SS-OPT-MIB
49 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | enterprises |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.2 | Nodecdx6500CfgGeneralGroup | |||
| 1.3.6.1.4.1.449.2.1.2.2.14 | Tablecdx6500GCTLSSTable | not-accessible | mandatory | A list of Configuration parameters that makeup the Switched Service/LBU Table. |
| 1.3.6.1.4.1.449.2.1.2.2.14.1 | Rowcdx6500SSCfgEntry | not-accessible | mandatory | Each entry contains the Configuration parameters for each switched Service/backup link. |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.1 | Columncdx6500SSEntryNumber | read-only | mandatory | This identifies the particular Switched Service/LBU Table entry being configured. The number of instances defined by this entry depends on the configured value… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.2 | Columncdx6500SSDestinationName | read-only | mandatory | This is a unique name that identifies this entry. |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.3 | Columncdx6500SSCfgMonitoredPort | read-only | mandatory | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The format must be the following: X25-n… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.4 | Columncdx6500SSCfgRestoralPort | read-only | mandatory | This is the port or channel that acts as the backup when there is a port failure on the port specified by the parameter Monitored port, or primary destination … |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.5 | Columncdx6500SSDialSequence | read-only | mandatory | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, use any combination of the foll… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.6 | Columncdx6500SSActivationMode | read-only | mandatory | This specifies how the switched service/backup port will be activated. fail - Activate the backup port upon link failure. call - Activate the backup port upon … |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.7 | Columncdx6500SSDeactivationMode | read-only | mandatory | This specifies how the switched service/backup port is deactivated after the original link is up. none - Backup port can only be deactivated by operator interv… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.8 | Columncdx6500SSLinkHoldTime | read-only | mandatory | This replaces the value of the parameter Idle Disconnect Timer in the X.25 Port Record and specifies how long (in seconds) the backup link remains active after… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.9 | Columncdx6500SSOutBoundPass | read-only | mandatory | This is the password used by the remote station to determine if dial access is authorized. |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.10 | Columncdx6500SSRedialTime | read-only | mandatory | This is the time in seconds between dial attempts when bringing up a switched service call. |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.11 | Columncdx6500SSRedialCounter | read-only | mandatory | This parameter is used to specify the number of times that the Switched Service will attempt to redial when redial timer is expired. A value of zero will allow… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.12 | Columncdx6500SSSecurityMode | read-only | mandatory | This specifies under what conditions the port/channel authorizes call request. none - A call request not be rejected based on password of calling party id vali… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.13 | Columncdx6500SSSetupTime | read-only | mandatory | This is the time in seconds the monitor port(s) are given to come up after node boot before the backup port is activated. |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.14 | Columncdx6500SSCfgMonitoredPort2 | read-only | mandatory | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The format must be the following: X25-n… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.15 | Columncdx6500SSCfgMonitoredPort3 | read-only | mandatory | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The format must be the following: X25-n… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.16 | Columncdx6500SSCfgMonitoredPort4 | read-only | mandatory | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The format must be the following: X25-n… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.17 | Columncdx6500SSDialSequence2 | read-only | mandatory | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, use any combination of the foll… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.18 | Columncdx6500SSDialSequence3 | read-only | mandatory | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, use any combination of the foll… |
| 1.3.6.1.4.1.449.2.1.2.2.14.1.19 | Columncdx6500SSDialSequence4 | read-only | mandatory | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, use any combination of the foll… |
| 1.3.6.1.4.1.449.2.1.2.2.18 | Tablecdx6500CallIDTable | not-accessible | mandatory | A list of Configuration calling ID that makeup the Calling ID Table. |
| 1.3.6.1.4.1.449.2.1.2.2.18.1 | Rowcdx6500CallIDEntry | not-accessible | mandatory | Each entry contains the Configuration Calling ID. |
| 1.3.6.1.4.1.449.2.1.2.2.18.1.1 | Columncdx6500CallIDEntryNumber | read-only | mandatory | This is not a configurable parameter. This identifies the particular calling ID Table entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.18.1.2 | Columncdx6500CallIDString | read-only | mandatory | Each calling id entry is a numeric value which may contain periods or dashes. Only calls matching these ids will be allowed when calling id security is enabled. |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.2 | Nodecdx6500StatOtherStatsGroup | |||
| 1.3.6.1.4.1.449.2.1.3.2.3 | Tablecdx6500OSTSSTable | not-accessible | mandatory | A list of statistics parameters for the Switch Service/Link Backup port,station,and channel. |
| 1.3.6.1.4.1.449.2.1.3.2.3.1 | Rowcdx6500SSStatEntry | not-accessible | mandatory | Each entry on this table pertains to the Switched Service/Link Backup port,station and channel, and can be accessed using the following index: the switched/bac… |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.1 | Columncdx6500SSStatRestoralPort | read-only | mandatory | This is the backup port number, used as an index to access Switched Service/LBU statistics. |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.2 | Columncdx6500SSPortType | read-only | mandatory | The port type of the backup port. |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.3 | Columncdx6500SSConnType | read-only | mandatory | The connection type of the backup port. |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.4 | Columncdx6500SSStatus | read-only | mandatory | The status of the backup port. newvalDown - same functionality as 'down', new enumeration added for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.5 | Columncdx6500SSReason | read-only | mandatory | The reason that the backup port is active. none : Backup port is deactivated. call : A call request was made on the backup port. fail : Due to a link failure o… |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.6 | Columncdx6500SSRedial | read-only | mandatory | This parameter is used to specify the number of times that the Switched Service will attempt to redial when the redial timer is expired. A value of zero will a… |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.7 | Columncdx6500SSLastActivated | read-only | mandatory | The last time the backup port was activated. |
| 1.3.6.1.4.1.449.2.1.3.2.3.1.8 | Columncdx6500SSLastPhoneDialed | read-only | mandatory | The phone number dialed the last time the backup port was activated. |
| 1.3.6.1.4.1.449.2.1.3.2.4 | Tablecdx6500OSTSSMonTable | not-accessible | mandatory | A list of statistics parameters for the Link Backup's monitored port. |
| 1.3.6.1.4.1.449.2.1.3.2.4.1 | Rowcdx6500SSMonStatEntry | not-accessible | mandatory | Each entry on this table pertains to one of the monitored ports/station/channel that is monitored by the backup port/ station/channel and should be accessed us… |
| 1.3.6.1.4.1.449.2.1.3.2.4.1.1 | Columncdx6500SSStatRestMonPort | read-only | mandatory | This is the backup port number, used as a primary index to access monitored port statistics. |
| 1.3.6.1.4.1.449.2.1.3.2.4.1.2 | Columncdx6500SSStatMonitoredPort | read-only | mandatory | This is the port being monitored by the backup port, used as a secondary index to access monitored port statistics. |
| 1.3.6.1.4.1.449.2.1.3.2.4.1.3 | Columncdx6500SSMonPortState | read-only | mandatory | State of the monitored port. newvalDown : same functionality as 'down', new enumeration added for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.3.2.4.1.4 | Columncdx6500SSRestPhoneNum | read-only | mandatory | Phone number that the backup port will dial when a monitored port has a link failure. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |