MIB Viewer

TRANSMODE1100

408 objects
This is the enterprise specific MIB for Transmode
Imported Objects
SNMPv2-SMIenterprises MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDateAndTime DisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3Nodeorg
1.3.6Nodedod
1.3.6.1Nodeinternet
1.3.6.1.4Nodeprivate
1.3.6.1.4.1Nodeenterprises
1.3.6.1.4.1.11857IdentitytransmodeThis is the enterprise specific MIB for Transmode
1.3.6.1.4.1.11857.1Nodesystem1100
1.3.6.1.4.1.11857.1.1NodetrmAlarmHandling
1.3.6.1.4.1.11857.1.1.1NodetrmAlarmConfig
1.3.6.1.4.1.11857.1.1.1.1NodetrmAlarmGeneral
1.3.6.1.4.1.11857.1.1.1.1.1ScalartrmAutoAcknowledgeread-writecurrentIndicates if alarms should be automatically acknowledged or not. Can be on(1) or off(2).
1.3.6.1.4.1.11857.1.1.1.1.2ScalartrmClearAlarmLogread-writecurrentUsed to delete all history alarms. To delete all history alarms, a SetRequest-PDU with a clear(1) value encoding is used.
1.3.6.1.4.1.11857.1.1.1.1.3ScalartrmTemperatureread-writecurrentIndicates the temperature unit used in the system. Can be celsius(1) or farenheit(2).
1.3.6.1.4.1.11857.1.1.1.1.4ScalartrmAlarmTemperatureHighread-writecurrentHigh temperature level. This parameter indicates at what level a High temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenhe…
1.3.6.1.4.1.11857.1.1.1.1.5ScalartrmAlarmTemperatureHighHystread-writecurrentHigh termperature hysteresis. This parameter is used together with trmAlarmTempemperatureHigh to decide when a High temperature alarm will cease. The alarm wil…
1.3.6.1.4.1.11857.1.1.1.1.6ScalartrmAlarmTemperatureLowread-writecurrentLow temperature level. This parameter indicates at what level a Low temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit…
1.3.6.1.4.1.11857.1.1.1.1.7ScalartrmAlarmTemperatureLowHystread-writecurrentLow termperature hysteresis. This parameter is used together with trmAlarmTemperatureLow to decide when a Low temperature alarm will cease. The alarm will ceas…
1.3.6.1.4.1.11857.1.1.1.1.8ScalartrmPluginResetread-writecurrentUsed to reset all the plug in units. To reset all units, a SetRequest-PDU with a reset(1) value encoding is used.
1.3.6.1.4.1.11857.1.1.1.1.9ScalartrmOpticalInputPowerHighPINLineread-writecurrentOptical input power high alarm level for line interface PINs. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.10ScalartrmOpticalInputPowerHighAPDLineread-writecurrentOptical input power high alarm level for client interface APDs. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.11ScalartrmOpticalInputPowerLowPINLineread-writecurrentOptical input power low alarm level for client interface PINs. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.12ScalartrmOpticalInputPowerLowAPDLineread-writecurrentOptical input power low alarm level for client interface APDs. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.13ScalartrmCascaderead-writecurrentShows if Cascading is activated or not and is also used to enable/diasable Cascading. activate(1) means activated and deactivate(2) means not activated.
1.3.6.1.4.1.11857.1.1.1.1.14ScalartrmCascadeStatusread-onlycurrentDisplays the current operating mode of the Cascading. Can be deactivated[1], initializing(2), ok(3) or failure(4).
1.3.6.1.4.1.11857.1.1.1.1.15ScalartrmOpticalInputPowerHighAPDLine2read-writecurrentOptical input power high alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.16ScalartrmOpticalInputPowerLowAPDLine2read-writecurrentOptical input power low alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.17ScalartrmOpticalInputPowerHigh850Clientread-writecurrentOptical input power high alarm level for 850 nm client interface. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.18ScalartrmOpticalInputPowerHigh1310Clientread-writecurrentOptical input power high alarm level for 1310 nm client interface. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.19ScalartrmOpticalInputPowerLow850Clientread-writecurrentOptical input power low alarm level for 850 nm client interface. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.1.20ScalartrmOpticalInputPowerLow1310Clientread-writecurrentOptical input power low alarm level for 1310 nm client interface. Value displayed and set is dBm/10.
1.3.6.1.4.1.11857.1.1.1.2NodetrmAlarmSeverity
1.3.6.1.4.1.11857.1.1.1.2.1TabletrmAlarmSeverityTablenot-accessiblecurrentA list of all type of alarms in the system.
1.3.6.1.4.1.11857.1.1.1.2.1.1RowtrmAlarmSeverityEntrynot-accessiblecurrentA set of parameters that describe a alarm.
1.3.6.1.4.1.11857.1.1.1.2.1.1.1ColumntrmAlarmSeverityIdnot-accessiblecurrentAn id that uniquely identifies an alarm.
1.3.6.1.4.1.11857.1.1.1.2.1.1.2ColumntrmAlarmSeverityNameread-onlycurrentThe alarm name.
1.3.6.1.4.1.11857.1.1.1.2.1.1.3ColumntrmAlarmSeverityLevelread-writecurrentIndicates the alarm severity. Can be set to critical (1) , major (2) , minor (3) , warning (4) or off(5)
1.3.6.1.4.1.11857.1.1.1.3NodetrmAlarmExternal
1.3.6.1.4.1.11857.1.1.1.3.1TabletrmAlarmExternalTablenot-accessiblecurrentA list of all external alarms.
1.3.6.1.4.1.11857.1.1.1.3.1.1RowtrmAlarmExternalEntrynot-accessiblecurrentA set of parameters that describe a external alarm.
1.3.6.1.4.1.11857.1.1.1.3.1.1.1ColumntrmAlarmExternalIdnot-accessiblecurrentAn id that uniquely identifies an external alarm. 1 = External alarm 1, 2 = External alarm 2 and 3 = External alarm 3.
1.3.6.1.4.1.11857.1.1.1.3.1.1.2ColumntrmAlarmExternalNameread-writecurrentThe External alarm name. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.1.1.3.1.1.3ColumntrmAlarmExternalLevelread-writecurrentAlarm level that activates the alarm. Can be activelow (1) or activehigh (2).
1.3.6.1.4.1.11857.1.1.2NodetrmAlarmLog
1.3.6.1.4.1.11857.1.1.2.1TabletrmAlarmLogTablenot-accessiblecurrentA table of history alarms in the system. The number of entries are as many as there are acknowledged alarms in the system.
1.3.6.1.4.1.11857.1.1.2.1.1RowtrmAlarmLogEntrynot-accessiblecurrentA set of parameters that describe a history alarm. A row in this table can not be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.11857.1.1.2.1.1.1ColumntrmAlarmLogIndexnot-accessiblecurrentThe index for this alarm entry.
1.3.6.1.4.1.11857.1.1.2.1.1.2ColumntrmAlarmLogRackNumberread-onlycurrentThe rack number where the alarm occured.
1.3.6.1.4.1.11857.1.1.2.1.1.3ColumntrmAlarmLogSlotNumberread-onlycurrentThe slot number where the alarm occured.
1.3.6.1.4.1.11857.1.1.2.1.1.4ColumntrmAlarmLogNameread-onlycurrentThe alarm description.
1.3.6.1.4.1.11857.1.1.2.1.1.5ColumntrmAlarmLogSeverityread-onlycurrentThe alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4).
1.3.6.1.4.1.11857.1.1.2.1.1.6ColumntrmAlarmLogUnitread-onlycurrentThe type, version and index for the unit associated with the alarm.
1.3.6.1.4.1.11857.1.1.2.1.1.7ColumntrmAlarmLogSerialNumberread-onlycurrentThe serial number for the unit associated with the alarm.
1.3.6.1.4.1.11857.1.1.2.1.1.8ColumntrmAlarmLogActTimeread-onlycurrentThe time the alarm was generated.
1.3.6.1.4.1.11857.1.1.2.1.1.9ColumntrmAlarmLogDeactTimeread-onlycurrentThe time the alarm was deactivated.
1.3.6.1.4.1.11857.1.1.2.1.1.10ColumntrmAlarmLogAckTimeread-onlycurrentThis time the alarm was acknowledged.
1.3.6.1.4.1.11857.1.1.2.1.1.11ColumntrmAlarmLogAckUserread-onlycurrentThe user that acknowledged the alarm.
1.3.6.1.4.1.11857.1.1.3NodetrmAlarmActive
1.3.6.1.4.1.11857.1.1.3.1NodetrmAlarmActiveGeneral
1.3.6.1.4.1.11857.1.1.3.1.1ScalartrmAlarmActiveCounterread-onlycurrentIndicates the total number of active alarms in the system.
1.3.6.1.4.1.11857.1.1.3.1.2ScalartrmAlarmActiveAcknowledgeAllDeactread-writecurrentAcknowledges all alarm that is not acknowledged and is deactivated. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used.
1.3.6.1.4.1.11857.1.1.3.1.3ScalartrmAlarmActiveAcknowledgeAllread-writecurrentAcknowledgedges all alarms that is not acknowledged. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used.
1.3.6.1.4.1.11857.1.1.3.2TabletrmAlarmActiveTablenot-accessiblecurrentA table of active alarms in the system. With active alarm the meaning is a not acknowledged alarm. The number of entries are as many as there are not acknowled…
1.3.6.1.4.1.11857.1.1.3.2.1RowtrmAlarmActiveEntrynot-accessiblecurrentAn entry in the table of active alarms in the system. A row in this table can not be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.11857.1.1.3.2.1.1ColumntrmAlarmActiveIndexnot-accessiblecurrentThe index for this alarm entry.
1.3.6.1.4.1.11857.1.1.3.2.1.2ColumntrmAlarmActiveRackNumberread-onlycurrentThe rack number where the alarm occured.
1.3.6.1.4.1.11857.1.1.3.2.1.3ColumntrmAlarmActiveSlotNumberread-onlycurrentThe slot number where the alarm occured.
1.3.6.1.4.1.11857.1.1.3.2.1.4ColumntrmAlarmActiveNameread-onlycurrentThe alarm description
1.3.6.1.4.1.11857.1.1.3.2.1.5ColumntrmAlarmActiveSeverityread-onlycurrentThe alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4).
1.3.6.1.4.1.11857.1.1.3.2.1.6ColumntrmAlarmActiveUnitread-onlycurrentThe type, version and index of the unit associated with the alarm.
1.3.6.1.4.1.11857.1.1.3.2.1.7ColumntrmAlarmActiveSerialNumberread-onlycurrentThe serial number of the unit associated with the alarm.
1.3.6.1.4.1.11857.1.1.3.2.1.8ColumntrmAlarmActiveActTimeread-onlycurrentThe time the alarm was generated.
1.3.6.1.4.1.11857.1.1.3.2.1.9ColumntrmAlarmActiveDeactTimeread-onlycurrentThe time the alarm was deactivated.
1.3.6.1.4.1.11857.1.1.3.2.1.10ColumntrmAlarmActiveAcknowledgeread-writecurrentThis oid is used to acknowledge a alarm. To acknowledge a alarm, a SetRequest-PDU with a acknowledge(1) value encoding is used.
1.3.6.1.4.1.11857.1.2NodetrmSubrack
1.3.6.1.4.1.11857.1.2.1NodetrmSubrackList
1.3.6.1.4.1.11857.1.2.1.1TabletrmSubrackListTablenot-accessiblecurrentA list of units present in the subrack(s).
1.3.6.1.4.1.11857.1.2.1.1.1RowtrmSubrackListEntrynot-accessiblecurrentA set of parameters that describe a unit.
1.3.6.1.4.1.11857.1.2.1.1.1.1ColumntrmListRackNumbernot-accessiblecurrentThis object indicates in what rack the unit is situated in.
1.3.6.1.4.1.11857.1.2.1.1.1.2ColumntrmListSlotNumbernot-accessiblecurrentThis object indicates in what slot the unit is situated in. Can be slot 1-12.
1.3.6.1.4.1.11857.1.2.1.1.1.3ColumntrmListUnitPresentread-onlycurrentThis object indicates if the unit is present yes(1) or not no(2).
1.3.6.1.4.1.11857.1.2.1.1.1.4ColumntrmListProductNumberread-onlycurrentThe Product number of the unit (XXYY/ZZ) where: Board type = XX Board version = YY Board index = ZZ.
1.3.6.1.4.1.11857.1.2.1.1.1.5ColumntrmListProductDescriptionread-onlycurrentA product description of the unit.
1.3.6.1.4.1.11857.1.2.1.1.1.6ColumntrmListHwRevisionread-onlycurrentThe hardware revision of the unit.
1.3.6.1.4.1.11857.1.2.1.1.1.7ColumntrmListSerialNumberread-onlycurrentThe serial number of the unit.
1.3.6.1.4.1.11857.1.2.1.1.1.8ColumntrmListManufacturingDateread-onlycurrentThe manufacturing date of the unit. Format is Year:Week.
1.3.6.1.4.1.11857.1.2.1.1.1.9ColumntrmListSoftwareProdNoread-onlycurrentThe software product number of the software on this unit.
1.3.6.1.4.1.11857.1.2.1.1.1.10ColumntrmListSwVersionread-onlycurrentRevision number of the software on this unit.
1.3.6.1.4.1.11857.1.2.2NodetrmSubrackUnits
1.3.6.1.4.1.11857.1.2.2.1Nodetrm6001
1.3.6.1.4.1.11857.1.2.2.1.1Nodetrm6001PM
1.3.6.1.4.1.11857.1.2.2.1.1.1Tabletrm6001Tablenot-accessiblecurrentList of NMB(s).
1.3.6.1.4.1.11857.1.2.2.1.1.1.1Rowtrm6001Entrynot-accessiblecurrentA set of parameters that describes an NMB
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.1Columntrm6001RackNumbernot-accessiblecurrentThe network management board rack number.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.2Columntrm6001SlotNumbernot-accessiblecurrentThe network management board slot number.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.3Columntrm6001IPAddressread-onlycurrentThe network management board IP address.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.4Columntrm6001MACAddressread-onlycurrentThe network management board MAC address.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.5Columntrm6001Temperatureread-onlycurrentThe network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.6Columntrm6001UpTimeread-onlycurrentThe network management board up time.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.7Columntrm6001Dateread-writecurrentUsed to set the NMB date on format YYYY-MM-DD.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.8Columntrm6001Timeread-writecurrentUsed to set the NMB time on format HH:MM:SS.
1.3.6.1.4.1.11857.1.2.2.1.1.1.1.9Columntrm6001SwResetread-writecurrentUsed to reset the NMB unit. To reset the NMB unit, a SetRequest-PDU with a reset(1) value encoding is used.
1.3.6.1.4.1.11857.1.2.2.1.2Nodetrm6001FM
1.3.6.1.4.1.11857.1.2.2.1.2.0Nodetrm6001Traps
1.3.6.1.4.1.11857.1.2.2.1.2.0.1Notificationtrm6001TrapExternal1currentThis trap is sent when a External 1 alarm is generated at the NMB 6001 unit.
1.3.6.1.4.1.11857.1.2.2.1.2.0.2Notificationtrm6001TrapExternal2currentThis trap is sent when a External 2 alarm is generated at the NMB 6001 unit.
1.3.6.1.4.1.11857.1.2.2.1.2.0.3Notificationtrm6001TrapExternal3currentThis trap is sent when a External 3 alarm is generated at the NMB 6001 unit.
1.3.6.1.4.1.11857.1.2.2.1.2.0.4Notificationtrm6001CascadeFailurecurrentThis trap is sent when a attempt to enable Cascading has failed or connection is lost with the cascading rack.
1.3.6.1.4.1.11857.1.2.2.2Nodetrm9xxx
1.3.6.1.4.1.11857.1.2.2.2.1Nodetrm9xxxPM
1.3.6.1.4.1.11857.1.2.2.2.1.1Tabletrm9xxxTablenot-accessiblecurrentA list of power supply units in the subrack(s).
1.3.6.1.4.1.11857.1.2.2.2.1.1.1Rowtrm9xxxEntrynot-accessiblecurrentA set of parameters that describe a power supply unit.
1.3.6.1.4.1.11857.1.2.2.2.1.1.1.1Columntrm9xxxRackNumbernot-accessiblecurrentThis object indicates in what rack the power supply is situated in.
1.3.6.1.4.1.11857.1.2.2.2.1.1.1.2Columntrm9xxxSlotNumbernot-accessiblecurrentThis object indicates in what slot number the power supply is situated in. Can be slot 10 or 11.
1.3.6.1.4.1.11857.1.2.2.2.1.1.1.3Columntrm9xxxPresentread-onlycurrentThis parameter indicates if the power supply is present or not. yes(1) means present and no(2) means not present.
1.3.6.1.4.1.11857.1.2.2.2.1.1.1.4Columntrm9xxxTyperead-onlycurrentThis parameter describes what kind of power supply this unit is. Power9048(2) means a power supply with input pover 48 VDC, Power9220(3) means 100-240 VAC. If …
1.3.6.1.4.1.11857.1.2.2.2.1.1.1.5Columntrm9xxxStatusread-onlycurrentThis parameter indicates the status of the power supply. off(1) means that the power supply not is operating and on(2) means that it is operating.
1.3.6.1.4.1.11857.1.2.2.2.2Nodetrm9xxxFM
1.3.6.1.4.1.11857.1.2.2.2.2.0Nodetrm9xxxTraps
1.3.6.1.4.1.11857.1.2.2.2.2.0.1Notificationtrm9xxxTrapFailurecurrentThis trap indicates that a fault was detected on a power supply or the input power is removed.
1.3.6.1.4.1.11857.1.2.2.2.2.0.2Notificationtrm9xxxTrapMissingcurrentThis trap is sent when a power supply is missing.
1.3.6.1.4.1.11857.1.2.2.3Nodetrm75xx
1.3.6.1.4.1.11857.1.2.2.3.1Nodetrm75xxPM
1.3.6.1.4.1.11857.1.2.2.3.1.1Tabletrm75xxTablenot-accessiblecurrentA list of 70 & 75 units in the subrack(s).
1.3.6.1.4.1.11857.1.2.2.3.1.1.1Rowtrm75xxEntrynot-accessiblecurrentA set of parameters that describe a 70 or a 75 unit.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.1Columntrm75xxRackNumbernot-accessiblecurrentThis parameter indicates in what rack the unit is situated in.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.2Columntrm75xxSlotNumbernot-accessiblecurrentThis parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.3Columntrm75xxRxLineread-onlycurrentThis parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or No…
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.4Columntrm75xxEstProtLineread-onlycurrentThis parameter indicates the Estimated Protocol for the line interface input.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.5Columntrm75xxEstFibRateLineread-onlycurrentThis parameter indicates the Estimated Fiber Rate for the line interface input in Mbit/s.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.6Columntrm75xxTxLineread-onlycurrentThis parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.7Columntrm75xxTxModeread-writecurrentThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when re…
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.8Columntrm75xxWavelengthLineread-onlycurrentThis parameter indicates the nominal wavelength for the line interface transiever.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.9Columntrm75xxRxClientread-onlycurrentThis parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or …
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.10Columntrm75xxEstProtClientread-onlycurrentThis parameter indicates the Estimated Protocol for the client interface input.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.11Columntrm75xxEstFibRateClientread-onlycurrentThis parameter indicates the Estimated Fiber Rate for the client interface input in Mbit/s.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.12Columntrm75xxTxClientread-onlycurrentThis parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or …
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.13Columntrm75xxTxModeClientread-onlyobsoleteThis object is obsolete and not used anymore.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.14Columntrm75xxIDStringClientread-writecurrentThis parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.15Columntrm75xxIPAddressClientread-writecurrentThis parameter indentifies the equipment(IP Address) connected to the client interface.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.16Columntrm75xxWavelengthClientread-onlycurrentThis parameter indicates the nominal wavelength for the client interface transiever.
1.3.6.1.4.1.11857.1.2.2.3.1.1.1.17Columntrm75xxSpeedLimitread-writecurrentThis parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the C…
1.3.6.1.4.1.11857.1.2.2.3.2Nodetrm75xxFM
1.3.6.1.4.1.11857.1.2.2.3.2.0Nodetrm75xxTraps
1.3.6.1.4.1.11857.1.2.2.3.2.0.1Notificationtrm75xxTrapGlitchLinecurrentThis trap is sent when a unit experiences a split second optical input power glitch at the line interface.
1.3.6.1.4.1.11857.1.2.2.3.2.0.2Notificationtrm75xxTrapLopLinecurrentThis trap is sent when the optical input power is lost at the line interface.
1.3.6.1.4.1.11857.1.2.2.3.2.0.3Notificationtrm75xxTrapTxLinecurrentThis trap is sent when a unit fails to generate optical output power at Tx line interface.
1.3.6.1.4.1.11857.1.2.2.3.2.0.4Notificationtrm75xxTrapTxDisableLinecurrentThis trap is sent when the optical output power for the line interface is disabled.
1.3.6.1.4.1.11857.1.2.2.3.2.0.5Notificationtrm75xxTrapGlitchClientcurrentThis trap is sent when a unit experiences a split second optical input power glitch at the client interface.
1.3.6.1.4.1.11857.1.2.2.3.2.0.6Notificationtrm75xxTrapLopClientcurrentThis trap is sent when the optical input power is lost at the client interface.
1.3.6.1.4.1.11857.1.2.2.3.2.0.7Notificationtrm75xxTrapTxClientcurrentThis trap is sent when a unit fails to generate optical output power at Tx client.
1.3.6.1.4.1.11857.1.2.2.3.2.0.8Notificationtrm75xxTrapTxDisableClientcurrentThis trap is sent when the optical output power for the client interface is disabled.
1.3.6.1.4.1.11857.1.2.2.4Nodetrm76xx
1.3.6.1.4.1.11857.1.2.2.4.1Nodetrm76xxPM
1.3.6.1.4.1.11857.1.2.2.4.1.1Tabletrm76xxTablenot-accessiblecurrentA list of 76YY/ZZ in the subrack(s).
1.3.6.1.4.1.11857.1.2.2.4.1.1.1Rowtrm76xxEntrynot-accessiblecurrentA set of parameters that describe the Subrack units
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.1Columntrm76xxRackNumbernot-accessiblecurrentThis parameter indicates in what rack the unit is situated in.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.2Columntrm76xxSlotNumbernot-accessiblecurrentThis parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.3Columntrm76xxTemperatureread-onlycurrentThis parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.4Columntrm76xxCDRread-writecurrentThis parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.5Columntrm76xxCustomFibRateread-writecurrentThis parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.6Columntrm76xxTxModeread-writecurrentThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical o…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.7Columntrm76xxLineLoopModeread-writecurrentThis parameter is used to set the line loop mode. Can be set to normal(1) or looptest(2). normal(1): The line loop test function is off. looptest(2): Line is l…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.8Columntrm76xxSwResetread-writecurrentUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.9Columntrm76xxRxLineread-onlycurrentThis parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or No…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.10Columntrm76xxOpticalInPowLineread-onlycurrentThis parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.11Columntrm76xxSpeedLimitread-writecurrentThis parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the C…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.12Columntrm76xxEstProtLineread-onlycurrentThis parameter indicates the Estimated Protocol for the line interface Rx.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.13Columntrm76xxEstFibRateLineread-onlycurrentThis parameter indicates the Estimated Fiber Rate for the line interface Rx in Mbit/s.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.14Columntrm76xxTxLineread-onlycurrentThis parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.15Columntrm76xxOpticalOutPowLineread-onlycurrentThis parameter indicates the optical output power for the line interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -10…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.16Columntrm76xxProdOutPowLineread-onlycurrentThis parameter indicates the production output power for the line interface. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 …
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.17Columntrm76xxLaserBiasCurLineread-onlycurrentThis parameter indicates the laser bias current for the line interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Di…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.18Columntrm76xxProdLaserBiasCurLineread-onlycurrentThis parameter indicates the production laser bias current for the line interface. Divide this value by 10 to show the laser bias current in mA.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.19Columntrm76xxWavelengthLineread-onlycurrentThis parameter indicates the nominal wavelength for the line interface transiever.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.20Columntrm76xxRxClientread-onlycurrentThis parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or …
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.21Columntrm76xxEstProtClientread-onlycurrentThis parameter indicates the Estimated Protocol for the client interface Rx.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.22Columntrm76xxEstFibRateClientread-onlycurrentThis parameter indicates the Estimated Fiber Rate for the client interface Rx in Mbit/s.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.23Columntrm76xxTxClientread-onlycurrentThis parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or …
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.24Columntrm76xxIDStringClientread-writecurrentThis parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.25Columntrm76xxIPAddressClientread-writecurrentThis parameter indentifies the equipment(IP Address) connected to the client interface.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.26Columntrm76xxWavelengthClientread-onlycurrentThis parameter indicates the nominal wavelength for the client interface transiever.
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.27Columntrm76xxOpticalInPowClientread-onlycurrentThis parameter indicates the Optical input power for the client interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). …
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.28Columntrm76xxOpticalOutPowClientread-onlycurrentThis parameter indicates the optical output power for the client interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -…
1.3.6.1.4.1.11857.1.2.2.4.1.1.1.29Columntrm76xxLaserBiasCurClientread-onlycurrentThis parameter indicates the laser bias current for the client interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. …
1.3.6.1.4.1.11857.1.2.2.4.2Nodetrm76xxFM
1.3.6.1.4.1.11857.1.2.2.4.2.0Nodetrm76xxTraps
1.3.6.1.4.1.11857.1.2.2.4.2.0.1Notificationtrm76xxTrapCDRAutoModeRangeChangeLinecurrentThis trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used con…
1.3.6.1.4.1.11857.1.2.2.4.2.0.2Notificationtrm76xxTrapRxGlitchLinecurrentThis trap is sent when a unit experiences a split second optical input power glitch at the line interface.
1.3.6.1.4.1.11857.1.2.2.4.2.0.3Notificationtrm76xxTrapLopLinecurrentThis trap is sent when the optical input power is lost at the line interface.
1.3.6.1.4.1.11857.1.2.2.4.2.0.4Notificationtrm76xxTrapRxHighPowerLinecurrentThis trap is sent when the optical input power for line is higher than trmOpticalInputPowerHighPINLine or trmOpticalInputPowerHighAPDLine.
1.3.6.1.4.1.11857.1.2.2.4.2.0.5Notificationtrm76xxTrapRxLowPowerLinecurrentThis trap is sent when the optical input power for line is lower than trmOpticalInputPowerLowPINLine or trmOpticalInputPowerLowAPDLine.
1.3.6.1.4.1.11857.1.2.2.4.2.0.6Notificationtrm76xxTrapLoLLinecurrentThis trap is sent when the line Tx indicates loss of 3R synchronization.
1.3.6.1.4.1.11857.1.2.2.4.2.0.7Notificationtrm76xxTrapTxLinecurrentThis trap is sent when a unit fails to generate optical output power at Tx line.
1.3.6.1.4.1.11857.1.2.2.4.2.0.8Notificationtrm76xxTrapSFPFailureLineobsoleteThis trap/alarm is not used in the system and is obsolete.
1.3.6.1.4.1.11857.1.2.2.4.2.0.9Notificationtrm76xxTrapSFPMissingLineobsoleteThis trap/alarm is not used in the system and is obsolete.
1.3.6.1.4.1.11857.1.2.2.4.2.0.10Notificationtrm76xxTrapCDRAutoModeRangeChangeClientcurrentThis trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used con…
1.3.6.1.4.1.11857.1.2.2.4.2.0.11Notificationtrm76xxTrapRxGlitchClientcurrentThis trap is sent when a unit experiences a split second optical input power glitch at the client interface.
1.3.6.1.4.1.11857.1.2.2.4.2.0.12Notificationtrm76xxTrapLopClientcurrentThis trap is sent when the optical input power is lost at the client interface.
1.3.6.1.4.1.11857.1.2.2.4.2.0.13Notificationtrm76xxTrapRxHighPowerClientobsoleteThis trap/alarm is not used in the system and the object is obsolete.
1.3.6.1.4.1.11857.1.2.2.4.2.0.14Notificationtrm76xxTrapRxLowPowerClientobsoleteThis trap/alarm is not used in the system and the object is obsolete.
1.3.6.1.4.1.11857.1.2.2.4.2.0.15Notificationtrm76xxTrapLoLClientcurrentThis trap is sent when the client Tx indicates loss of 3R synchronization.
1.3.6.1.4.1.11857.1.2.2.4.2.0.16Notificationtrm76xxTrapTxClientcurrentThis trap is sent when a unit fails to generate optical output power at Tx client.
1.3.6.1.4.1.11857.1.2.2.4.2.0.17Notificationtrm76xxTrapSFPFailureClientcurrentThis trap is sent when a unit have a client SFP transiever got a failure or a Bias temperature alarm.
1.3.6.1.4.1.11857.1.2.2.4.2.0.18Notificationtrm76xxTrapSFPMissingClientcurrentThis trap is sent when a unit doesn't have a client SFP transiever.
1.3.6.1.4.1.11857.1.2.2.4.2.0.19Notificationtrm76xxTrapTxDisablecurrentThis trap is sent when the optical output power for both the line and client interface have been disabled.
1.3.6.1.4.1.11857.1.2.2.4.2.0.20Notificationtrm76xxTrapLaserDegradationLinecurrentThis trap is sent when there is a laser degradation on the line laser. This means that the laser bias current is raised to be able to keep the optical output f…
1.3.6.1.4.1.11857.1.2.2.4.2.0.21Notificationtrm76xxTrapEyeQualityLinecurrentFor future use.
1.3.6.1.4.1.11857.1.2.2.4.2.0.22Notificationtrm76xxTrapEyeQualityClientcurrentFor future use.
1.3.6.1.4.1.11857.1.2.2.5Nodetrm803x
1.3.6.1.4.1.11857.1.2.2.5.1Nodetrm803xPM
1.3.6.1.4.1.11857.1.2.2.5.1.1Tabletrm803xTablenot-accessiblecurrentA list of 803x units.
1.3.6.1.4.1.11857.1.2.2.5.1.1.1Rowtrm803xEntrynot-accessiblecurrentA set of parameters that describe a 803x unit.
1.3.6.1.4.1.11857.1.2.2.5.1.1.1.1Columntrm803xRackNumbernot-accessiblecurrentThis object indicates in what rack the 803x unit is situated in.
1.3.6.1.4.1.11857.1.2.2.5.1.1.1.2Columntrm803xSlotNumbernot-accessiblecurrentThis object indicates in what slot number the 803x unitis situated in. Can only be slot 12.
1.3.6.1.4.1.11857.1.2.2.5.1.1.1.3Columntrm803xMuxTyperead-onlycurrentThis parameter indicates what Mux type this is. Can be none(1), mux8030(2), mux8031(3), mux8032(4), mux8033(5) or mux8034(6).
1.3.6.1.4.1.11857.1.2.2.5.1.1.1.4Columntrm803xIDStringLineread-writecurrentThis parameter identifies the equipment connected to the line interface. The ID string can be used to indentify a fiber pair/link. Maximum number of characters…
1.3.6.1.4.1.11857.1.2.2.5.1.1.1.5Columntrm803xIPAddressLineread-writecurrentThis parameter identifies the equipment connected to the line interface. The IP address can be used to indentify the corresponding NMB unit.
1.3.6.1.4.1.11857.1.2.2.6Nodetrm2204
1.3.6.1.4.1.11857.1.2.2.6.1Nodetrm2204PM
1.3.6.1.4.1.11857.1.2.2.6.1.1Tabletrm2204Tablenot-accessiblecurrentA list of 2204 units.
1.3.6.1.4.1.11857.1.2.2.6.1.1.1Rowtrm2204Entrynot-accessiblecurrentA set of parameters that describe a 2204 unit.
1.3.6.1.4.1.11857.1.2.2.6.1.1.1.1Columntrm2204RackNumbernot-accessiblecurrentThis object indicates in what rack the 2204 unit is situated in.
1.3.6.1.4.1.11857.1.2.2.6.1.1.1.2Columntrm2204SlotNumbernot-accessiblecurrentThis object indicates in what slot number the 2204 unitis situated in. Can be slot 1-8.
1.3.6.1.4.1.11857.1.2.2.6.1.1.1.3Columntrm2204SecurityModeread-writecurrentThis parameter indicates the security mode for the unit. It is also used to set the Security Mode for the unit. Can be activated(1) or deactivated(2).
1.3.6.1.4.1.11857.1.2.2.7Nodetrm26xx
1.3.6.1.4.1.11857.1.2.2.7.1Nodetrm26xxPM
1.3.6.1.4.1.11857.1.2.2.7.1.1Tabletrm26xxTablenot-accessiblecurrentA list of 26xx units in the subrack(s).
1.3.6.1.4.1.11857.1.2.2.7.1.1.1Rowtrm26xxEntrynot-accessiblecurrentA set of parameters that describe a 26xx unit.
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.1Columntrm26xxRackNumbernot-accessiblecurrentThis parameter indicates in what rack the unit is situated in.
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.2Columntrm26xxSlotNumbernot-accessiblecurrentThis parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8.
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.3Columntrm26xxStatusread-onlycurrentThis parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or No…
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.4Columntrm26xxTemperatureread-onlycurrentThe network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used.
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.5Columntrm26xxTxModeread-writecurrentThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when re…
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.6Columntrm26xxSwResetread-writecurrentUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.7Columntrm26xxOpticalPowerPIN1read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.8Columntrm26xxOpticalPowerPIN2read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.9Columntrm26xxLogOpticalPowerread-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.10Columntrm26xxTemperatureTEC1read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.11Columntrm26xxTemperatureTEC2read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.12Columntrm26xxVoltageTEC1read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.13Columntrm26xxVoltageTEC2read-onlyobsolete
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.14Columntrm26xxCurrentTEC1read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.15Columntrm26xxCurrentTEC2read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.16Columntrm26xxCurrentBIAS1read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.17Columntrm26xxCurrentBIAS2read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.18Columntrm26xxVoltageBIAS1read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.1.1.1.19Columntrm26xxVoltageBIAS2read-onlycurrent
1.3.6.1.4.1.11857.1.2.2.7.2Nodetrm26xxFM
1.3.6.1.4.1.11857.1.2.2.7.2.0Nodetrm26xxTraps
1.3.6.1.4.1.11857.1.2.2.7.2.0.1Notificationtrm26xxTrapTEC1Faultycurrent
1.3.6.1.4.1.11857.1.2.2.7.2.0.2Notificationtrm26xxTrapTEC2Faultycurrent
1.3.6.1.4.1.11857.1.2.2.7.2.0.3Notificationtrm26xxTrapBIAS1Faultycurrent
1.3.6.1.4.1.11857.1.2.2.7.2.0.4Notificationtrm26xxTrapBIAS2Faultycurrent
1.3.6.1.4.1.11857.1.2.2.7.2.0.5Notificationtrm26xxTrapPIUTempShutdowncurrent
1.3.6.1.4.1.11857.1.2.2.7.2.0.6Notificationtrm26xxTrapOpticalLinkdowncurrent
1.3.6.1.4.1.11857.1.2.2.7.2.0.7Notificationtrm26xxTrapTxDisablecurrentThis trap is sent when the amplifier has been disabled.
1.3.6.1.4.1.11857.1.2.2.8Nodetrm25xx
1.3.6.1.4.1.11857.1.2.2.8.1Nodetrm25xxPM
1.3.6.1.4.1.11857.1.2.2.8.1.1Tabletrm25xxTablenot-accessiblecurrentA list of 25xx in the subrack(s).
1.3.6.1.4.1.11857.1.2.2.8.1.1.1Rowtrm25xxEntrynot-accessiblecurrentA set of parameters that describe the Subrack units
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.1Columntrm25xxRackNumbernot-accessiblecurrentThis parameter indicates in what rack the unit is situated in.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.2Columntrm25xxSlotNumbernot-accessiblecurrentThis parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.3Columntrm25xxWorkingLineStatusread-onlycurrentThis parameter indicates the Working Line status.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.4Columntrm25xxProtectingLineStatusread-onlycurrentThis parameter indicates the Protecting Line status.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.5Columntrm25xxTemperatureread-onlycurrentThis parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.6Columntrm25xxSwResetread-writecurrentUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.7Columntrm25xxRxLineread-onlycurrentThis parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not …
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.8Columntrm25xxOpticalInPowLineread-onlycurrentThis parameter indicates the Optical input power for the line Subrack. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If t…
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.9Columntrm25xxSpeedLimitread-writecurrentThis parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the C…
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.10Columntrm25xxEstProtLineread-onlycurrentThis parameter indicates the Estimated Protocol for the line Subrack input.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.11Columntrm25xxEstFibRateLineread-onlycurrentThis parameter indicates the Estimated Fiber Rate for the line Subrack input in Mbit/s.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.12Columntrm25xxTxLineread-onlycurrentThis parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.13Columntrm25xxOpticalOutPowLineread-onlycurrentThis parameter indicates the optical output power for the line Subrack. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 …
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.14Columntrm25xxProdOutPowLineread-onlycurrentThis parameter indicates the production output power for the line Subrack. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to…
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.15Columntrm25xxLaserBiasCurLineread-onlycurrentThis parameter indicates the laser bias current for the line Subrack. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divi…
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.16Columntrm25xxProdLaserBiasCurLineread-onlycurrentThis parameter indicates the production laser bias current for the line Subrack. Divide this value by 10 to show the laser bias current in mA.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.17Columntrm25xxCDRread-writecurrentThis parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video…
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.18Columntrm25xxCustomFibRateread-writecurrentThis parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s.
1.3.6.1.4.1.11857.1.2.2.8.1.1.1.19Columntrm25xxTxModeread-writecurrentThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical o…
1.3.6.1.4.1.11857.1.2.2.8.2Nodetrm25xxFM
1.3.6.1.4.1.11857.1.2.2.8.2.0Nodetrm25xxTraps
1.3.6.1.4.1.11857.1.2.2.8.2.0.1Notificationtrm25xxTrapWorkingLineFailurecurrentThis trap is sent when the Working Line goes down.
1.3.6.1.4.1.11857.1.2.2.8.2.0.2Notificationtrm25xxTrapProtectingLineFailurecurrentThis trap is sent when the Protecting Line goes down.
1.3.6.1.4.1.11857.1.2.2.8.2.0.3Notificationtrm25xxTrapWorkingAndProtectingLineFailurecurrentThis trap is sent when both the Working and Protecting Line goes down.
1.3.6.1.4.1.11857.1.2.2.9Nodetrm53005500
1.3.6.1.4.1.11857.1.2.2.9.1Nodetrm53005500PM
1.3.6.1.4.1.11857.1.2.2.9.1.1Tabletrm53005500Tablenot-accessiblecurrentA list of all 5300/01 and 5500/01 units in the subrack(s).
1.3.6.1.4.1.11857.1.2.2.9.1.1.1Rowtrm53005500Entrynot-accessiblecurrentA set of parameters that describe a 5300/01 or 5500/01 unit.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.1Columntrm53005500RackNumbernot-accessiblecurrentThis parameter indicates in what rack the unit is situated in.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.2Columntrm53005500SlotNumbernot-accessiblecurrentThis parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.3Columntrm53005500Temperatureread-onlycurrentThis parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.4Columntrm53005500SwResetread-writecurrentUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.5Columntrm53005500WavelengthLineread-onlycurrentThis parameter indicates the nominal wavelength for the line interface transiever.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.6Columntrm53005500RxLineread-onlycurrentThis parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not …
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.7Columntrm53005500OpticalInPowLineread-onlycurrentThis parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.8Columntrm53005500TxLineread-onlycurrentThis parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.9Columntrm53005500TxModeLineread-writecurrentThis parameter indicates the mode of the optical transmitter for line TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving sig…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.10Columntrm53005500WavelengthClient1read-onlycurrentThis parameter indicates the nominal wavelength for the client 1 interface transiever.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.11Columntrm53005500RxClient1read-onlycurrentThis parameter indicates the status of the optical input for the client 1 interface. It corresponds to the client 1 Rx LED status of the unit. Can be Receiving…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.12Columntrm53005500CDRClient1read-writecurrentThis parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1),…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.13Columntrm53005500TxClient1read-onlycurrentThis parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.14Columntrm53005500TxModeClient1read-writecurrentThis parameter indicates the mode of the optical transmitter for client 1 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output w…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.15Columntrm53005500IDStringClient1read-writecurrentThis parameter identifies the equipment(ID String) connected to the client 1 interface. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.16Columntrm53005500IPAddressClient1read-writecurrentThis parameter indentifies the equipment(IP Address) connected to the client 1 interface.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.17Columntrm53005500WavelengthClient2read-onlycurrentThis parameter indicates the nominal wavelength for the client 2 interface transiever.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.18Columntrm53005500RxClient2read-onlycurrentThis parameter indicates the status of the optical input for the client 2 interface. It corresponds to the client 2 Rx LED status of the unit. Can be Receiving…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.19Columntrm53005500CDRClient2read-writecurrentThis parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1),…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.20Columntrm53005500TxClient2read-onlycurrentThis parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.21Columntrm53005500TxModeClient2read-writecurrentThis parameter indicates the mode of the optical transmitter for client 2 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output w…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.22Columntrm53005500IDStringClient2read-writecurrentThis parameter identifies the equipment(ID String) connected to the client 2 interface. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.23Columntrm53005500IPAddressClient2read-writecurrentThis parameter indentifies the equipment(IP Address) connected to the client 2 interface.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.24Columntrm53005500WavelengthClient3read-onlycurrentThis parameter indicates the nominal wavelength for the client 3 interface transiever.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.25Columntrm53005500RxClient3read-onlycurrentThis parameter indicates the status of the optical input for the client 3 interface. It corresponds to the client 3 Rx LED status of the unit. Can be Receiving…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.26Columntrm53005500CDRClient3read-writecurrentThis parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1),…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.27Columntrm53005500TxClient3read-onlycurrentThis parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.28Columntrm53005500TxModeClient3read-writecurrentThis parameter indicates the mode of the optical transmitter for client 3 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output w…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.29Columntrm53005500IDStringClient3read-writecurrentThis parameter identifies the equipment(ID String) connected to the client 3 interface. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.30Columntrm53005500IPAddressClient3read-writecurrentThis parameter indentifies the equipment(IP Address) connected to the client 3 interface.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.31Columntrm53005500WavelengthClient4read-onlycurrentThis parameter indicates the nominal wavelength for the client 4 interface transiever.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.32Columntrm53005500RxClient4read-onlycurrentThis parameter indicates the status of the optical input for the client 4 interface. It corresponds to the client 4 Rx LED status of the unit. Can be Receiving…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.33Columntrm53005500CDRClient4read-writecurrentThis parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1),…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.34Columntrm53005500TxClient4read-onlycurrentThis parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.35Columntrm53005500TxModeClient4read-writecurrentThis parameter indicates the mode of the optical transmitter for client 4 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output w…
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.36Columntrm53005500IDStringClient4read-writecurrentThis parameter identifies the equipment(ID String) connected to the client 4 interface. Maximum number of characters is 20.
1.3.6.1.4.1.11857.1.2.2.9.1.1.1.37Columntrm53005500IPAddressClient4read-writecurrentThis parameter indentifies the equipment(IP Address) connected to the client 4 interface.
1.3.6.1.4.1.11857.1.2.2.9.2Nodetrm53005500FM
1.3.6.1.4.1.11857.1.2.2.9.2.0Nodetrm53005500Traps
1.3.6.1.4.1.11857.1.2.2.9.2.0.1Notificationtrm53005500TrapRxLinkdownLinecurrentThis trap is sent when the Line Rx signal is out of sync or has been lost.
1.3.6.1.4.1.11857.1.2.2.9.2.0.2Notificationtrm53005500TrapExternalsyncFailureLinecurrentThis trap is sent when the Line external sync signal is lost or is out of sync.
1.3.6.1.4.1.11857.1.2.2.9.2.0.3Notificationtrm53005500TrapSfpMissingLinecurrentThis trap is sent when the Line SFP transiever not is mounted.
1.3.6.1.4.1.11857.1.2.2.9.2.0.4Notificationtrm53005500TrapSfpBadTypeLinecurrentThis trap is sent when a invalid Line SFP is used.
1.3.6.1.4.1.11857.1.2.2.9.2.0.5Notificationtrm53005500TrapSfpFaultyLinecurrentThis trap is sent when the Line SFP is faulty.
1.3.6.1.4.1.11857.1.2.2.9.2.0.6Notificationtrm53005500TrapRxGlitchLinecurrentThis trap is sent when a unit experiences a split second optical input power glitch at the Line interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.7Notificationtrm53005500TrapTxGlitchLinecurrentThis trap is sent when a unit experiences a split second optical transmission glitch at the Line interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.8Notificationtrm53005500TrapTxDisabledLinecurrentThis trap is sent when the optical output power for the line interface have been disabled.
1.3.6.1.4.1.11857.1.2.2.9.2.0.9Notificationtrm53005500TrapRxLinkDownClient1currentThis trap is sent when the Client 1 Rx signal is out of sync or has been lost.
1.3.6.1.4.1.11857.1.2.2.9.2.0.10Notificationtrm53005500TrapTxOutOfSyncClient1currentThis trap is sent when the Client 1 tx output signal is outside the selected frequencey range.
1.3.6.1.4.1.11857.1.2.2.9.2.0.11Notificationtrm53005500TrapSfpMissingClient1currentThis trap is sent when the Client 1 SFP transiever not is mounted.
1.3.6.1.4.1.11857.1.2.2.9.2.0.12Notificationtrm53005500TrapSfpBadTypeClient1currentThis trap is sent when a unsupported Client 1 SFP is used.
1.3.6.1.4.1.11857.1.2.2.9.2.0.13Notificationtrm53005500TrapSfpFaultyClient1currentThis trap is sent when the Client 1 SFP is faulty.
1.3.6.1.4.1.11857.1.2.2.9.2.0.14Notificationtrm53005500TrapTxGlitchClient1currentThis trap is sent when a unit experiences a split second optical transmission glitch at the Client 1 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.15Notificationtrm53005500TrapRxGlitchClient1currentThis trap is sent when a unit experiences a split second optical input power glitch at the Client 1 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.16Notificationtrm53005500TrapTxDisabledClient1currentThis trap is sent when the optical output power for the client 1 interface have been disabled.
1.3.6.1.4.1.11857.1.2.2.9.2.0.17Notificationtrm53005500TrapRxLinkDownClient2currentThis trap is sent when the Client 2 Rx signal is out of sync or has been lost.
1.3.6.1.4.1.11857.1.2.2.9.2.0.18Notificationtrm53005500TrapTxOutOfSyncClient2currentThis trap is sent when the Client 2 tx output signal is outside the selected frequencey range.
1.3.6.1.4.1.11857.1.2.2.9.2.0.19Notificationtrm53005500TrapSfpMissingClient2currentThis trap is sent when the Client 2 SFP transiever not is mounted.
1.3.6.1.4.1.11857.1.2.2.9.2.0.20Notificationtrm53005500TrapSfpBadTypeClient2currentThis trap is sent when a unsupported Client 2 SFP is used.
1.3.6.1.4.1.11857.1.2.2.9.2.0.21Notificationtrm53005500TrapSfpFaultyClient2currentThis trap is sent when the Client 2 SFP is faulty.
1.3.6.1.4.1.11857.1.2.2.9.2.0.22Notificationtrm53005500TrapTxGlitchClient2currentThis trap is sent when a unit experiences a split second optical transmission glitch at the Client 2 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.23Notificationtrm53005500TrapRxGlitchClient2currentThis trap is sent when a unit experiences a split second optical input power glitch at the Client 2 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.24Notificationtrm53005500TrapTxDisabledClient2currentThis trap is sent when the optical output power for the client 2 interface have been disabled.
1.3.6.1.4.1.11857.1.2.2.9.2.0.25Notificationtrm53005500TrapRxLinkDownClient3currentThis trap is sent when the Client 3 Rx signal is out of sync or has been lost.
1.3.6.1.4.1.11857.1.2.2.9.2.0.26Notificationtrm53005500TrapTxOutOfSyncClient3currentThis trap is sent when the Client 3 tx output signal is outside the selected frequencey range.
1.3.6.1.4.1.11857.1.2.2.9.2.0.27Notificationtrm53005500TrapSfpMissingClient3currentThis trap is sent when the Client 3 SFP transiever not is mounted.
1.3.6.1.4.1.11857.1.2.2.9.2.0.28Notificationtrm53005500TrapSfpBadTypeClient3currentThis trap is sent when a unsupported Client 3 SFP is used.
1.3.6.1.4.1.11857.1.2.2.9.2.0.29Notificationtrm53005500TrapSfpFaultyClient3currentThis trap is sent when the Client 3 SFP is faulty.
1.3.6.1.4.1.11857.1.2.2.9.2.0.30Notificationtrm53005500TrapTxGlitchClient3currentThis trap is sent when a unit experiences a split second optical transmission glitch at the Client 3 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.31Notificationtrm53005500TrapRxGlitchClient3currentThis trap is sent when a unit experiences a split second optical input power glitch at the Client 3 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.32Notificationtrm53005500TrapTxDisabledClient3currentThis trap is sent when the optical output power for the client 3 interface have been disabled.
1.3.6.1.4.1.11857.1.2.2.9.2.0.33Notificationtrm53005500TrapRxLinkDownClient4currentThis trap is sent when the Client 4 Rx signal is out of sync or has been lost.
1.3.6.1.4.1.11857.1.2.2.9.2.0.34Notificationtrm53005500TrapTxOutOfSyncClient4currentThis trap is sent when the Client 4 tx output signal is outside the selected frequencey range.
1.3.6.1.4.1.11857.1.2.2.9.2.0.35Notificationtrm53005500TrapSfpMissingClient4currentThis trap is sent when the Client 4 SFP transiever not is mounted.
1.3.6.1.4.1.11857.1.2.2.9.2.0.36Notificationtrm53005500TrapSfpBadTypeClient4currentThis trap is sent when a unsupported Client 4 SFP is used.
1.3.6.1.4.1.11857.1.2.2.9.2.0.37Notificationtrm53005500TrapSfpFaultyClient4currentThis trap is sent when the Client 4 SFP is faulty.
1.3.6.1.4.1.11857.1.2.2.9.2.0.38Notificationtrm53005500TrapTxGlitchClient4currentThis trap is sent when a unit experiences a split second optical transmission glitch at the Client 4 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.39Notificationtrm53005500TrapRxGlitchClient4currentThis trap is sent when a unit experiences a split second optical input power glitch at the Client 4 interface.
1.3.6.1.4.1.11857.1.2.2.9.2.0.40Notificationtrm53005500TrapTxDisabledClient4currentThis trap is sent when the optical output power for the client 4 interface have been disabled.
1.3.6.1.4.1.11857.1.2.2.9.2.0.41Notificationtrm53005500TrapHwFailurecurrentThis trap is sent when the unit got a hardware failure.
1.3.6.1.4.1.11857.1.2.3NodetrmSubrackFM
1.3.6.1.4.1.11857.1.2.3.0NodetrmSubrackTraps
1.3.6.1.4.1.11857.1.2.3.0.1NotificationtrmTrapBmiLostcurrentThis trap is sent when communication with a unit is lost.
1.3.6.1.4.1.11857.1.2.3.0.2NotificationtrmTrapBmiErrorcurrentThis trap is sent when a internal BMI error occur.
1.3.6.1.4.1.11857.1.2.3.0.3NotificationtrmTrapHighTempcurrentThis trap is sent when a high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement.
1.3.6.1.4.1.11857.1.2.3.0.4NotificationtrmTrapLowTempcurrentThis trap is sent when a low temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement.
1.3.6.1.4.1.11857.1.2.3.0.5NotificationtrmTrapVeryHighTempcurrentThis trap is sent when a very high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement.
1.3.6.1.4.1.11857.1.2.3.0.6NotificationtrmTrapSpeedLimitExceededcurrentThis trap is sent if the Client bitrate is higher than a predefined protocol. When the alarm is activated Line and Client Tx is disabled. The alarm is ceased a…
Type Definitions
NameSyntaxStatusDescription
AlarmAcknowledgeINTEGER {acknowledge (1)}currentIndicates if a alarm is acknowledged or not. Can be either yes or no
AlarmClassINTEGER {unknown (0) , communications (1) , qos (2) , processing (3) , equipment (4) , environmental (5)}currentThe AlarmClass type categorizes the alarm, and is defined when the alarm is registered. It is as defined in X.733, ITU Alarm Reporting Function: o communications. An alarm of this class is principally associated with th…
AlarmSeverityINTEGER {critical (1) , major (2) , minor (3) , warning (4), none(5)}currentThe AlarmSeverity maps directly to the perceived severity field but includes an additional element for information alarms. See The perceived alarm severity textual convention for a description of the other types. o The …
AlarmStatusINTEGER {active (1) , ceased (2)}currentSwitch, that can be active or ceased
BoardNumberINTEGER (1..12)currentBoard position in rack
CascadeModeINTEGER { activate(1), deactivate(2) }currentCascade Mode.
CascadeStatusINTEGER { deactivated(1), initializing(2), ok(3), failure(4), disconnecting(5) }currentCascade status.
CDR55ModeINTEGER { escon(1), stm1orOC-3(2), fddiOR100Base-FX(3),syncSignal16-32Mbps(4)}currentDifferent CDR settings.
CDRModeINTEGER { auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11), gigabitEthernetx2(12) }currentDifferent CDR settings.
ExternalAlarmLevelINTEGER {activelow (1) , activehigh (2)}currentExternal alarm level. Indicates at which level a alarm shoud be active on
LineLoopModeINTEGER {normal (1) , looptest (2)}currentLine loop mode can be normal(1) or forced(2).
MuxTypeINTEGER {none (1), mux8030 (2) , mux8031 (3) , mux8032(4) , mux8033(5), mux8034(6) }currentMux Type. Indicates the Mux type.
OwnerStringDisplayString (SIZE (0 .. 127 ))currentAn OwnerString identifies the initiator or owner of a row in a table. This label is set by the initiator to provide for the following possibilities: o A management station may recognize resources it owns and no longer n…
PerceivedSeverityINTEGER {indeterminate (0) , critical (1) , major (2) , minor (3) , warning (4), cleared (5)}currentThe PerceivedSeverity defines six severity levels, which provide an indication of how it is perceived that the capability of the managed object has been affected. Those severity levels which represent service affecting …
PortTypeINTEGER {line (1) , client (2)}currentType of port
PowerStatusINTEGER {off (1) , on (2)}currentPower Status. Indicates if power is on or off
PowerTypeINTEGER {unknown (1), power9048 (2) , power9220 (3), power9148(4), power9122(5)}currentPower Type. Indicates the type of power.
PresentINTEGER {yes (1) , no (2)}currentIndicates if a unit is present(yes) or not(no).
RackNumberINTEGER (1..5)currentRack Number
RowStatusINTEGER {active (1) , notInService (2) , notReady (3) , createAndGo (4) , createAndWait (5) , destroy (6)}current
SecurityModeINTEGER { activated(1), deactivated(2) }currentSecurity Mode.
SlotNumberINTEGER (1..17)currentSlot position in rack
SlotNumberNmbINTEGER (9..13)currentNetwork management board slot position in rack
SlotNumberPSINTEGER (10..15)currentPower supply slot position in rack
SpeedLimit75INTEGER { noLimit(1), lowLimit(2), mediumLimit(3) }currentSpeed Limit.
SpeedLimit76INTEGER { noLimit(1), lowLimit(2), mediumLimit(3), highLimit(4) }currentSpeed Limit.
SwitchINTEGER {off (1) , on (2)}currentSwitch, that can be turned either on or off
TrafficStatusINTEGER {notraffic (1) , traffic (2)}currentTraffic Status. Indicates if there is traffic(2) or not, notraffic(1).
TrmDateDisplayString (SIZE (0..10))currentDate on format YYYY-MM-DD.
TrmTimeDisplayString (SIZE(0..8))currentDate on format HH:MM:SS.
TxMode75INTEGER {normal (1) , disabled (2) }currentMode of the optical transmitter. normal(1)= On if Receiving signal. disabled (2) = Always off.
TxMode76INTEGER {normal (1) , disabled (2) , forcedon (3) }currentMode of the optical transmitter. normal(1) = On if Receiving signal. disabled(2) = Always off. enabled(3) = Always on(testmode).