SRM-MIB
17 objects
No module-level DESCRIPTION found.
Imported Objects
| BASIS-MIB | cardSpecific |
| RFC-1212 | OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.351.110.3.10 | Nodesrm3T3CnfGrp | |||
| 1.3.6.1.4.1.351.110.3.10.1 | Tablesrm3T3CnfGrpTable | not-accessible | mandatory | The SRM 3T3 configuration table, it is the distribution of a T3 line. |
| 1.3.6.1.4.1.351.110.3.10.1.1 | Rowsrm3T3CnfGrpEntry | not-accessible | mandatory | an entry in the T3 configuration table |
| 1.3.6.1.4.1.351.110.3.10.1.1.1 | ColumnsrmT3LineNum | read-only | mandatory | Select T3 line number. There is no default value for this object. |
| 1.3.6.1.4.1.351.110.3.10.1.1.2 | ColumnsrmStartT1LineNum | read-only | mandatory | The start T1 number to be affected. There is no default value for this object. |
| 1.3.6.1.4.1.351.110.3.10.1.1.3 | ColumnsrmT1RowStatus | read-write | mandatory | a command is used to add, delete, or modify one or more DS1 mapping. Default value is delete. |
| 1.3.6.1.4.1.351.110.3.10.1.1.4 | ColumnsrmTargetSlotNum | read-write | mandatory | specify the target slot number to be linked. There is no default value for this object. For MGX8850: SRM01 services slots 1 - 6 and 9 - 14, SRM02 services slot… |
| 1.3.6.1.4.1.351.110.3.10.1.1.5 | ColumnsrmTargetSlotLineNum | read-write | mandatory | 0 means not assigned. There is no default value for this object. |
| 1.3.6.1.4.1.351.110.3.22 | NodesrmeCnfGrp | |||
| 1.3.6.1.4.1.351.110.3.22.1 | TablesrmeCnfGrpTable | not-accessible | mandatory | The SRME configuration table for bulk distribution of SRME lines. |
| 1.3.6.1.4.1.351.110.3.22.1.1 | RowsrmeCnfGrpEntry | not-accessible | mandatory | an entry in the SRME Distribution configuration table |
| 1.3.6.1.4.1.351.110.3.22.1.1.1 | ColumnsrmeLineNum | read-only | mandatory | Select SRME line number. For OC3/STM1: SYNTAX INTEGER 1 There is no default value for this object. |
| 1.3.6.1.4.1.351.110.3.22.1.1.2 | ColumnsrmeStartVtNum | read-only | mandatory | The start T1 or E1 number (virtual tributary) to be affected. For OC3 with T1 tributaries: SYNTAX INTEGER (1 .. 84) For STM1 with E1 tributaries: SYNTAX INTEGE… |
| 1.3.6.1.4.1.351.110.3.22.1.1.3 | ColumnsrmeRowStatus | read-write | mandatory | Command used to add, delete, or modify one or more T1 or E1 mappings. Only the srmeVtFramingType object can be modified once the distribution link is added. To… |
| 1.3.6.1.4.1.351.110.3.22.1.1.4 | ColumnsrmeTargetSlotNum | read-write | mandatory | specify the target slot number to be linked. There is no default value for this object. For MGX8x50: SRM01 services slots 1 - 6 and 9 - 14, SRM02 services slot… |
| 1.3.6.1.4.1.351.110.3.22.1.1.5 | ColumnsrmeTargetSlotLineNum | read-write | mandatory | Specify the target slot's line to be linked. 0 means not assigned. There is no default value for this object. |
| 1.3.6.1.4.1.351.110.3.22.1.1.6 | ColumnsrmeVtFramingType | read-write | mandatory | Specifies the Framing Type of the target slot line. This is applicable only if the target module is a T1 Service Module and byte sync mapping is used on SRME. … |