TY1250I-MIB
120 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.466 | Nodetylink | |||
| 1.3.6.1.4.1.466.1 | Nodedsucsu | |||
| 1.3.6.1.4.1.466.2 | Nodetyview | |||
| 1.3.6.1.4.1.466.3 | Nodety1250 | |||
| 1.3.6.1.4.1.466.3.0 | Nodety1250Trap | A ty1250Trap trap signifies that the sending node had its `ty1250AlarmType` variable modified. | ||
| 1.3.6.1.4.1.466.3.1 | Nodety1250LineFailureTrap | The line has failed. | ||
| 1.3.6.1.4.1.466.3.1 | Nodety1250SysTable | |||
| 1.3.6.1.4.1.466.3.1.1 | Scalarty1250SysType | read-only | mandatory | A textual description of the system model identifier. for example: TYLINK1250 |
| 1.3.6.1.4.1.466.3.1.2 | Scalarty1250SysSoftRev | read-only | mandatory | Displays the Software Revision installed in this node. |
| 1.3.6.1.4.1.466.3.1.3 | Scalarty1250SysHardRev | read-only | mandatory | Displays the Hardware Revision of the node. |
| 1.3.6.1.4.1.466.3.1.4 | Scalarty1250SysNumNetInstalled | read-only | mandatory | The number of Network (DDS) ports that are installed. There is 1 on the 1250. |
| 1.3.6.1.4.1.466.3.1.5 | Scalarty1250SysNumDteInstalled | read-only | mandatory | The number of channels (DTE) that are installed. There is 1 on the 1250. |
| 1.3.6.1.4.1.466.3.1.6 | Scalarty1250SysNumMaintInstalled | read-only | mandatory | The number of Maintenance ports that are installed. There are 2 on the 1250. |
| 1.3.6.1.4.1.466.3.1.7 | Scalarty1250SysName | read-write | mandatory | The user supplied name of the node. This object does not affect operation, but may be useful for network management. |
| 1.3.6.1.4.1.466.3.2 | Nodety1250CfgAppTable | |||
| 1.3.6.1.4.1.466.3.2 | Nodety1250LineInServiceTrap | The line is back in service. | ||
| 1.3.6.1.4.1.466.3.2.2 | Scalarty1250CfgAppClockSource | read-write | mandatory | Default timing, or clock, source. There must be only one source on a DDS line. Node should always be network (2) timed on a point-to-network application. Line … |
| 1.3.6.1.4.1.466.3.2.3 | Scalarty1250CfgAppCircuitId | read-write | mandatory | Circuit identifier provided by the service provider. |
| 1.3.6.1.4.1.466.3.3 | Nodety1250CfgNetTable | |||
| 1.3.6.1.4.1.466.3.3 | Nodety1250ConnectedTrap | The 1250 unit is connected. | ||
| 1.3.6.1.4.1.466.3.3.4 | Scalarty1250CfgNetGlareType | read-write | mandatory | In switched applications, defines who wins when there are simultanious incomming and outgoing calls. If in doubt, select external-glare (2). |
| 1.3.6.1.4.1.466.3.3.5 | Scalarty1250CfgNetEchoCan | read-write | mandatory | In switched applications, some carriers, such as Sprint, require you to disable-echo-cancellors (2) for data apps on most lines. Calls take longer to come up w… |
| 1.3.6.1.4.1.466.3.3.6 | Scalarty1250CfgNetAnsMode | read-write | mandatory | In switched applications, allows for manual-answer (1) or automatic-answer (2) of inbound calls. Calls may be answered in manual mode via vt100, DTR, or the fr… |
| 1.3.6.1.4.1.466.3.3.7 | Scalarty1250CfgNetDialTimeout | read-write | mandatory | In switched applications, time in seconds to wait for far end to answer before giving up, and possibly redialing. |
| 1.3.6.1.4.1.466.3.3.8 | Scalarty1250CfgNetNumRedial | read-write | mandatory | In switched applications, number of times to redial if the call fails. |
| 1.3.6.1.4.1.466.3.3.9 | Scalarty1250CfgNetRedialDelay | read-write | mandatory | In switched applications, delay in seconds between redial attempts. |
| 1.3.6.1.4.1.466.3.3.10 | Scalarty1250CfgNetDefNum2Dial | read-write | mandatory | In switched applications, default phone number to dial. Numbers and dashes are allowed. |
| 1.3.6.1.4.1.466.3.3.11 | Scalarty1250CfgNetType | read-write | mandatory | Indicates type of service purchased on the attached network line (DDS or SW56). Valid selections are dedicated (1) and switch56 (2). |
| 1.3.6.1.4.1.466.3.3.12 | Scalarty1250CfgNetBPVThresholding | read-write | mandatory | Allows the user to turn on and off the BPV thresholding function. Valid values are thresholding_at_10E-4 (1) and disable-thresholding (2). |
| 1.3.6.1.4.1.466.3.4 | Nodety1250CfgDteTable | |||
| 1.3.6.1.4.1.466.3.4 | Nodety1250ConnectFailureTrap | The attempted connection failed. | ||
| 1.3.6.1.4.1.466.3.4.1 | Scalarty1250CfgDteType | read-only | mandatory | The Dte channel type identifies the electrical specification of the interface. Read-only. |
| 1.3.6.1.4.1.466.3.4.5 | Scalarty1250CfgDteClockInvert | read-write | mandatory | Clock Inversion, invert-dte-clock (2), can be used to solve out of phase timing problems on DTE link. normal-dte-clock (1) can be used in most cases. |
| 1.3.6.1.4.1.466.3.4.6 | Scalarty1250CfgDteTiming | read-write | mandatory | The DTE channel Timing mode. Use loop2-timing (2) when in doubt. |
| 1.3.6.1.4.1.466.3.5 | Nodety1250CfgDialTable | |||
| 1.3.6.1.4.1.466.3.5 | Nodety1250IncomingCallTrap | Incoming call. | ||
| 1.3.6.1.4.1.466.3.5.1 | Scalarty1250CfgDialButton | read-write | mandatory | In switched applications, Enables/Disables the button on front of unit. This button can used to manual answer an incomming call, or dial out the default number… |
| 1.3.6.1.4.1.466.3.5.2 | Scalarty1250CfgDialDtr | read-write | mandatory | In switched applications, Enables/Disables dialing on DTR signal transition. Valid values enable-dtr (1) and disable-dtr (2). |
| 1.3.6.1.4.1.466.3.5.3 | Scalarty1250CfgDialRtsDisc | read-write | mandatory | In switched applications, Enables/Disables disconnecting on RTS signal transition. Valid values are enable-rts (1) and disable-rts (2). |
| 1.3.6.1.4.1.466.3.5.4 | Scalarty1250CfgDialRi | read-write | mandatory | In switched applications, Enables/Disables incoming call notification to DTE via RI signal. Valid values are enable-ri (1) and disable-ri (2). |
| 1.3.6.1.4.1.466.3.6 | Tablety1250CfgMaintTable | not-accessible | mandatory | The Maintenance Port Configuration table contains parameters for the Maintenance ports on the 1250. The Terminal Port is Index=1; SLIP port is 2 |
| 1.3.6.1.4.1.466.3.6 | Nodety1250DisconnectedTrap | Disconnected. | ||
| 1.3.6.1.4.1.466.3.6.1 | Rowty1250CfgMaintEntry | not-accessible | mandatory | Maintenance Port Configuration Object |
| 1.3.6.1.4.1.466.3.6.1.1 | Columnty1250CfgMaintIndex | read-only | mandatory | The Maintenance port under consideration. On the 1250, the Terminal Port is Index=1; SLIP port is 2. |
| 1.3.6.1.4.1.466.3.6.1.2 | Columnty1250CfgMaintMode | read-write | mandatory | The Mode for this Maintenance Port. Values include ascii-vt100 (4), slip (7), and cslip (8). |
| 1.3.6.1.4.1.466.3.6.1.3 | Columnty1250CfgMaintBaud | read-write | mandatory | Baud rate for this Maintenance port. Values are baud-2400 (2), baud-9600 (4), baud-19200 (5). |
| 1.3.6.1.4.1.466.3.6.1.4 | Columnty1250CfgMaintDataBits | read-write | mandatory | Databits for this Maintenance port. Values are databits-7 (1) and databits-8 (2). |
| 1.3.6.1.4.1.466.3.6.1.5 | Columnty1250CfgMaintStopBits | read-write | mandatory | Number of Stopbits for this Maintenance port. Values are stopbits-1 (1), stopbits-1-5 (2), and stopbits-2 (3). |
| 1.3.6.1.4.1.466.3.6.1.6 | Columnty1250CfgMaintParity | read-write | mandatory | Parity for this Maintenance port. Values are no-parity (1), odd-parity (2), even-parity (3). |
| 1.3.6.1.4.1.466.3.6.1.7 | Columnty1250CfgMaintFlowCtrl | read-write | mandatory | Flow Control for this Maintenance port. Values are no-flow-control (1), software-flow-control (2), and hardware-flow-control (3). |
| 1.3.6.1.4.1.466.3.7 | Nodety1250BadConfigTrap | The configuration specified in the SET command was bad. SET failed. | ||
| 1.3.6.1.4.1.466.3.8 | Nodety1250CfgSlipTable | |||
| 1.3.6.1.4.1.466.3.8 | Nodety1250LocalConfigTrap | The configuration has been changed by a means other than SNMP. | ||
| 1.3.6.1.4.1.466.3.8.1 | Scalarty1250CfgSlipMyIP | read-write | mandatory | The IP address for this node. |
| 1.3.6.1.4.1.466.3.8.2 | Scalarty1250CfgSlipPeerIP | read-write | mandatory | The IP address for other end of slip connection. |
| 1.3.6.1.4.1.466.3.8.3 | Scalarty1250CfgSlipMask | read-write | mandatory | The IP Network Mask (eg 255.255.255.0) for the SLIP link. |
| 1.3.6.1.4.1.466.3.8.4 | Scalarty1250CfgSlipMaxMTU | read-write | mandatory | The Maximum Transmission Unit is the size of the largest IP packet supported. This value should be set to the lowest value supported by any equipment in the tr… |
| 1.3.6.1.4.1.466.3.9 | Nodety1250BPVThresholdExceededTrap | BPV threshold exceeded. | ||
| 1.3.6.1.4.1.466.3.9 | Nodety1250CallTable | |||
| 1.3.6.1.4.1.466.3.9.1 | Scalarty1250CallStatus | read-only | mandatory | The call status is shown here. |
| 1.3.6.1.4.1.466.3.9.2 | Scalarty1250CallNumber | read-write | mandatory | The last phone number dialed out. |
| 1.3.6.1.4.1.466.3.9.3 | Scalarty1250CallUpTime | read-only | mandatory | Number of seconds the call has been up. |
| 1.3.6.1.4.1.466.3.9.4 | Scalarty1250CallState | write-only | mandatory | Call-related actions: a: Connect (initiate a call), b: Disconnect (terminate a call) c: Answer (answer an incoming call). |
| 1.3.6.1.4.1.466.3.10 | Nodety1250BPVThresholdAcceptableTrap | BPV threshold acceptable. | ||
| 1.3.6.1.4.1.466.3.10 | Nodety1250DiagUnitTable | |||
| 1.3.6.1.4.1.466.3.10.1 | Scalarty1250DiagUnitLocLoop | read-write | mandatory | Enables the operator to control and examine the UNIT local loopback. This loopback occurs on all network ports transmit and receive logic. The unit will transm… |
| 1.3.6.1.4.1.466.3.10.2 | Scalarty1250DiagUnitReset | write-only | mandatory | Enables the operator to remotely reset the unit. Using this command will cause the unit to terminate all its connections and drop data. |
| 1.3.6.1.4.1.466.3.11 | Nodety1250DiagNetTable | |||
| 1.3.6.1.4.1.466.3.11 | Nodety1250LocalUnitLoopbackEnabledTrap | Local unit loopback enabled. | ||
| 1.3.6.1.4.1.466.3.11.1 | Scalarty1250DiagNetLineStatus | read-only | mandatory | The Current status of the physical interface. Your network carrier can send Out-of-Service or Maintenance Mode codes. |
| 1.3.6.1.4.1.466.3.11.2 | Scalarty1250DiagNetLclLpbk | read-write | mandatory | Enables the operator to control and examine the network local loopback. This loopback occurs on the net side of the local transmit and receive logic. The unit … |
| 1.3.6.1.4.1.466.3.11.3 | Scalarty1250DiagNetRmtLpbk | read-only | mandatory | Enables the operator to examine (ONLY) the status of network loopbacks placed by external equipment, such as your local CO. These loopbacks will loop received … |
| 1.3.6.1.4.1.466.3.12 | Nodety1250DiagDteTable | |||
| 1.3.6.1.4.1.466.3.12 | Nodety1250LocalUnitLoopbackDisabledTrap | Local unit loopback disabled. | ||
| 1.3.6.1.4.1.466.3.12.1 | Scalarty1250DiagDteSigRTS | read-only | mandatory | The Dte Channel RTS signal. Values are rts-signal-on (1) and rts-signal-off (2). |
| 1.3.6.1.4.1.466.3.12.2 | Scalarty1250DiagDteSigDTR | read-only | mandatory | The Dte Channel DTR signal. Values are dtr-signal-on (1) and dtr-signal-off (2). |
| 1.3.6.1.4.1.466.3.12.5 | Scalarty1250DiagDteLclLpbk | read-write | mandatory | This selection displays the status or controls the Local DTE Channel Loopback for the selected channel. This is will loop DTE data back towards the DTE interfa… |
| 1.3.6.1.4.1.466.3.12.6 | Scalarty1250DiagDteV54Lpbk | read-only | mandatory | This selection displays the status of the DTE Channel V.54 Loopback for the channel. This loopback is initiated by the remote node, causing this node to loop d… |
| 1.3.6.1.4.1.466.3.12.7 | Scalarty1250DiagDteBerState | write-only | mandatory | BERT test related actions: a: Starts a BERT test on a channel, b: Stops a BERT test on a channel, c: Inject Errors while the BERT test is running, d: Clears BE… |
| 1.3.6.1.4.1.466.3.12.8 | Scalarty1250DiagDteBerStatus | read-only | mandatory | Displays the current BERT test sync status. |
| 1.3.6.1.4.1.466.3.12.9 | Scalarty1250DiagDteBerErrors | read-only | mandatory | Displays the number of errors detected in Bert Test. |
| 1.3.6.1.4.1.466.3.12.10 | Scalarty1250DiagDteBerErrSec | read-only | mandatory | Displays the number of seconds containing errors in BERT Test. |
| 1.3.6.1.4.1.466.3.12.11 | Scalarty1250DiagDteBerTimeElaps | read-only | mandatory | Elapsed time since BERT test was started or cleared. |
| 1.3.6.1.4.1.466.3.12.12 | Scalarty1250DiagDteBerResyncs | read-only | mandatory | Displays the number of times BERT test has synched up on the pattern. |
| 1.3.6.1.4.1.466.3.12.13 | Scalarty1250DiagDteRmtV54Lpbk | write-only | mandatory | This selection controls the DTE Channel V.54 Remote Loopback. Transmit-code-enable (3) will cause the node to transmit a V.54 code to the remote node which wil… |
| 1.3.6.1.4.1.466.3.13 | Scalarty1250AlarmType | read-only | mandatory | The type of alarms that are generated on the node |
| 1.3.6.1.4.1.466.3.13 | Nodety1250LocalNetLoopbackEnabledTrap | Local network loopback enabled. | ||
| 1.3.6.1.4.1.466.3.14 | Nodety1250CfgSnmpTable | |||
| 1.3.6.1.4.1.466.3.14 | Nodety1250LocalNetLoopbackDisabledTrap | Local network loopback disabled. | ||
| 1.3.6.1.4.1.466.3.14.1 | Scalarty1250CfgSnmpManagerIP | read-write | mandatory | The IP address for the SNMP manager to receive this node's TRAPs. |
| 1.3.6.1.4.1.466.3.15 | Nodety1250SimplexCurrentLoopbackEnabledTrap | Simplex current loopback enabled. | ||
| 1.3.6.1.4.1.466.3.15 | Nodety1250StatsDteTable | |||
| 1.3.6.1.4.1.466.3.15.1 | Scalarty1250StatsDteTxByteCount | read-only | mandatory | The statistic counting the number of bytes transmitted on the DTE channel. |
| 1.3.6.1.4.1.466.3.15.2 | Scalarty1250StatsDteRxByteCount | read-only | mandatory | The statistic counting the number of bytes received on the DTE channel. |
| 1.3.6.1.4.1.466.3.15.3 | Scalarty1250StatsDteClearStats | write-only | mandatory | Allows the user to zero out all the statistics in the DTE statistics table. |
| 1.3.6.1.4.1.466.3.16 | Nodety1250SimplexCurrentLoopbackDisabledTrap | Simplex current loopback disabled. | ||
| 1.3.6.1.4.1.466.3.16 | Nodety1250StatsNetTable | |||
| 1.3.6.1.4.1.466.3.16.1 | Scalarty1250StatsNetLoopLength | read-only | mandatory | The statistic that estimates line attentuation on the network channel. |
| 1.3.6.1.4.1.466.3.16.2 | Scalarty1250StatsNetBpvCount | read-only | mandatory | The statistic counting the number of BPV errors on the network channel. |
| 1.3.6.1.4.1.466.3.16.3 | Scalarty1250StatsNetTxByteCount | read-only | mandatory | The statistic counting the number of bytes transmitted on the network channel. |
| 1.3.6.1.4.1.466.3.16.4 | Scalarty1250StatsNetRxByteCount | read-only | mandatory | The statistic counting the number of bytes received on the network channel. |
| 1.3.6.1.4.1.466.3.16.5 | Scalarty1250StatsNetClearStats | write-only | mandatory | Allows the user to zero out all the statistics in the network statistics table. |
| 1.3.6.1.4.1.466.3.17 | Nodety1250CfgTelnetTable | |||
| 1.3.6.1.4.1.466.3.17 | Nodety1250NonLatchingLoopbackEnabledTrap | Nonlatching loopback enabled. | ||
| 1.3.6.1.4.1.466.3.17.1 | Scalarty1250CfgTelnetEnable | read-write | mandatory | Enables/Disables the telnet feature. Valid values are enable-telnet (1) and disable-telnet (2). |
| 1.3.6.1.4.1.466.3.17.2 | Scalarty1250CfgTelnetAutoLogOut | read-write | mandatory | Enables/Disables the telnet auto-logout, logging out the user after a certain length of idle time. Valid values are autologout-at-15-minutes (1) and disable-au… |
| 1.3.6.1.4.1.466.3.18 | Nodety1250NonLatchingLoopbackDisabledTrap | Nonlatching loopback disabled. | ||
| 1.3.6.1.4.1.466.3.19 | Nodety1250V54LoopUpInitiatedTrap | Starting to loop up a V54 loopback on the remote unit. | ||
| 1.3.6.1.4.1.466.3.20 | Nodety1250V54LoopDownCompletedTrap | Completed the loop down of a V54 loopback on the remote unit. | ||
| 1.3.6.1.4.1.466.3.21 | Nodety1250V54LoopbackEnabledTrap | V54 loopback enabled by remote unit. | ||
| 1.3.6.1.4.1.466.3.22 | Nodety1250V54LoopbackDisabledTrap | V54 loopback disabled by remote unit. | ||
| 1.3.6.1.4.1.466.3.23 | Nodety1250BertInitiatedTrap | BERT test pattern initiated. | ||
| 1.3.6.1.4.1.466.3.24 | Nodety1250BertCompletedTrap | BERT test pattern completed. | ||
| 1.3.6.1.4.1.466.3.25 | Nodety1250LocalDteLoopbackEnabledTrap | Local DTE loopback enabled. | ||
| 1.3.6.1.4.1.466.3.26 | Nodety1250LocalDteLoopbackDisabledTrap | Local DTE loopback disabled. | ||
| 1.3.6.1.4.1.466.3.27 | Nodety1250LocalUnitLoopbackFailedTrap | Unable to do a local unit loopback. | ||
| 1.3.6.1.4.1.466.3.28 | Nodety1250LocalNetLoopbackFailedTrap | Unable to do a local network loopback. | ||
| 1.3.6.1.4.1.466.3.29 | Nodety1250BertFailedTrap | Unable to do a BERT. | ||
| 1.3.6.1.4.1.466.3.30 | Nodety1250LocalDteLoopbackFailedTrap | Unable to do a local DTE loopback. | ||
| 1.3.6.1.4.1.466.3.31 | Nodety1250V54LoopbackFailedTrap | Unable to do a V54 loopback. |