TELDAT-CFG-INTERF-IEC101GW-MIB

24 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2007.4.1.1.4.16NodetelProdNpConfInterfIec101GW
1.3.6.1.4.1.2007.4.1.1.4.16.1TabletelProdNpIec101GWTablenot-accessiblemandatoryTable of global configuration for IEC101 GW interfaces. Each row represents an interface
1.3.6.1.4.1.2007.4.1.1.4.16.1.1RowtelProdNpIec101GWEntrynot-accessiblemandatoryA base list of objects that are configuration information about an IEC101 GW interface. The index is the number of the interface.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.1ColumntelProdNpIec101GWIfcIndexread-onlymandatoryIEC101-GW interface index. It is the index table.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.2ColumntelProdNpIec101GWIfcAsduCAddrread-writemandatorySet RTU ASDU common Adress for no multilink mode.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.3ColumntelProdNpIec101GWIfcBaudRateread-writemandatorySet baud reate for serial interface.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.4ColumntelProdNpIec101GWIfcLinkAddrread-writemandatorySet RTU Link Adress for no multilink mode.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.5ColumntelProdNpIec101GWIfcLinkAddrSzread-writemandatorySet Link Adress field size.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.6ColumntelProdNpIec101GWIfcLongRespread-writemandatoryEnable sends long frame responses to RTU's.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.7ColumntelProdNpIec101GWIfcMultilinkread-writemandatoryEnable RTU's multilink mode.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.8ColumntelProdNpIec101GWIfcBuffNumread-writemandatoryConfigure number of IEC-101 transmission buffers.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.9ColumntelProdNpIec101GWIfcOrigAddrread-writemandatoryConfigure IEC-101 Originator Address.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.10ColumntelProdNpIec101GWIfcRetransMaxread-writemandatoryConfigure maximum number of IEC-101 messages retransmissions.
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.11ColumntelProdNpIec101GWIfcRetransTimeread-writemandatoryConfigure time for IEC-101 messages retransmissions. Time in milliseconds
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.12ColumntelProdNpIec101GWIfcRxTimeoutread-writemandatoryConfigure input frame timeout. Time in milliseconds
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.13ColumntelProdNpIec101GWIfcSyncTimeread-writemandatoryConfigure period time to sent IEC-101 Synchronization message to RTU. Time in minutes
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.14ColumntelProdNpIec101GWIfcTestTimeread-writemandatoryConfigure period time to sent IEC-101 Link Test message to RTU. Time in seconds
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15ColumntelProdNpIec101GWIfcTestTyperead-writemandatoryConfigure type of IEC-101 Link Test message to send to RTU. 0 Don't send message, 1 Send Test message, 2 Send Status message.
1.3.6.1.4.1.2007.4.1.1.4.16.2TabletelProdNpIec101GWIfcRtuTablenot-accessiblemandatoryTable of RTU Link Address configuration for IEC101 GW interfaces. There are two table indexes: the interface and the RTU index.
1.3.6.1.4.1.2007.4.1.1.4.16.2.1RowtelProdNpIec101GWIfcRtuEntrynot-accessiblemandatoryEach entry contains an RTU link address. Each entry consist on an interfece index and an RTU index.
1.3.6.1.4.1.2007.4.1.1.4.16.2.1.1ColumntelProdNpIec101GWIfcRtuIfcIndexread-onlymandatoryIEC101-GW interface index. It is the index table.
1.3.6.1.4.1.2007.4.1.1.4.16.2.1.2ColumntelProdNpIec101GWIfcRtuIndexread-onlymandatoryRTU table index.
1.3.6.1.4.1.2007.4.1.1.4.16.2.1.3ColumntelProdNpIec101GWIfcRtuStatusread-writemandatoryTable control variable. Set to 1 does nothing. Set to 2 adds a new row (RTU link address) in the table with default value(65534) and returns 2. If it already e…
1.3.6.1.4.1.2007.4.1.1.4.16.2.1.4ColumntelProdNpIec101GWIfcRtuAddressread-writemandatorySet link address for a RTU in multilink mode. RTU link address can not be repeated. If address already exists, then it returns error.