MIB Viewer

SicamRTUs

46 objects
The SICAM RTUs MIB module for managing settings of the SIEMENS SICAM RTUs.
Imported Objects
SIEMENS-SMIsicamRTUs
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.22638.7.1IdentitygeneralInfoThe SICAM RTUs MIB module for managing settings of the SIEMENS SICAM RTUs.
1.3.6.1.4.1.22638.7.1.1NodeauConfigurationOverview
1.3.6.1.4.1.22638.7.1.1.1Scalarplantread-onlycurrentPlant name of the automation unit
1.3.6.1.4.1.22638.7.1.1.2ScalarplantIDread-onlycurrentPlant id of the automation unit
1.3.6.1.4.1.22638.7.1.1.3Scalarregionread-onlycurrentRegion number of the automation unit (0 .. 249)
1.3.6.1.4.1.22638.7.1.1.4Scalarcomponentread-onlycurrentComponent number of the automation unit (0 .. 255)
1.3.6.1.4.1.22638.7.1.1.5Scalardeviceread-onlycurrentDevice name of the automation unit
1.3.6.1.4.1.22638.7.1.2NodefirmwareRevision
1.3.6.1.4.1.22638.7.1.2.1TablefirmwareRevisionTablenot-accessiblecurrent
1.3.6.1.4.1.22638.7.1.2.1.1RowfirmwareRevisionEntrynot-accessiblecurrentAn entry in the list of last send SICAM RTUs firmware revision
1.3.6.1.4.1.22638.7.1.2.1.1.1ColumnrIndexread-onlycurrentIndex of last send SICAM RTUs firmware information
1.3.6.1.4.1.22638.7.1.2.1.1.2ColumnrInstanceread-onlycurrentInstance of the system element
1.3.6.1.4.1.22638.7.1.2.1.1.3ColumnrNameread-onlycurrentName of the system element
1.3.6.1.4.1.22638.7.1.2.1.1.4ColumnrRevisionread-onlycurrentFirmware revision of the system element
1.3.6.1.4.1.22638.7.1.2.1.1.5ColumnrDescriptionread-onlycurrentDescription of the system element
1.3.6.1.4.1.22638.7.1.2.1.1.6ColumnrBseSseread-onlycurrentAddress of the system element
1.3.6.1.4.1.22638.7.1.2.1.1.7ColumnrHwNrread-onlycurrentHardware number of the system element
1.3.6.1.4.1.22638.7.1.2.1.1.8ColumnrFwNrread-onlycurrentFirmware number of the system element
1.3.6.1.4.1.22638.7.10Nodediagnostic
1.3.6.1.4.1.22638.7.10.1NodesumDiagnosticTable
1.3.6.1.4.1.22638.7.10.1.1ScalarclassInternalread-onlycurrentAre errors, that can be unequivocally traced back to system elements in the automation unit (Firmware or Hardware).
1.3.6.1.4.1.22638.7.10.1.2ScalarclassExternalread-onlycurrentAre errors, that are detected through monitoring the information from sensors and actuators. They can concern the peripheral element, the wiring and sensors or…
1.3.6.1.4.1.22638.7.10.1.3ScalarclassCommunicationread-onlycurrentAre errors, that are detected by protocol elements and result from the monitoring of the communication line, insofar as the source of error can not be unequivo…
1.3.6.1.4.1.22638.7.10.1.4ScalarclassTestread-onlycurrentTest means, that a clearly assigned function is in test; e.g. Online-Test of the Open-/Closed- Loop Control Function.
1.3.6.1.4.1.22638.7.10.1.5ScalarclassWarningread-onlycurrentWarning indicates, that the system is still functioning, but has limited functionality or availability, e.g. parameter error, poor line quality, external minut…
1.3.6.1.4.1.22638.7.10.1.6ScalarclassBoardFailureread-onlycurrentSignals, that the internal communication with a system element is no longer possible and will be created by the monitoring basic system element.
1.3.6.1.4.1.22638.7.10.1.7ScalarclassFailureread-onlycurrentSignals, that an automation unit can no longer be reached and will be created by the monitoring automation unit.
1.3.6.1.4.1.22638.7.10.1.8ScalarclassStartUpread-onlycurrentSignals, that the automation unit or the system element has started up following Power-Up or Reset.
1.3.6.1.4.1.22638.7.10.1.9ScalarclassParameterread-onlycurrentParameter error indicates, that actual device configuration is inconsistent or invalid.
1.3.6.1.4.1.22638.7.10.1.10ScalarclassHWConfread-onlycurrentSignals, that the device detected an internal or external hardware failure.
1.3.6.1.4.1.22638.7.10.10NodesumDiagnosticTraps
1.3.6.1.4.1.22638.7.10.10.1NotificationdiagnosticEventcurrentSICAM RTUs sum diagnostic events inform about current state of all modules of the SICAM RTU.
1.3.6.1.4.1.22638.7.10.10.2ScalardiagnosticClassaccessible-for-notifycurrentDiagnostic Class: 1 - 10 depending on type of diagnostic event and correlating with objects of sumDiagnosticTable. Class 1 is an internal error, Class 2 is an …
1.3.6.1.4.1.22638.7.10.10.3ScalardiagnosticConditionaccessible-for-notifycurrentCondition: 0 = going event / 1 = coming event
1.3.6.1.4.1.22638.7.10.10.4ScalardiagnosticDateread-onlycurrentThe local date and time of day when event occurs.
1.3.6.1.4.1.22638.7.11Nodehistory
1.3.6.1.4.1.22638.7.11.1TabletrapHistoryTablenot-accessiblecurrentList of last send SICAM RTUs traps including cold start trap, link up/down traps and SICAM RTUs sum diagnostic events
1.3.6.1.4.1.22638.7.11.1.1RowtrapHistoryEntrynot-accessiblecurrentAn entry in the list of last send SICAM RTUs traps
1.3.6.1.4.1.22638.7.11.1.1.1ColumntrapHistoryIndexread-onlycurrentIndex of last send SICAM RTUs traps
1.3.6.1.4.1.22638.7.11.1.1.2ColumntrapHistoryTrapDateread-onlycurrentThe local date and time of day when trap occurs.
1.3.6.1.4.1.22638.7.11.1.1.3ColumntrapHistoryTrapOIDread-onlycurrentThe traps OID
1.3.6.1.4.1.22638.7.11.1.1.4ColumntrapHistoryTrapStateread-onlycurrentThe traps condition: 0 = event is going / 1 = event is coming
1.3.6.1.4.1.22638.7.11.1.1.5ColumntrapHistoryTrapArg1read-onlycurrentAn additional variable of the trap
1.3.6.1.4.1.22638.7.11.1.1.6ColumntrapHistoryTrapArg2read-onlycurrentAn additional variable of the trap
1.3.6.1.4.1.22638.7.11.1.1.7ColumntrapHistoryTrapArg3read-onlycurrentAn additional variable of the trap
Type Definitions
NameSyntaxStatusDescription
DateAndTimeOCTET STRING (SIZE (8 | 11))