SPSv1-MIB
382 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.42610 | Nodepowertek | |||
| 1.3.6.1.4.1.42610.1 | Nodeproduct | |||
| 1.3.6.1.4.1.42610.1.4 | Nodepdu | |||
| 1.3.6.1.4.1.42610.1.4.4 | Nodesps | |||
| 1.3.6.1.4.1.42610.1.4.4.1 | NodepduObjects | |||
| 1.3.6.1.4.1.42610.1.4.4.1.1 | NodepduIdent | |||
| 1.3.6.1.4.1.42610.1.4.4.1.1.1 | ScalarpduIdentAgentSoftwareVersion | read-only | mandatory | The firmware version of the device. |
| 1.3.6.1.4.1.42610.1.4.4.1.1.2 | ScalarpduIdentSerialNumber | read-only | mandatory | A Model of this device. |
| 1.3.6.1.4.1.42610.1.4.4.1.2 | NodepduNetwork | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.1 | NodepduNetworkTcpip | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.1 | ScalarpduNetworkTcpipDhcpControl | read-write | mandatory | Enable/disable DHCP protocol |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.2 | NodepduNetworkTcpipIpv4 | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.2.1 | ScalarpduNetworkTcpipIpv4Address | read-write | mandatory | The ip address that NMS can identify the managed device. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.2.2 | ScalarpduNetworkTcpipIpv4Gateway | read-write | mandatory | The default gateway that allow device managed through routers. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.2.3 | ScalarpduNetworkTcpipIpv4Subnet | read-write | mandatory | Internet address subnet mask |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.2.4 | ScalarpduNetworkTcpipIpv4PrimaryDNS | read-write | mandatory | Internet address of Primary DNS Server |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.2.5 | ScalarpduNetworkTcpipIpv4SecondaryDNS | read-write | mandatory | Internet address of Secondary DNS |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3 | NodepduNetworkTcpipIpv6 | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.1 | ScalarpduNetworkTcpipIpv6Control | read-write | mandatory | Enable/disable IPv6 protocol |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.2 | ScalarpduNetworkTcpipIpv6AutoConfig | read-write | mandatory | IPv6 Auto-config or Maual setting |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.3 | ScalarpduNetworkTcpipIpv6Address | read-only | mandatory | The ipv6 address that NMS can identify the managed device. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.4 | ScalarpduNetworkTcpipIpv6Prefix | read-only | mandatory | The prefix length for ipv6 address. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.5 | ScalarpduNetworkTcpipIpv6Router | read-only | mandatory | The default gateway that allow device managed through routers. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.6 | ScalarpduNetworkTcpipIpv6PrimaryDNS | read-write | mandatory | Internet address of Primary DNS Server |
| 1.3.6.1.4.1.42610.1.4.4.1.2.1.3.7 | ScalarpduNetworkTcpipIpv6SecondaryDNS | read-write | mandatory | Internet address of Secondary DNS |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2 | NodepduNetworkSecurity | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.1 | ScalarpduNetworkSecurityControl | read-write | mandatory | Enable/disable Network Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.2 | NodepduNetworkSecuritySsh | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.2.1 | ScalarpduNetworkSecuritySshControl | read-write | mandatory | Enable/disable SSH Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.2.2 | ScalarpduNetworkSecuritySshInterval | read-write | mandatory | Detecting Interval of SSH Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.2.3 | ScalarpduNetworkSecuritySshFailTimes | read-write | mandatory | Unsuccessful attempts of SSH Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.2.4 | ScalarpduNetworkSecuritySshBlock | read-write | mandatory | Block Time of SSH Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.3 | NodepduNetworkSecuritySnmp | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.3.1 | ScalarpduNetworkSecuritySnmpControl | read-write | mandatory | Enable/disable SNMP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.3.2 | ScalarpduNetworkSecuritySnmpInterval | read-write | mandatory | Detecting Interval of SNMP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.3.3 | ScalarpduNetworkSecuritySnmpFailTimes | read-write | mandatory | Unsuccessful attempts of SNMP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.3.4 | ScalarpduNetworkSecuritySnmpBlock | read-write | mandatory | Block Time of SNMP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.4 | NodepduNetworkSecurityHttp | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.4.1 | ScalarpduNetworkSecurityHttpControl | read-write | mandatory | Enable/disable HTTP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.4.2 | ScalarpduNetworkSecurityHttpInterval | read-write | mandatory | Detecting Interval of HTTP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.4.3 | ScalarpduNetworkSecurityHttpFailTimes | read-write | mandatory | Unsuccessful attempts of HTTP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.2.4.4 | ScalarpduNetworkSecurityHttpBlock | read-write | mandatory | Block Time of HTTP Access Protection |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3 | NodepduNetworkService | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.1 | NodepduNetworkServiceSsh | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.1.1 | ScalarpduNetworkServiceSshControl | read-write | mandatory | Enable/disable SSH Server Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.1.2 | ScalarpduNetworkServiceSshPort | read-write | mandatory | The Port Number of SSH Server Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.2 | NodepduNetworkServiceSsl | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.2.1 | ScalarpduNetworkServiceSslControl | read-write | mandatory | Enable/disable HTTPs Server Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.2.2 | ScalarpduNetworkServiceSslPort | read-write | mandatory | The Port Number of HTTPs Server Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.2.3 | ScalarpduNetworkServiceSslForce | read-write | mandatory | Force use HTTPs Server Service only. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.3 | ScalarpduNetworkServicePingControl | read-write | mandatory | Enable/disable to response to PING request. |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4 | NodepduNetworkServiceRadius | |||
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4.1 | ScalarpduNetworkServiceRadiusControl | read-write | mandatory | Enable/disable RADIUS Client Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4.2 | ScalarpduNetworkServiceRadiusIp | read-write | mandatory | The IP Address of RADIUS Client Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4.3 | ScalarpduNetworkServiceRadiusPort | read-write | mandatory | The Port Number of RADIUS Client Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4.4 | ScalarpduNetworkServiceRadiusSecretKey | read-write | mandatory | The Secret Key of RADIUS Client Service |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4.5 | ScalarpduNetworkServiceRadiusTimeout | read-write | mandatory | The Timeout Interval of RADIUS Client Service in seconds |
| 1.3.6.1.4.1.42610.1.4.4.1.2.3.4.6 | ScalarpduNetworkServiceRadiusRetry | read-write | mandatory | The Retry Times of RADIUS Client Service |
| 1.3.6.1.4.1.42610.1.4.4.1.3 | NodepduSystem | |||
| 1.3.6.1.4.1.42610.1.4.4.1.3.1 | ScalarpduSystemName | read-write | mandatory | The name of system. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.2 | ScalarpduSystemContact | read-write | mandatory | The contact of system. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.3 | ScalarpduSystemLocation | read-write | mandatory | The location of system. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.4 | ScalarpduSystemLogInterval | read-write | mandatory | The Log Interval of device |
| 1.3.6.1.4.1.42610.1.4.4.1.3.5 | ScalarpduSystemWebRefresh | read-write | mandatory | The Web Refresh Interval of device |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6 | NodepduSystemTime | |||
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.1 | ScalarpduSystemTimeDisplay | read-only | mandatory | The date/time in agent |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.2 | ScalarpduSystemTimeZone | read-write | mandatory | Time Zone to use when synchronize with NTP server. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.3 | ScalarpduSystemTimeFormat | read-write | mandatory | Date Format |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.4 | ScalarpduSystemTimeSetting | read-write | mandatory | Time Setting |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.5 | ScalarpduSystemTimeDayLightSaving | read-write | mandatory | Enable/disable the Day Light Saving when synchronize with NTP server. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.6 | NodepduSystemTimeManual | |||
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.6.1 | ScalarpduSystemTimeManualDate | read-write | mandatory | The date in agent, format is (dd/mm/yyyy) |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.6.2 | ScalarpduSystemTimeManualTime | read-write | mandatory | The time in agent, format is (hh:mm:ss) |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.7 | NodepduSystemTimeNtp | |||
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.7.1 | ScalarpduSystemTimeNtpControl | read-write | mandatory | Enable or disable the agent to synchronize date/time with NTP server. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.7.2 | ScalarpduSystemTimeNtpServer | read-write | mandatory | The ip address of NTP server. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.7.3 | ScalarpduSystemTimeNtpSyncInterval | read-write | mandatory | The Sync Interval with NTP server. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.6.7.4 | ScalarpduSystemTimeNtpSyncUnit | read-write | mandatory | The Unit of Sync Interval |
| 1.3.6.1.4.1.42610.1.4.4.1.3.7 | ScalarpduSystemResetToDefault | read-write | mandatory | Reset the parameter of PDU to default. |
| 1.3.6.1.4.1.42610.1.4.4.1.3.8 | ScalarpduSystemReboot | read-write | mandatory | Reboot the system of PDU. |
| 1.3.6.1.4.1.42610.1.4.4.1.4 | NodepduSNMP | |||
| 1.3.6.1.4.1.42610.1.4.4.1.4.1 | ScalarpduSnmpControl | read-write | mandatory | Enable/disable SNMP protocol. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.2 | ScalarpduSnmpPort | read-write | mandatory | The UDP port for SNMP. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.3 | ScalarpduSnmpVersion | read-write | mandatory | Set SNMP version. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4 | TablepduSnmpTrapsReceiversTable | not-accessible | mandatory | A list of managers to send traps to. The number of entries is given by the value of pduSnmpNumTrapReceivers |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4.1 | RowpduSnmpTrapsReceiversEntry | not-accessible | mandatory | The managers to send traps to. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4.1.1 | ColumntrapsIndex | read-only | mandatory | The index to a trap receiver entry. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4.1.2 | ColumntrapsReceiverAddr | read-write | mandatory | The IP address of the manager to send a trap to. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4.1.3 | ColumnreceiverEventLevel | read-write | mandatory | The severity level of traps to be received by this manager. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4.1.4 | ColumnreceiverSnmpVer | read-write | mandatory | The SNMP Trap version of trap receivers. |
| 1.3.6.1.4.1.42610.1.4.4.1.4.4.1.5 | ColumnreceiverDescription | read-write | mandatory | Description of trap receivers |
| 1.3.6.1.4.1.42610.1.4.4.1.5 | NodepduEmail | |||
| 1.3.6.1.4.1.42610.1.4.4.1.5.1 | ScalarpduEmailServer | read-write | mandatory | The address of Email server. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.2 | ScalarpduEmailPort | read-write | mandatory | The UDP port for Email Server. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.3 | ScalarpduEmailSenderEmail | read-write | mandatory | The sender's Email address |
| 1.3.6.1.4.1.42610.1.4.4.1.5.4 | ScalarpduEmailPrefix | read-write | mandatory | The prefix string of mail subject |
| 1.3.6.1.4.1.42610.1.4.4.1.5.5 | ScalarpduEmailAuthControl | read-write | mandatory | Enable/disable SMTP Authentication. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.6 | ScalarpduEmailAuthUsername | read-write | mandatory | The user name of SMTP Authentication |
| 1.3.6.1.4.1.42610.1.4.4.1.5.7 | ScalarpduEmailAuthPassword | read-write | mandatory | The password of SMTP Authentication |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8 | TablepduEmailReceiversTable | not-accessible | mandatory | A list of managers to send email notification to. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8.1 | RowpduEmailReceiversEntry | not-accessible | mandatory | The managers to send email notification to. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8.1.1 | ColumnmailRecvIndex | read-only | mandatory | The index to a email notification receiver entry. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8.1.2 | ColumnmailRecvReceiverAddr | read-write | mandatory | The Email address of the manager to send a email notification to. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8.1.3 | ColumnmailRecvEmailType | read-write | mandatory | The Email Type of email notification receivers. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8.1.4 | ColumnmailRecvEventLevel | read-write | mandatory | The severity level of email notification to be received by this manager. |
| 1.3.6.1.4.1.42610.1.4.4.1.5.8.1.5 | ColumnmailRecvDescription | read-write | mandatory | Description of email notification receivers |
| 1.3.6.1.4.1.42610.1.4.4.1.6 | NodepduPwrMonitoring | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.1 | NodepduPwrMonitoringInlet | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.1 | ScalarpduPwrMonitoringInletNum | read-only | mandatory | The number of Inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2 | TablepduPwrMonitoringInletStatusTable | not-accessible | mandatory | A list to display status of Inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1 | RowpduPwrMonitoringInletStatusEntry | not-accessible | mandatory | A list to display status of Inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.1 | ColumninletIndex | read-only | mandatory | The index to Inlet status entry. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.2 | ColumninletPowerAll | read-only | mandatory | The total power of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.3 | ColumninletResetFrom | read-only | mandatory | The reset date of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.4 | ColumninletEnergy | read-only | mandatory | The total energy of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.5 | ColumninletStatus | read-only | mandatory | The Status of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.6 | ColumninletCurrPhase1 | read-only | mandatory | The phase1 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.7 | ColumninletCurrPhase2 | read-only | mandatory | The phase2 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.8 | ColumninletCurrPhase3 | read-only | mandatory | The phase3 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.9 | ColumninletVoltPhase1 | read-only | mandatory | The phase1 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.10 | ColumninletVoltPhase2 | read-only | mandatory | The phase2 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.11 | ColumninletVoltPhase3 | read-only | mandatory | The phase3 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.12 | ColumninletPwrFactorPhase1 | read-only | mandatory | The phase1 power factor of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.13 | ColumninletPwrFactorPhase2 | read-only | mandatory | The phase2 power factor of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.14 | ColumninletPwrFactorPhase3 | read-only | mandatory | The phase3 power factor of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.15 | ColumninletPowerPhase1 | read-only | mandatory | The phase1 power of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.16 | ColumninletPowerPhase2 | read-only | mandatory | The phase2 power of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.17 | ColumninletPowerPhase3 | read-only | mandatory | The phase3 power of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.18 | ColumninletStatusPhase1 | read-only | mandatory | The phase1 status of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.19 | ColumninletStatusPhase2 | read-only | mandatory | The phase2 status of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.20 | ColumninletStatusPhase3 | read-only | mandatory | The phase3 status of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3 | TablepduPwrMonitoringInletCfgTable | not-accessible | mandatory | A list to configure thresholds of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1 | RowpduPwrMonitoringInletCfgEntry | not-accessible | mandatory | A list to configure thresholds of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.1 | ColumninletCfgIndex | read-only | mandatory | The index to inlet configuration entry. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.2 | ColumninletCfgLoadCritical | read-write | mandatory | The Critical Threshold of inlet load. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.3 | ColumninletCfgLoadWarning | read-write | mandatory | The Warning Threshold of inlet load. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.4 | ColumninletCfgCurrCritPhase1 | read-write | mandatory | The Critical Threshold of pahse1 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.5 | ColumninletCfgCurrCritPhase2 | read-write | mandatory | The Critical Threshold of pahse2 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.6 | ColumninletCfgCurrCritPhase3 | read-write | mandatory | The Critical Threshold of pahse3 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.7 | ColumninletCfgCurrWarnPhase1 | read-write | mandatory | The Warning Threshold of pahse1 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.8 | ColumninletCfgCurrWarnPhase2 | read-write | mandatory | The Warning Threshold of pahse2 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.9 | ColumninletCfgCurrWarnPhase3 | read-write | mandatory | The Warning Threshold of pahse3 current of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.10 | ColumninletCfgVoltCritPhase1 | read-write | mandatory | The Critical Threshold of pahse1 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.11 | ColumninletCfgVoltCritPhase2 | read-write | mandatory | The Critical Threshold of pahse2 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.12 | ColumninletCfgVoltCritPhase3 | read-write | mandatory | The Critical Threshold of pahse3 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13 | ColumninletCfgVoltWarnPhase1 | read-write | mandatory | The Warning Threshold of pahse1 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.14 | ColumninletCfgVoltWarnPhase2 | read-write | mandatory | The Warning Threshold of pahse2 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.15 | ColumninletCfgVoltWarnPhase3 | read-write | mandatory | The Warning Threshold of pahse3 voltage of inlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2 | NodepduPwrMonitoringOutlet | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1 | NodepduPwrMonitoringOutletPduA | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.1 | ScalarpduPwrMonitoringOutletNumPduA | read-only | mandatory | The number of PduA Outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2 | TablepduPwrMonitoringOutletStatusTablePduA | not-accessible | mandatory | A list to display status of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1 | RowpduPwrMonitoringOutletStatusPduAEntry | not-accessible | mandatory | A list to display status of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.1 | ColumnoutletPduAIndex | read-only | mandatory | The index to outlet status of PduA. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.2 | ColumnoutletPduAState | read-only | mandatory | The state of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.3 | ColumnoutletPduACurrent | read-only | mandatory | The current of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.4 | ColumnoutletPduAPwrFactor | read-only | mandatory | The power factor of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.5 | ColumnoutletPduAPower | read-only | mandatory | The power of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.6 | ColumnoutletPduAEnergy | read-only | mandatory | The energy of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.7 | ColumnoutletPduAResetFrom | read-only | mandatory | The reset date of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.8 | ColumnoutletPduAStatus | read-only | mandatory | The status of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3 | TablepduPwrMonitoringOutletCfgTablePduA | not-accessible | mandatory | A list to display configuration of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1 | RowpduPwrMonitoringOutletCfgPduAEntry | not-accessible | mandatory | A list to display configuration of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.1 | ColumnoutletCfgPduAIndex | read-only | mandatory | The index to outlet configuration of PduA. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.2 | ColumnoutletCfgPduAName | read-write | mandatory | The name for outlet of PduA. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.3 | ColumnoutletCfgPduADelayOnStatus | read-write | mandatory | The Delay On status of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.4 | ColumnoutletCfgPduADelayOnTime | read-write | mandatory | The Delay On time of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.5 | ColumnoutletCfgPduADelayOffStatus | read-write | mandatory | The Delay Off status of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.6 | ColumnoutletCfgPduADelayOffTime | read-write | mandatory | The Delay Off time of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.7 | ColumnoutletCfgPduAReboot | read-write | mandatory | The Delay On reboot duration of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.8 | ColumnoutletCfgPduAOverCurrCritical | read-write | mandatory | The Critical Threshold of current of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.9 | ColumnoutletCfgPduAOverCurrWarning | read-write | mandatory | The Warning Threshold of current of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.10 | ColumnoutletCfgPduAOverPwrCritical | read-write | mandatory | The Critical Threshold of power of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.11 | ColumnoutletCfgPduAOverPwrWarning | read-write | mandatory | The Warning Threshold of power of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4 | TablepduPwrMonitoringOutletCtlTablePduA | not-accessible | mandatory | A list to display control of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4.1 | RowpduPwrMonitoringOutletCtlPduAEntry | not-accessible | mandatory | A list to display control of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4.1.1 | ColumnoutletCtlPduAIndex | read-only | mandatory | The index to outlet control of PduA. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4.1.2 | ColumnoutletCtlPduAControl | read-write | mandatory | The control-type of PduA outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2 | NodepduPwrMonitoringOutletPduB | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.1 | ScalarpduPwrMonitoringOutletNumPduB | read-only | mandatory | The number of PduB Outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2 | TablepduPwrMonitoringOutletStatusTablePduB | not-accessible | mandatory | A list to display status of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1 | RowpduPwrMonitoringOutletStatusPduBEntry | not-accessible | mandatory | A list to display status of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.1 | ColumnoutletPduBIndex | read-only | mandatory | The index to outlet status of PduB. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.2 | ColumnoutletPduBState | read-only | mandatory | The state of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.3 | ColumnoutletPduBCurrent | read-only | mandatory | The current of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.4 | ColumnoutletPduBPwrFactor | read-only | mandatory | The power factor of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.5 | ColumnoutletPduBPower | read-only | mandatory | The power of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.6 | ColumnoutletPduBEnergy | read-only | mandatory | The energy of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.7 | ColumnoutletPduBResetFrom | read-only | mandatory | The reset date of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.8 | ColumnoutletPduBStatus | read-only | mandatory | The status of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3 | TablepduPwrMonitoringOutletCfgTablePduB | not-accessible | mandatory | A list to display configuration of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1 | RowpduPwrMonitoringOutletCfgPduBEntry | not-accessible | mandatory | A list to display configuration of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.1 | ColumnoutletCfgPduBIndex | read-only | mandatory | The index to outlet configuration of PduB. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.2 | ColumnoutletCfgPduBName | read-write | mandatory | The name for outlet of PduB. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.3 | ColumnoutletCfgPduBDelayOnStatus | read-write | mandatory | The Delay On status of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.4 | ColumnoutletCfgPduBDelayOnTime | read-write | mandatory | The Delay On time of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.5 | ColumnoutletCfgPduBDelayOffStatus | read-write | mandatory | The Delay Off status of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.6 | ColumnoutletCfgPduBDelayOffTime | read-write | mandatory | The Delay Off time of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.7 | ColumnoutletCfgPduBReboot | read-write | mandatory | The Delay On reboot duration of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.8 | ColumnoutletCfgPduBOverCurrCritical | read-write | mandatory | The Critical Threshold of current of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.9 | ColumnoutletCfgPduBOverCurrWarning | read-write | mandatory | The Warning Threshold of current of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.10 | ColumnoutletCfgPduBOverPwrCritical | read-write | mandatory | The Critical Threshold of power of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.11 | ColumnoutletCfgPduBOverPwrWarning | read-write | mandatory | The Warning Threshold of power of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4 | TablepduPwrMonitoringOutletCtlTablePduB | not-accessible | mandatory | A list to display control of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4.1 | RowpduPwrMonitoringOutletCtlPduBEntry | not-accessible | mandatory | A list to display control of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4.1.1 | ColumnoutletCtlPduBIndex | read-only | mandatory | The index to outlet control of PduB. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4.1.2 | ColumnoutletCtlPduBControl | read-write | mandatory | The control-type of PduB outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3 | NodepduPwrMonitoringOutletPduC | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.1 | ScalarpduPwrMonitoringOutletNumPduC | read-only | mandatory | The number of PduC Outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2 | TablepduPwrMonitoringOutletStatusTablePduC | not-accessible | mandatory | A list to display status of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1 | RowpduPwrMonitoringOutletStatusPduCEntry | not-accessible | mandatory | A list to display status of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.1 | ColumnoutletPduCIndex | read-only | mandatory | The index to outlet status of PduC. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.2 | ColumnoutletPduCState | read-only | mandatory | The state of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.3 | ColumnoutletPduCCurrent | read-only | mandatory | The current of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.4 | ColumnoutletPduCPwrFactor | read-only | mandatory | The power factor of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.5 | ColumnoutletPduCPower | read-only | mandatory | The power of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.6 | ColumnoutletPduCEnergy | read-only | mandatory | The energy of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.7 | ColumnoutletPduCResetFrom | read-only | mandatory | The reset date of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.8 | ColumnoutletPduCStatus | read-only | mandatory | The status of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3 | TablepduPwrMonitoringOutletCfgTablePduC | not-accessible | mandatory | A list to display configuration of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1 | RowpduPwrMonitoringOutletCfgPduCEntry | not-accessible | mandatory | A list to display configuration of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.1 | ColumnoutletCfgPduCIndex | read-only | mandatory | The index to outlet configuration of PduC. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.2 | ColumnoutletCfgPduCName | read-write | mandatory | The name for outlet of PduC. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.3 | ColumnoutletCfgPduCDelayOnStatus | read-write | mandatory | The Delay On status of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4 | ColumnoutletCfgPduCDelayOnTime | read-write | mandatory | The Delay On time of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.5 | ColumnoutletCfgPduCDelayOffStatus | read-write | mandatory | The Delay Off status of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.6 | ColumnoutletCfgPduCDelayOffTime | read-write | mandatory | The Delay Off time of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.7 | ColumnoutletCfgPduCReboot | read-write | mandatory | The Delay On reboot duration of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.8 | ColumnoutletCfgPduCOverCurrCritical | read-write | mandatory | The Critical Threshold of current of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.9 | ColumnoutletCfgPduCOverCurrWarning | read-write | mandatory | The Warning Threshold of current of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.10 | ColumnoutletCfgPduCOverPwrCritical | read-write | mandatory | The Critical Threshold of power of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.11 | ColumnoutletCfgPduCOverPwrWarning | read-write | mandatory | The Warning Threshold of power of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4 | TablepduPwrMonitoringOutletCtlTablePduC | not-accessible | mandatory | A list to display control of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1 | RowpduPwrMonitoringOutletCtlPduCEntry | not-accessible | mandatory | A list to display control of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.1 | ColumnoutletCtlPduCIndex | read-only | mandatory | The index to outlet control of PduC. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2 | ColumnoutletCtlPduCControl | read-write | mandatory | The control-type of PduC outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4 | NodepduPwrMonitoringOutletPduD | |||
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.1 | ScalarpduPwrMonitoringOutletNumPduD | read-only | mandatory | The number of PduD Outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2 | TablepduPwrMonitoringOutletStatusTablePduD | not-accessible | mandatory | A list to display status of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1 | RowpduPwrMonitoringOutletStatusPduDEntry | not-accessible | mandatory | A list to display status of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.1 | ColumnoutletPduDIndex | read-only | mandatory | The index to outlet status of PduD. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.2 | ColumnoutletPduDState | read-only | mandatory | The state of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.3 | ColumnoutletPduDCurrent | read-only | mandatory | The current of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.4 | ColumnoutletPduDPwrFactor | read-only | mandatory | The power factor of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.5 | ColumnoutletPduDPower | read-only | mandatory | The power of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.6 | ColumnoutletPduDEnergy | read-only | mandatory | The energy of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.7 | ColumnoutletPduDResetFrom | read-only | mandatory | The reset date of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.8 | ColumnoutletPduDStatus | read-only | mandatory | The status of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3 | TablepduPwrMonitoringOutletCfgTablePduD | not-accessible | mandatory | A list to display configuration of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1 | RowpduPwrMonitoringOutletCfgPduDEntry | not-accessible | mandatory | A list to display configuration of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.1 | ColumnoutletCfgPduDIndex | read-only | mandatory | The index to outlet configuration of PduD. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.2 | ColumnoutletCfgPduDName | read-write | mandatory | The name for outlet of PduD. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.3 | ColumnoutletCfgPduDDelayOnStatus | read-write | mandatory | The Delay On status of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.4 | ColumnoutletCfgPduDDelayOnTime | read-write | mandatory | The Delay On time of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.5 | ColumnoutletCfgPduDDelayOffStatus | read-write | mandatory | The Delay Off status of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.6 | ColumnoutletCfgPduDDelayOffTime | read-write | mandatory | The Delay Off time of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.7 | ColumnoutletCfgPduDReboot | read-write | mandatory | The Delay On reboot duration of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.8 | ColumnoutletCfgPduDOverCurrCritical | read-write | mandatory | The Critical Threshold of current of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.9 | ColumnoutletCfgPduDOverCurrWarning | read-write | mandatory | The Warning Threshold of current of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.10 | ColumnoutletCfgPduDOverPwrCritical | read-write | mandatory | The Critical Threshold of power of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.11 | ColumnoutletCfgPduDOverPwrWarning | read-write | mandatory | The Warning Threshold of power of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4 | TablepduPwrMonitoringOutletCtlTablePduD | not-accessible | mandatory | A list to display control of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4.1 | RowpduPwrMonitoringOutletCtlPduDEntry | not-accessible | mandatory | A list to display control of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4.1.1 | ColumnoutletCtlPduDIndex | read-only | mandatory | The index to outlet control of PduD. |
| 1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4.1.2 | ColumnoutletCtlPduDControl | read-write | mandatory | The control-type of PduD outlet. |
| 1.3.6.1.4.1.42610.1.4.4.1.7 | NodepduEnvMonitoring | |||
| 1.3.6.1.4.1.42610.1.4.4.1.7.1 | NodepduEnvMonitoringStatus | |||
| 1.3.6.1.4.1.42610.1.4.4.1.7.1.1 | ScalarpduEnvMonitoringTemp | read-only | mandatory | The temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.1.2 | ScalarpduEnvMonitoringHumi | read-only | mandatory | The humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.1.3 | ScalarpduEnvMonitoringTempAlarm | read-only | mandatory | The temperature status of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.1.4 | ScalarpduEnvMonitoringHumiAlarm | read-only | mandatory | The humidity status of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2 | NodepduEnvMonitoringCfg | |||
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.1 | ScalarpduEnvMonitoringControl | read-write | mandatory | Enable/disable the EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.2 | ScalarpduEnvMonitoringTempHighCritical | read-write | mandatory | The High Critical Threshold of temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.3 | ScalarpduEnvMonitoringTempHighWarning | read-write | mandatory | The High Warning Threshold of temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.4 | ScalarpduEnvMonitoringTempLowCritical | read-write | mandatory | The Low Critical Threshold of temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.5 | ScalarpduEnvMonitoringTempLowWarning | read-write | mandatory | The Low Warning Threshold of temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.6 | ScalarpduEnvMonitoringTempHystersis | read-write | mandatory | The Hystersis of Temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.7 | ScalarpduEnvMonitoringTempOffset | read-write | mandatory | The Offset of Temperature of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.8 | ScalarpduEnvMonitoringHumiHighCritical | read-write | mandatory | The High Crtitcal Threshold of humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.9 | ScalarpduEnvMonitoringHumiHighWarning | read-write | mandatory | The High Warning Threshold of humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.10 | ScalarpduEnvMonitoringHumiLowCritical | read-write | mandatory | The Low Crtitcal Threshold of humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.11 | ScalarpduEnvMonitoringHumiLowWarning | read-write | mandatory | The Low Warning Threshold of humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.12 | ScalarpduEnvMonitoringHumiHystersis | read-write | mandatory | The Hystersis of Humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.1.7.2.13 | ScalarpduEnvMonitoringHumiOffset | read-write | mandatory | The Ofset of Humidity of EMD. |
| 1.3.6.1.4.1.42610.1.4.4.2 | NodepduTraps | |||
| 1.3.6.1.4.1.42610.1.4.4.2.1 | NodepduSystemColdBoot | Informational: Cold boot. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.2 | NodepduSystemWarmBoot | Informational: Warm boot. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.3 | NodepduSystemRestart | Informational: System restart. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.4 | NodepduResetToDefault | Informational: Parameters reset to default. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.5 | NodepduFirmUpgrade | Informational: Firmware upgrade. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.6 | NodepduSystemLogClear | Informational: System log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.7 | NodepduEventlogClear | Informational: Event log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.8 | NodepduInletHistoryClear | Informational: Inlet history log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.9 | NodepduOutletHistoryClear | Informational: Outlet history log cleared. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.10 | NodepduSystemTimeChangeUser | Informational: Time changed by user. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.11 | NodepduSystemTimeChangeNtp | Informational: Time synced with NTP server. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.12 | NodepduSystemTimeChangeRtc | Informational: Time changed by RTC. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.13 | NodepduMailTestPass | Informational: Test mail pass. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.14 | NodepduMailTestFail | Informational: Test mail failed. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.15 | NodepduMailSentPass | Informational: Mail sent successfully. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.16 | NodepduMailSentFail | Informational: Mail sent failed. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.17 | NodepduSystemCfgChange | Informational: Parameter changed. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.18 | NodepduSystemParamImport | Informational: Import XML configuration. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.19 | NodepduInletCommLost | Informational: Inlet communication lost. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.20 | NodepduInletCommRestore | Informational: Inlet communication restore. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.21 | NodepduOutletCommLost | Informational: Outlet communication lost. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.22 | NodepduOutletCommRestore | Informational: Outlet communication restore | ||
| 1.3.6.1.4.1.42610.1.4.4.2.23 | NodepduOutletOnUser | Informational: Outlet turned on by user. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.24 | NodepduOutletOnSchedule | Informational: Outlet turned on by schedule. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.25 | NodepduOutletOffUser | Informational: Outlet turned off by user. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.26 | NodepduOutletOffSchedule | Informational: Outlet turned off by schedule. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.27 | NodepduOutletRebootUser | Informational: Outlet reboot by user. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.28 | NodepduOutletRebootSchedule | Informational: Outlet reboot by schedule. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.29 | NodepduInletEnergyReset | Informational: Inlet energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.30 | NodepduOutletEnergyReset | Informational: Outlet energy reset. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.31 | NodepduSetUser | Informational: Assign outlet to user. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.32 | NodepduDeletUser | Informational: Delete user. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.33 | NodepduUpgradeInletSuccess | Informational: Inlet upgrade successfully. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.34 | NodepduUpgradeInletFail | Informational: Inlet upgrade fail. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.35 | NodepduUpgradeOutletSuccess | Informational: Outlet upgrade successfully. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.36 | NodepduUpgradeOutletFail | Informational: Outlet upgrade fail. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.101 | NodepduEmdTempHighWarnToNormal | Informational: Temperature had returned from high warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.102 | NodepduEmdTempHighWarn | Warning: Temperature was higher than high warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.103 | NodepduEmdTempLowWarnToNormal | Informational: Temperature had returned from low warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.104 | NodepduEmdTempLowWarn | Warning: Temperature was lower than low warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.105 | NodepduEmdTempHighCritToWarn | Informational: Temperature had returned from high critical to high warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.106 | NodepduEmdTempHighCritical | Critical: Temperature was higher than high critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.107 | NodepduEmdTempLowCritToWarn | Informational: Temperature had returned from low critical to low warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.108 | NodepduEmdTempLowCritical | Critical: Temperature was lower than low critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.109 | NodepduEmdHumiHighWarnToNormal | Informational: Humidity had returned from high warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.110 | NodepduEmdHumiHighWarn | Warning: Humidity was higher than high warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.111 | NodepduEmdHumiLowWarnToNormal | Informational: Humidity had returned from low warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.112 | NodepduEmdHumiLowWarn | Warning: Humidity was lower than low warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.113 | NodepduEmdHumiHighCritToWarn | Informational: Humidity had returned from high critical to high warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.114 | NodepduEmdHumiHighCritical | Critical: Humidity was higher than high critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.115 | NodepduEmdHumiLowCritToWarn | Informational: Humidity had returned from low critical to low warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.116 | NodepduEmdHumiLowCritical | Critical: Humidity was lower than low critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.117 | NodepduEmdAlarm1NotActive | Informational: Alarm-1 became inactive. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.118 | NodepduEmdAlarm1Active | Warning: Alarm-1 became active. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.119 | NodepduEmdAlarm2NotActive | Informational: Alarm-2 became inactive. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.120 | NodepduEmdAlarm2Active | Warning: Alarm-2 became active. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.121 | NodepduRs485Online | Informational: RS485 Sensor was online. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.122 | NodepduRs485Offline | Warning: RS485 Sensor was offline. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.123 | NodepduInletLoadCritToWarn | Informational: Inlet load had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.124 | NodepduInletLoadCritical | Critical: Inlet load was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.125 | NodepduInletLoadWarnToNormal | Informational: Inlet load had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.126 | NodepduInletLoadWarn | Warning: Inlet load was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.127 | NodepduInletCurrPhase1CritToWarn | Informational: Inlet phase1 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.128 | NodepduInletCurrPhase1Critical | Critical: Inlet phase1 current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.129 | NodepduInletCurrPhase1WarnToNormal | Informational: Inlet phase1 current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.130 | NodepduInletCurrPhase1Warn | Warning: Inlet phase1 current was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.131 | NodepduInletCurrPhase2CritToWarn | Informational: Inlet phase2 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.132 | NodepduInletCurrPhase2Critical | Critical: Inlet phase2 current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.133 | NodepduInletCurrPhase2WarnToNormal | Informational: Inlet phase2 current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.134 | NodepduInletCurrPhase2Warn | Warning: Inlet phase2 current was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.135 | NodepduInletCurrPhase3CritToWarn | Informational: Inlet phase3 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.136 | NodepduInletCurrPhase3Critical | Critical: Inlet phase3 current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.137 | NodepduInletCurrPhase3WarnToNormal | Informational: Inlet phase3 current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.138 | NodepduInletCurrPhase3Warn | Warning: Inlet phase3 current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.139 | NodepduInletVoltPhase1CritToWarn | Informational: Inlet phase1 voltage had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.140 | NodepduInletVoltPhase1Critical | Critical: Inlet phase1 voltage was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.141 | NodepduInletVoltPhase1WarnToNormal | Informational: Inlet phase1 voltage had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.142 | NodepduInletVoltPhase1Warn | Warning: Inlet phase1 voltage was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.143 | NodepduInletVoltPhase2CritToWarn | Informational: Inlet phase2 voltage had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.144 | NodepduInletVoltPhase2Critical | Critical: Inlet phase2 voltage was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.145 | NodepduInletVoltPhase2WarnToNormal | Informational: Inlet phase2 voltage had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.146 | NodepduInletVoltPhase2Warn | Warning: Inlet phase2 voltage was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.147 | NodepduInletVoltPhase3CritToWarn | Informational: Inlet phase3 voltage had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.148 | NodepduInletVoltPhase3Critical | Critical: Inlet phase3 voltage was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.149 | NodepduInletVoltPhase3WarnToNormal | Informational: Inlet phase3 voltage had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.150 | NodepduInletVoltPhase3Warn | Warning: Inlet phase3 voltage was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.151 | NodepduOutletCurrCritToWarn | Informational: Outlet current had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.152 | NodepduOutletCurrCritical | Critical: Outlet current was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.153 | NodepduOutletCurrWarnToNormal | Informational: Outlet current had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.154 | NodepduOutletCurrWarn | Warning: Outlet current was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.155 | NodepduOutletPwrCritTOWarn | Informational: Outlet power had returned from critical to warning. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.156 | NodepduOutletPwrCritical | Critical: Outlet power was higher than critical set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.157 | NodepduOutletPwrWarnToNormal | Informational: Outlet power had returned from warning to normal. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.158 | NodepduOutletPwrWarn | Warning: Outlet power was higher than warning set point. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.159 | NodepduAlarm1Disabled | Informational: Alarm-1 became disabled. | ||
| 1.3.6.1.4.1.42610.1.4.4.2.160 | NodepduAlarm2Disabled | Informational: Alarm-2 became disabled. |