MIB Viewer

UBQS-ENTITY-MIB

76 objects
The UBQS-ENTITY-MIB is used to monitor and configure operational status of Field Replaceable Units (FRUs) and other managable physical entities of the system listed in the Entity-MIB (RFC 2737) entPhysicalTable.
Imported Objects
ENTITY-MIBentPhysicalContainedIn entPhysicalDescr entPhysicalIndex entPhysicalName
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TimeStamp TruthValue
UBQS-SMIubiMgmtv2
OIDNameAccessStatusDescription
1.3.6.1.4.1.7800.100.3IdentityubiEntityMIBThe UBQS-ENTITY-MIB is used to monitor and configure operational status of Field Replaceable Units (FRUs) and other managable physical entities of the system l…
1.3.6.1.4.1.7800.100.3.1NodeubiEntityMIBObjects
1.3.6.1.4.1.7800.100.3.1.1NodeubiEntityNotificationEnables
1.3.6.1.4.1.7800.100.3.1.1.1ScalarubiFRUControlEnabledread-writecurrentThis variable indicates whether the system produces the following notifications: ubiEntityFRUInserted, ubiEntityFRURemoved. A false value will prevent these no…
1.3.6.1.4.1.7800.100.3.1.1.2ScalarubiEntSensorThresholdNotificationEnabledread-writecurrentThis variable indicates whether the system produces the following notification: ubiEntSensorThreshold. A false value will prevent these notifications from bein…
1.3.6.1.4.1.7800.100.3.1.2TableubiModuleTablenot-accessiblecurrentThis table contains one row per module entity.
1.3.6.1.4.1.7800.100.3.1.2.1RowubiModuleEntrynot-accessiblecurrentInformation about a particular module entity.
1.3.6.1.4.1.7800.100.3.1.2.1.1ColumnubiModuleIdread-onlycurrentThe unique module ID.
1.3.6.1.4.1.7800.100.3.1.2.1.2ColumnubiModuleTyperead-onlycurrentThe textual type of this module.
1.3.6.1.4.1.7800.100.3.1.2.1.3ColumnubiModuleOperStatusread-onlycurrentThe operational state of this module.
1.3.6.1.4.1.7800.100.3.1.2.1.4ColumnubiModuleStatusLastChangeTimeread-onlycurrentThe value of sysUpTime when ubiModuleOperStatus is changed.
1.3.6.1.4.1.7800.100.3.1.2.1.5ColumnubiModuleSerialNumberread-onlycurrentThe serial number of this module.
1.3.6.1.4.1.7800.100.3.1.2.1.6ColumnubiModuleSlotNumberread-onlycurrentThis value is determined by the number of slot where the module is located.
1.3.6.1.4.1.7800.100.3.1.2.1.7ColumnubiModulePortNumberread-onlycurrentThis value is determined by the number of port where the module is located.
1.3.6.1.4.1.7800.100.3.1.2.1.8ColumnubiModuleActionread-writecurrentThis object, when read, returns one of the following results: other(1): module permanently enabled Setting this object to one of the acceptable values gives th…
1.3.6.1.4.1.7800.100.3.1.3TableubiSlotTablenot-accessiblecurrentThis table contains one row per slot entity.
1.3.6.1.4.1.7800.100.3.1.3.1RowubiSlotEntrynot-accessiblecurrentInformation about a particular slot entity.
1.3.6.1.4.1.7800.100.3.1.3.1.1ColumnubiSlotModuleIdread-onlycurrentThe unique module ID.
1.3.6.1.4.1.7800.100.3.1.3.1.2ColumnubiSlotIdread-onlycurrentThe unique slot ID.
1.3.6.1.4.1.7800.100.3.1.3.1.3ColumnubiSlotTyperead-onlycurrentThe textual type of this slot.
1.3.6.1.4.1.7800.100.3.1.3.1.4ColumnubiSlotOperStatusread-onlycurrentThe status of this slot.
1.3.6.1.4.1.7800.100.3.1.3.1.5ColumnubiSlotPortNumberread-onlycurrentThis value is determined by the number of port where the slot is located.
1.3.6.1.4.1.7800.100.3.1.3.1.6ColumnubiSlotSerialNumberread-writecurrentThe serial number of this slot.
1.3.6.1.4.1.7800.100.3.1.4NodeubiExtSlot
1.3.6.1.4.1.7800.100.3.1.4.1ScalarubiIEEE1588SlotOperStatusread-onlycurrentThe operational status of the slot for IEEE 1588 specification.
1.3.6.1.4.1.7800.100.3.1.4.2ScalarubiMngSlotOperStatusread-onlycurrentThe operational status of the slot for mng specification.
1.3.6.1.4.1.7800.100.3.1.5NodeubiTransceiver
1.3.6.1.4.1.7800.100.3.1.5.1TableubiEntitySensorTablenot-accessiblecurrentThis table contains objects which provide information about the transceiver sensor of physical entity.
1.3.6.1.4.1.7800.100.3.1.5.1.1RowubiEntitySensorEntrynot-accessiblecurrentAn entry containing management information applicable to the transceiver sensor of a particular physical entity.
1.3.6.1.4.1.7800.100.3.1.5.1.1.1ColumnubiEntSensorTyperead-onlycurrentThis variable indicates the type of data reported by the entSensorValue. valid values are: other(1): a measure other than those listed below unknown(2): unknow…
1.3.6.1.4.1.7800.100.3.1.5.1.1.2ColumnubiEntSensorScaleread-onlycurrentThis variable indicates the exponent to apply to sensor values reported by entSensorValue.
1.3.6.1.4.1.7800.100.3.1.5.1.1.3ColumnubiEntSensorValueread-onlycurrentThis variable reports the most recent measurement seen by the sensor.
1.3.6.1.4.1.7800.100.3.1.5.1.1.4ColumnubiEntSensorEventStatusread-onlycurrentThis variable indicates the present current event status of the sensor.
1.3.6.1.4.1.7800.100.3.1.5.1.1.5ColumnubiEntSensorEventUpdateTimeread-onlycurrentThe value of sysUpTime when the status of entity sensor is changed.
1.3.6.1.4.1.7800.100.3.1.5.1.1.6ColumnubiEntSensorAlarmHighThresholdread-writecurrentThis variable indicates the value of the high alarm threshold.
1.3.6.1.4.1.7800.100.3.1.5.1.1.7ColumnubiEntSensorWarningHighThresholdread-writecurrentThis variable indicates the value of the high warning threshold.
1.3.6.1.4.1.7800.100.3.1.5.1.1.8ColumnubiEntSensorWarningLowThresholdread-writecurrentThis variable indicates the value of the low warning threshold.
1.3.6.1.4.1.7800.100.3.1.5.1.1.9ColumnubiEntSensorAlarmLowThresholdread-writecurrentThis variable indicates the value of the low alarm threshold.
1.3.6.1.4.1.7800.100.3.1.5.1.1.10ColumnubiEntSensorNameread-onlycurrentThis variable indicates the name of the sensor entity.
1.3.6.1.4.1.7800.100.3.1.5.2TableubiTransceiverInfoTablenot-accessiblecurrentThis table contains objects which provide information about the transceiver of physical entity.
1.3.6.1.4.1.7800.100.3.1.5.2.1RowubiTransceiverInfoEntrynot-accessiblecurrentAn entry containing management information applicable to the transceiver of a particular physical entity.
1.3.6.1.4.1.7800.100.3.1.5.2.1.1ColumnubiTcIdentifierread-onlycurrentThis variable indicates the transceiver indentifier. valid value are: unknown(0), other(1), gbic(2), module(3), sfp(4), xbi(5), xenpak(6), xfp(7), xff(8), xfp_…
1.3.6.1.4.1.7800.100.3.1.5.2.1.2ColumnubiTcVendorOUIread-onlycurrentThis variable indicates a textual string containing information about the IEEE company ID of transceiver vendor
1.3.6.1.4.1.7800.100.3.1.5.2.1.3ColumnubiTcVendorNameread-onlycurrentA textual string containing information about the transceiver name.
1.3.6.1.4.1.7800.100.3.1.5.2.1.4ColumnubiTcVendorPartNumberread-onlycurrentA textual string containing information about the part number of the transceiver.
1.3.6.1.4.1.7800.100.3.1.5.2.1.5ColumnubiTcVendorRevisionLevelread-onlycurrentA textual string containing information about the revision level of the transceiver part number.
1.3.6.1.4.1.7800.100.3.1.5.2.1.6ColumnubiTcVendorSerialNumberread-onlycurrentThis variable indicates a textual string containing information about the transceiver serial number.
1.3.6.1.4.1.7800.100.3.1.5.2.1.7ColumnubiTcVendorManufacturingDateread-onlycurrentThis variable indicates a manufacturing date of transceiver
1.3.6.1.4.1.7800.100.3.1.5.2.1.8ColumnubiTcWaveLengthread-onlycurrentThis variable indicates a wave length of transceiver.
1.3.6.1.4.1.7800.100.3.1.5.2.1.9ColumnubiTcConnectorread-onlycurrentThis variable indicates a connector type of transceiver.
1.3.6.1.4.1.7800.100.3.1.5.2.1.10ColumnubiTcLengthread-onlycurrentThis variable indicates a length of transceiver.
1.3.6.1.4.1.7800.100.3.1.5.3ScalarubiTransceiverMonitoringread-writecurrentThis variable indicates whether the system produces the log and notification for transceiver sensor.
1.3.6.1.4.1.7800.100.3.2NodeubiEntityMIBNotificationPrefix
1.3.6.1.4.1.7800.100.3.2.0NodeubiFruNotifications
1.3.6.1.4.1.7800.100.3.2.0.1NotificationubiFRUInsertedcurrentThe ubiEntityFRUInserted notification indicates that a FRU was inserted. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, …
1.3.6.1.4.1.7800.100.3.2.0.2NotificationubiFRURemovedcurrentThe ubiEntityFRURemoved notification indicates that a FRU was removed. The varbind for this notification indicates the entPhysicalIndex of the removed FRU, and…
1.3.6.1.4.1.7800.100.3.2.1NodeubiEntitySensorNotifications
1.3.6.1.4.1.7800.100.3.2.1.1NotificationubiEntSensorThresholdcurrentThe ubiEntSensorThreshold notification indicates that the status of transceiver sensor was changed.
1.3.6.1.4.1.7800.100.3.3NodeubiEntityMIBConformance
1.3.6.1.4.1.7800.100.3.3.1NodeubiEntityMIBCompliances
1.3.6.1.4.1.7800.100.3.3.1.1ComplianceubiEntityMIBCompliancecurrentAn Entity-MIB implementation can implement this group to provide FRU status and control.
1.3.6.1.4.1.7800.100.3.3.2NodeubiEntityMIBGroups
1.3.6.1.4.1.7800.100.3.3.2.1GroupubiEntityMIBModuleGroupcurrentThe collection of objects which are used to get the operational state and redundancy state of the modules
1.3.6.1.4.1.7800.100.3.3.2.2GroupubiEntitySlotGroupcurrentThe collection of objects which are used to get the operational state and redundancy state of the slot.
1.3.6.1.4.1.7800.100.3.3.2.3GroupubiEntityMIBNotificationGroupcurrentTThe collection of objects which are used to send a notification.
1.3.6.1.4.1.7800.100.3.3.2.4GroupubiEntiryMIBIEEE1588SlotGroupcurrentThe collection of objects which are used to get the operational state of the slot for IEEE 1588.
1.3.6.1.4.1.7800.100.3.3.2.5GroupubiEntityMIBTransceiverGroupcurrentThe collection of objects which are used to get the information of transceiver.
Type Definitions
NameSyntaxStatusDescription
ModuleOperTypeINTEGER { other(1), ok(2), disabled(3) }currentOperational module states. Valid values are : unknown(1) Module is not in one of other states normal operational states: ok(2) Module is operational. disabled(3) Module is administratively disabled. selfTest(6) Module i…
UbiSensorDataScaleINTEGER { yocto(1), zepto(2), atto(3), femto(4), pico(5), nano(6), micro(7), milli(8), units(9), kilo(10), mega(11), giga(12), tera(13), exa(14), peta(15), zetta(16), yotta(17) }currentInternational System of Units (SI) prefixes.
UbiSensorDataTypeINTEGER { other(1), unknown(2), volts(3), amperes(4), celsius(5), dBm(6), percentRH(8), rpm(9), cmm(10), truthvalue(11), specialEnum(12), watts(13), hertz(14) }currentsensor measurement data types. valid values are: other(1): a measure other than those listed below unknown(2): unknown measurement, or arbitrary, relative numbers volts(3): electric potential amperes(4): electric curren…
UbiSensorPrecisionINTEGER (-8..9)currentWhen in the range 1 to 9, SensorPrecision is the number of decimal places in the fractional part of a SensorValue fixed-point number. When in the range -8 to -1, SensorPrecision is the number of accurate digits in a Sen…
UbiSensorValueOCTET STRINGcurrentRepresent the sensor value
UbiSensorValue_ciscoINTEGER (-1000000000..1000000000)currentFor sensors that measure voltsAC, voltsDC, amperes, watts, hertz, celsius, cmm this item is a fixed point number ranging from -999,999,999 to +999,999,999. Use the value -1000000000 to indicate underflow. Use the value …
UbiTcConnectorTypeINTEGER { unknown(0), other(1), sc(2), fiber_style1_copper(3), fiber_stype2_copper(4), bnc_tnc(5), fiber_coaxial(6), fiberjack(7), lc(8), mt_rj(9), sg(10), optical_pigtail(11), hssdc2(12), copper_pigtail(13) }current
UbiTcEncodingTypeINTEGER { unknown(0), other(1), enc_64b(2), enc_4b5b(3), enc_8b10b(4), enc_sonet(5), enc_nrz(6), enc_rz(7), enc_manchester(8) }current
UbiTcIdentifierINTEGER { unknown(0), other(1), gbic(2), module(3), sfp(4), xbi(5), xenpak(6), xfp(7), xff(8), xfp_e(9), xpak(10), x2(11) }current