4.1.498.8.4.2.3Nodesnmp540EiaTestControl
1.3.6.1.4.1.498.8.4.2.3.1Scalarsnmp540EiaRlcontrolread-writemandatoryThe RL Eia Test control lead option. This option either allows or blocks EIA initiated test inputs from the DTE interface.
1.3.6.1.4.1.498.8.4.2.3.2Scalarsnmp540EiaLlcontrolread-writemandatoryThe LL Eia Test control lead option. This option either allows or blocks EIA initiated test inputs from the DTE interface.
1.3.6.1.4.1.498.8.4.2.3.3Scalarsnmp540EiaTmcontrolread-writemandatoryThe Eia Test Mode lead option. This option controls the operation of the Test Mode output indication. A value of (1) allows the Test Mode output to indicate th…
1.3.6.1.4.1.498.8.4.2.3.4Scalarsnmp540LlbDetectread-writemandatoryThe Latching Loopback test detect option. This option controls the operation of the latching loopback detection. A value of (1) allows, the latching loopback t…
1.3.6.1.4.1.498.8.4.3Nodesnmp540Control
1.3.6.1.4.1.498.8.4.3.1Scalarsnmp540UnitResetread-writemandatoryThe value reset(2) will cause the snmp540 to perform a cold start. As soon as the object has been set to reset(2), the snmp540 will begin its reinitialization.…
1.3.6.1.4.1.498.8.4.4Nodesnmp540AlarmData
1.3.6.1.4.1.498.8.4.4.1Nodesnmp540PowerUpAlm
1.3.6.1.4.1.498.8.4.4.2Nodesnmp540CfgChkSumErrAlm
1.3.6.1.4.1.498.8.4.4.3Nodesnmp540StcLoopbackAlm
1.3.6.1.4.1.498.8.4.4.4Nodesnmp540NoNtwkLoopCurrentAlm
1.3.6.1.4.1.498.8.4.4.5Nodesnmp540LinePairsReversedAlm
1.3.6.1.4.1.498.8.4.4.6Nodesnmp540NoSignalAlm
1.3.6.1.4.1.498.8.4.4.7Nodesnmp540FpTestAlm
1.3.6.1.4.1.498.8.4.4.8Nodesnmp540DSRLossAlm
1.3.6.1.4.1.498.8.4.4.9Nodesnmp540DTRLossAlm
1.3.6.1.4.1.498.8.4.4.10Nodesnmp540DTPLossAlm
1.3.6.1.4.1.498.8.4.4.11Nodesnmp540DCDLossAlm
1.3.6.1.4.1.498.8.4.4.12Nodesnmp540RXDLossAlm
1.3.6.1.4.1.498.8.4.4.13Nodesnmp540TXDLossAlm
1.3.6.1.4.1.498.8.4.4.14Nodesnmp540JitterAlm
1.3.6.1.4.1.498.8.4.4.15Nodesnmp540BpvAlm
1.3.6.1.4.1.498.8.4.4.16Nodesnmp540FrameLossAlm
1.3.6.1.4.1.498.8.4.4.17Nodesnmp540SignalToNoiseAlm
1.3.6.1.4.1.498.8.4.4.18Nodesnmp540RxSignalLowAlm
1.3.6.1.4.1.498.8.4.5Nodesnmp540AlarmCfgThr
1.3.6.1.4.1.498.8.4.5.1Scalarsnmp540AlarmCfgCountWindowread-writemandatoryThis is the DDS Alarm Threshold Interval. It specifies the amount of time, 1 to 15 minutes, in which the threshold setting is to be exceeded for the alarm to o…
1.3.6.1.4.1.498.8.4.5.2Tablesnmp540AlarmCfgTablenot-accessiblemandatoryThe GDC snmp540 Alarm Configuration Table.
1.3.6.1.4.1.498.8.4.5.2.1Rowsnmp540AlarmCfgEntrynot-accessiblemandatoryAn entry in the snmp540 alarm table.
1.3.6.1.4.1.498.8.4.5.2.1.1Columnsnmp540AlarmCfgIdentifierread-onlymandatoryThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do…
1.3.6.1.4.1.498.8.4.5.2.1.2Columnsnmp540AlarmCfgThresholdread-writemandatoryThis function sets/reads the alarm threshold settings criteria. This threshold is used along with the alarm window to determine the number of instances in a gi…
1.3.6.1.4.1.498.8.4.6Nodesnmp540LineStats
1.3.6.1.4.1.498.8.4.6.1Scalarsnmp540LineStatsIntervalread-writemandatoryThe DDS Line Statistics Interval specifies the amount of LineStats data to be reported. Measurements are stored every minute and accumulated. The latest 15 min…
1.3.6.1.4.1.498.8.4.6.2Scalarsnmp540LineStatsTxLevelread-onlymandatoryTransmit level being generated into the private line circuit. This value is typically 6db.
1.3.6.1.4.1.498.8.4.6.3Scalarsnmp540LineStatsRxInterpretationread-onlymandatoryThis object the characterizes LineStats readings. Interpretation code Meaning ..................... ........................... noSignal(1) No line signal is b…
1.3.6.1.4.1.498.8.4.6.4Scalarsnmp540LineStatsRxLevelread-onlymandatoryThis object reports the receive level measurement for the selected interval. The range reported is from -50dB to +6dB.
1.3.6.1.4.1.498.8.4.6.5Scalarsnmp540LineStatsSignalToNoiseRatioread-onlymandatoryThis object will the report the signal to noise ratio ranging from 0db to 50db for the selected interval. The value is absolute. If RxInterpretation reports sT…
1.3.6.1.4.1.498.8.4.6.6Scalarsnmp540LineStatsSignalQualityread-onlymandatoryThis object reports the signal quality of the line, for the selected interval.
1.3.6.1.4.1.498.8.4.6.7Scalarsnmp540LineStatsJitterread-onlymandatoryThis object will the report the percent jitter of the line, for the selected interval.
1.3.6.1.4.1.498.8.4.6.8Scalarsnmp540LineStatsBpvCountread-onlymandatoryThis object will the report the number of bipolar violation codes received during for the selected LineStatsInterval.
1.3.6.1.4.1.498.8.4.6.9Scalarsnmp540LineStatsFrameLossCountread-onlymandatoryThis object will the report the number frame losses received for the selected LineStatsInterval.
1.3.6.1.4.1.498.8.4.7Nodesnmp540DiagTest
1.3.6.1.4.1.498.8.4.7.1Scalarsnmp540DiagTestPatternread-writemandatoryThe Self Test Pattern choices generated internally by the snmp540 are 511 Pattern (snmp540Send511Pattern(2)), 2047 pattern, (snmp540Send2047Pattern(3)) and 15 …
1.3.6.1.4.1.498.8.4.7.2Scalarsnmp540DiagTestExceptionsread-onlymandatoryIndicates exceptions that have occurred that may affect interpretation of the test results. The exception values are: value exception: ....... ................…
1.3.6.1.4.1.498.8.4.7.3Scalarsnmp540DiagBitErrorsread-onlymandatoryThe bit errors of the most recently run diagnostic test. If TestExceptions reports bitsOutOfRange, this object should be ignored.
1.3.6.1.4.1.498.8.4.7.4Scalarsnmp540DiagBlockErrorsread-onlymandatoryThe block errors of the most recently run diagnostic test.
1.3.6.1.4.1.498.8.4.7.5Scalarsnmp540RlLoopTyperead-writemandatoryThe value Pn127(1), will use a PN127 loopback sequence to initiate a remote loopback test. The value v54(2) will use a V54 loopback sequence to initiate a remo…
1.3.6.1.4.1.498.8.4.7.6Scalarsnmp540DiagBlocksToSendread-writemandatorySpecifies the number of test pattern blocks to generate during the test. The requested number of blocks are sent and checked during the test as a means of veri…
1.3.6.1.4.1.498.8.4.7.7Scalarsnmp540DiagControlread-writemandatoryThe lineloop(2) selection places the snmp540 into line loopback mode. The noTest(1) and telcoLoop(5) are READ ONLY values. NoTest(1) indicates that no diagnost…
1.3.6.1.4.1.498.8.4.8Nodesnmp540Led
1.3.6.1.4.1.498.8.4.8.1Scalarsnmp540LedStatusread-onlymandatory
1.3.6.1.4.1.498.8.4.9Scalarsnmp540DeviceSerialNumberread-onlymandatoryDisplay's the unique serial number of this device. The octet string starts with the two byte product code (0540) followed by a reserved byte value (rr) and the…