MIB Viewer

SRM-MIB

17 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.351.110.3.10Nodesrm3T3CnfGrp
1.3.6.1.4.1.351.110.3.10.1Tablesrm3T3CnfGrpTablenot-accessiblemandatoryThe SRM 3T3 configuration table, it is the distribution of a T3 line.
1.3.6.1.4.1.351.110.3.10.1.1Rowsrm3T3CnfGrpEntrynot-accessiblemandatoryan entry in the T3 configuration table
1.3.6.1.4.1.351.110.3.10.1.1.1ColumnsrmT3LineNumread-onlymandatorySelect T3 line number. There is no default value for this object.
1.3.6.1.4.1.351.110.3.10.1.1.2ColumnsrmStartT1LineNumread-onlymandatoryThe start T1 number to be affected. There is no default value for this object.
1.3.6.1.4.1.351.110.3.10.1.1.3ColumnsrmT1RowStatusread-writemandatorya command is used to add, delete, or modify one or more DS1 mapping. Default value is delete.
1.3.6.1.4.1.351.110.3.10.1.1.4ColumnsrmTargetSlotNumread-writemandatoryspecify the target slot number to be linked. There is no default value for this object. For MGX8850: SRM01 services slots 1 - 6 and 9 - 14, SRM02 services slot…
1.3.6.1.4.1.351.110.3.10.1.1.5ColumnsrmTargetSlotLineNumread-writemandatory0 means not assigned. There is no default value for this object.
1.3.6.1.4.1.351.110.3.22NodesrmeCnfGrp
1.3.6.1.4.1.351.110.3.22.1TablesrmeCnfGrpTablenot-accessiblemandatoryThe SRME configuration table for bulk distribution of SRME lines.
1.3.6.1.4.1.351.110.3.22.1.1RowsrmeCnfGrpEntrynot-accessiblemandatoryan entry in the SRME Distribution configuration table
1.3.6.1.4.1.351.110.3.22.1.1.1ColumnsrmeLineNumread-onlymandatorySelect SRME line number. For OC3/STM1: SYNTAX INTEGER 1 There is no default value for this object.
1.3.6.1.4.1.351.110.3.22.1.1.2ColumnsrmeStartVtNumread-onlymandatoryThe start T1 or E1 number (virtual tributary) to be affected. For OC3 with T1 tributaries: SYNTAX INTEGER (1 .. 84) For STM1 with E1 tributaries: SYNTAX INTEGE…
1.3.6.1.4.1.351.110.3.22.1.1.3ColumnsrmeRowStatusread-writemandatoryCommand used to add, delete, or modify one or more T1 or E1 mappings. Only the srmeVtFramingType object can be modified once the distribution link is added. To…
1.3.6.1.4.1.351.110.3.22.1.1.4ColumnsrmeTargetSlotNumread-writemandatoryspecify the target slot number to be linked. There is no default value for this object. For MGX8x50: SRM01 services slots 1 - 6 and 9 - 14, SRM02 services slot…
1.3.6.1.4.1.351.110.3.22.1.1.5ColumnsrmeTargetSlotLineNumread-writemandatorySpecify the target slot's line to be linked. 0 means not assigned. There is no default value for this object.
1.3.6.1.4.1.351.110.3.22.1.1.6ColumnsrmeVtFramingTyperead-writemandatorySpecifies the Framing Type of the target slot line. This is applicable only if the target module is a T1 Service Module and byte sync mapping is used on SRME. …