MIB Viewer

SS7I-MIB

72 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.429Nodeusr
1.3.6.1.4.1.429.1Nodenas
1.3.6.1.4.1.429.1.35Nodess7i
1.3.6.1.4.1.429.1.35.1Nodess7iCfg
1.3.6.1.4.1.429.1.35.1.1Tabless7iCfgTablenot-accessiblemandatoryThe Configuration Table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It contains objects that reflect the current configuratio…
1.3.6.1.4.1.429.1.35.1.1.1Rowss7iCfgEntrynot-accessiblemandatoryThere is one Configuration Table entry per HiPer SS7i Card in the chassis.
1.3.6.1.4.1.429.1.35.1.1.1.1Columnss7iCfgIndexread-onlymandatoryA unique value for each HiPer SS7i card in the chassis. The value of ss7iCfgIndex matches the value of the index for the corresponding HiPer SS7i card entity i…
1.3.6.1.4.1.429.1.35.1.1.1.2Columnss7iCfgIpAddrread-writemandatoryThe IP address on interface 0 of the HiPer SS7i.
1.3.6.1.4.1.429.1.35.1.1.1.3Columnss7iCfgNetmaskread-writemandatoryThe netmask on interface 0 of the HiPer SS7i.
1.3.6.1.4.1.429.1.35.1.1.1.4Columnss7iCfgDfltGwIpAddrread-writemandatoryThe IP address of the default IP routing gateway.
1.3.6.1.4.1.429.1.35.1.1.1.5Columnss7iCfgProtocolread-writemandatoryThe external signaling protocol running over the TCP/IP connection with the external signaling gateway. Default = hss7iSlapV2(1).
1.3.6.1.4.1.429.1.35.1.1.1.6Columnss7iCfgGwConnStartMethodread-writemandatoryThe method used by the HiPer SS7i to bring up the TCP/IP connection to the external signaling gateway at boot time.
1.3.6.1.4.1.429.1.35.1.1.1.7Columnss7iCfgGwIpAddrread-writemandatoryThe primary external SS7 gateway IP address. Valid for SLAP only.
1.3.6.1.4.1.429.1.35.1.1.1.8Columnss7iCfgGwPortread-writemandatoryThe primary external SS7 gateway port number. Valid for SLAP only.
1.3.6.1.4.1.429.1.35.1.1.1.9Columnss7iCfgSecGwIpAddrread-writemandatoryThe secondary external SS7 gateway IP address. Valid for SLAP only.
1.3.6.1.4.1.429.1.35.1.1.1.10Columnss7iCfgSecGwPortread-writemandatoryThe secondary external SS7 gateway port number. Valid for SLAP only.
1.3.6.1.4.1.429.1.35.1.1.1.11Columnss7iCfgHrtbtTimerNearEndread-writemandatoryThe HiPer SS7i heartbeat timer. Upon expiration, the HiPer SS7i will send a heartbeat message to the external SS7 gateway. The time should be less than what th…
1.3.6.1.4.1.429.1.35.1.1.1.12Columnss7iCfgHrtbtTimerFarEndread-writemandatoryThe external SS7 gateway heartbeat timer. Upon expiration it causes the HiPer SS7i to commence the connection re-establishment procedure to the external SS7 ga…
1.3.6.1.4.1.429.1.35.1.1.1.13Columnss7iCfgChassisIdread-writemandatoryThis uniquely identifies logical Chassis under the control of the HiPer SS7I, valid for SLAP only. The OCTET STRING format must be FF FF FF FF .
1.3.6.1.4.1.429.1.35.1.1.1.14Columnss7iCfgGwConnRetryCntread-writemandatoryThe number of times the HiPer SS7i will attempt to re-establish the TCP/IP connection to the external SS7 gateway after the initial failure was detected. Valid…
1.3.6.1.4.1.429.1.35.1.1.1.15Columnss7iCfgGwConnRetryIntvlread-writemandatoryThe time interval between attempts of the HiPer SS7i to re-establish the TCP/IP connection to the external SS7 gateway. Valid for SLAP only. Default = 2 sec.
1.3.6.1.4.1.429.1.35.1.1.1.16Columnss7iCfgGwMssdHrtbtThrshread-writemandatoryThe number of external SS7 gateway heartbeat timeouts allowed before the connection to the gateway is considered lost. A setting of 0 means no attempt will be …
1.3.6.1.4.1.429.1.35.2Nodess7iCmd
1.3.6.1.4.1.429.1.35.2.1Tabless7iCmdTablenot-accessiblemandatoryThe Command table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It provides a means through which to take specific actions on t…
1.3.6.1.4.1.429.1.35.2.1.1Rowss7iCmdEntrynot-accessiblemandatoryThere is one Command Table entry per HiPer SS7i card in the chassis.
1.3.6.1.4.1.429.1.35.2.1.1.1Columnss7iCmdIndexread-onlymandatoryA unique value for each HiPer SS7i card in the chassis. The value of this object matches the value of the index of the corresponding HiPer SS7i card's entry in…
1.3.6.1.4.1.429.1.35.2.1.1.2Columnss7iCmdMgtStationIdread-writemandatoryThis object is a generic read-write variable that a Management Station (MS) can use to guarantee that the results from a given command are the results of a com…
1.3.6.1.4.1.429.1.35.2.1.1.3Columnss7iCmdReqIdread-onlymandatoryThis object contains the value of the request-id field in the SNMP PDU which invoked the current or most recent command or test on this HiPer SS7i card. If the…
1.3.6.1.4.1.429.1.35.2.1.1.4Columnss7iCmdFunctionread-writemandatoryThis object contains a value which describes the command which is being invoked.
1.3.6.1.4.1.429.1.35.2.1.1.5Columnss7iCmdForceread-writemandatoryIn some cases, the HiPer SS7i card may be in a state such that certain commands could adversely affect connections. In such cases, a command request with this …
1.3.6.1.4.1.429.1.35.2.1.1.6Columnss7iCmdParamread-writemandatoryThis object contains parameters that are specific to the particular command being issued. In some cases, there will be no aditional parameters required.
1.3.6.1.4.1.429.1.35.2.1.1.7Columnss7iCmdResultread-onlymandatoryThis object contains the result of the most recently requested command or test, or the value none(1) if no commands have been requested since the last reset.
1.3.6.1.4.1.429.1.35.2.1.1.8Columnss7iCmdCoderead-onlymandatoryThe value of this object upon command completion indicates a further description of what went wrong if the command was unsuccessful. In the case of tests, a bi…
1.3.6.1.4.1.429.1.35.3Nodess7iTrap
1.3.6.1.4.1.429.1.35.3.1Tabless7iTrapTablenot-accessiblemandatoryTable containing objects to enable traps on the HiPer SS7i cards in the chassis.
1.3.6.1.4.1.429.1.35.3.1.1Rowss7iTrapEntrynot-accessiblemandatoryThere is one entry for each HiPer SS7i card in the chassis.
1.3.6.1.4.1.429.1.35.3.1.1.1Columnss7iTrapIndexread-onlymandatoryA unique index identifying the HiPer SS7i card to which the trap enable objects pertain.
1.3.6.1.4.1.429.1.35.3.1.1.2Columnss7iTrapPbusLinkUpread-writemandatoryEnables reporting of a trap and/or log message when the ENFAS packet bus signaling link to the HiPer Dsp comes up. Default = disableAll(2).
1.3.6.1.4.1.429.1.35.3.1.1.3Columnss7iTrapPbusLinkDownread-writemandatoryEnables reporting of a trap and/or log message when the ENFAS packet bus signaling link to the HiPer Dsp goes down. Default = disableAll(2).
1.3.6.1.4.1.429.1.35.3.1.1.4Columnss7iTrapGwConnUpread-writemandatoryEnables reporting of a trap and/or log message when the TCP/IP signaling connection to the SS7 (or media) gateway comes up. Default = disableAll(2).
1.3.6.1.4.1.429.1.35.3.1.1.5Columnss7iTrapGwConnDownread-writemandatoryEnables reporting of a trap and/or log message when the TCP/IP signaling connection to the SS7 (or media) gateway goes down. Default = disableAll(2).
1.3.6.1.4.1.429.1.35.4Nodess7iStat
1.3.6.1.4.1.429.1.35.4.1Tabless7iStatTablenot-accessiblemandatoryThe Statistics table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It contains objects that reflect the current status of the c…
1.3.6.1.4.1.429.1.35.4.1.1Rowss7iStatEntrynot-accessiblemandatoryThere is one Statistics table entry for each HiPer SS7i card in the chassis.
1.3.6.1.4.1.429.1.35.4.1.1.1Columnss7iStatIndexread-onlymandatoryA unique value for each HiPer SS7i card in the chassis. The value of ss7iStatIndex matches the value of the index for the corresponding Hiper SS7i card entity …
1.3.6.1.4.1.429.1.35.4.1.1.2Columnss7iStatGwConnStatusread-onlymandatoryStatus of the TCP/IP connection with the external signaling gateway. Valid for SLAP only.
1.3.6.1.4.1.429.1.35.4.1.1.3Columnss7iStatGwNumMsgsRcvdread-onlymandatoryThe number of messages received from the external SS7 gateway or the Media Gateway Controller.
1.3.6.1.4.1.429.1.35.4.1.1.4Columnss7iStatGwNumBytesRcvdread-onlymandatoryThe number of bytes received from the external SS7 gateway or the Media Gateway Controller.
1.3.6.1.4.1.429.1.35.4.1.1.5Columnss7iStatGwNumMsgsSentread-onlymandatoryThe number of messages sent to the external SS7 gateway or the Media Gateway Controller.
1.3.6.1.4.1.429.1.35.4.1.1.6Columnss7iStatGwNumBytesSentread-onlymandatoryThe number of bytes sent to the external SS7 gateway or the Media Gateway Controller.
1.3.6.1.4.1.429.1.35.4.1.1.7Columnss7iStatGwMssdHrtbtCntread-onlymandatoryThe accumulated number of missed heartbeat messages expected to arrive from the external SS7 gateway.
1.3.6.1.4.1.429.1.35.4.1.1.8Columnss7iStatGwLinkLostCntread-onlymandatoryThe accumulated number of times the physical Ethernet connection is unplugged or severed.
1.3.6.1.4.1.429.1.35.4.1.1.9Columnss7iStatGwLinkErrCntread-onlymandatoryThe accumulated number of errors encountered sending to or receiving from the external SS7 gateway when the TCP/IP connection is believed to be healthy.
1.3.6.1.4.1.429.1.35.4.1.1.10Columnss7iStatGwLinkDownCauseread-onlymandatoryThe reason the signaling connection to the external SS7 gateway went down.
1.3.6.1.4.1.429.1.35.5Nodess7iHdm
1.3.6.1.4.1.429.1.35.5.1Tabless7iHdmTablenot-accessiblemandatoryThe ss7iHdm table contains objects for all of the HiPer Dsp cards in the chassis.
1.3.6.1.4.1.429.1.35.5.1.1Rowss7iHdmEntrynot-accessiblemandatoryThere is one entry for each HiPer Dsp Card in the chassis.
1.3.6.1.4.1.429.1.35.5.1.1.1Columnss7iHdmIndexread-onlymandatoryA unique value for each HiPer SS7i card in the chassis. The value of ss7iHdmIndex matches the value of the index for the corresponding HiPer SS7i card entity i…
1.3.6.1.4.1.429.1.35.5.1.1.2Columnss7iHdmIndex2read-onlymandatoryThe secondary index into the ss7iHdm table. There is one entry for each Hiper Dsp in the chassis. The value of the index is equal to the chassis slot number of…
1.3.6.1.4.1.429.1.35.5.1.1.3Columnss7iHdmConnStateread-onlymandatoryThe state of the signaling packet bus connection to the HiPer Dsp. There is one connection from the HiPer SS7i card to each HiPer Dsp in the chassis.
1.3.6.1.4.1.429.1.35.5.1.1.4Columnss7iHdmSndPktsOkCntread-onlymandatoryThe number of packets successfully transmitted over the signaling packet bus connection.
1.3.6.1.4.1.429.1.35.5.1.1.5Columnss7iHdmSndPktsFailCntread-onlymandatoryThe number of packets failing to transmit over the signaling packet bus connection.
1.3.6.1.4.1.429.1.35.5.1.1.6Columnss7iHdmRcvPktsOkCntread-onlymandatoryThe number of packets sucessfully received over the signaling packet bus connection.
1.3.6.1.4.1.429.1.35.5.1.1.7Columnss7iHdmRcvPktsFailCntread-onlymandatoryThe number of signaling packet bus connection packets rejected by the HiPer SS7i message handler.
1.3.6.1.4.1.429.1.35.5.1.1.8Columnss7iHdmLinkDownCauseread-onlymandatoryThe reason the packet bus ENFAS signaling link to the HiPer Dsp went down.
1.3.6.1.4.1.429.1.35.6Nodess7iSigPb
1.3.6.1.4.1.429.1.35.6.1Tabless7iSigPbTablenot-accessiblemandatoryThe ss7iSigPb table contains objects for managing the signaling packet bus connections to all of the HiPer Dsp cards in the chassis.
1.3.6.1.4.1.429.1.35.6.1.1Rowss7iSigPbEntrynot-accessiblemandatoryThere is one entry for each HiPer Dsp Card in the chassis.
1.3.6.1.4.1.429.1.35.6.1.1.1Columnss7iSigPbIndexread-onlymandatoryA unique value for each HiPer SS7i card in the chassis. The value of ss7iSigPbIndex matches the value of the index for the corresponding HiPer SS7i card entity…
1.3.6.1.4.1.429.1.35.6.1.1.2Columnss7iSigPbIndex2read-onlymandatoryThe secondary index into the ss7iSigPb table. There is one entry for each Hiper Dsp in the chassis. The value of the index is equal to the chassis slot number …
1.3.6.1.4.1.429.1.35.6.1.1.3Columnss7iSigPbConnectionread-writemandatoryThe means to enable or disable a signaling packet bus connection between the HiPer SS7i and a Hiper Dsp. Default = disable(1).
1.3.6.1.4.1.429.1.35.6.1.1.4Columnss7iSigPbLoopbackread-writemandatoryThe means to enable or disable the loopback state on the signaling packet bus connection between the HiPer SS7i and a Hiper Dsp. Default = disable(1).