UBQS-ENTITY-MIB
76 objects
The UBQS-ENTITY-MIB is used to monitor and configure operational status of Field Replaceable Units (FRUs) and other managable physical entities of the system listed in the Entity-MIB (RFC 2737) entPhysicalTable.
Imported Objects
| ENTITY-MIB | entPhysicalContainedIn entPhysicalDescr entPhysicalIndex entPhysicalName |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION TimeStamp TruthValue |
| UBQS-SMI | ubiMgmtv2 |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7800.100.3 | IdentityubiEntityMIB | The UBQS-ENTITY-MIB is used to monitor and configure operational status of Field Replaceable Units (FRUs) and other managable physical entities of the system l… | ||
| 1.3.6.1.4.1.7800.100.3.1 | NodeubiEntityMIBObjects | |||
| 1.3.6.1.4.1.7800.100.3.1.1 | NodeubiEntityNotificationEnables | |||
| 1.3.6.1.4.1.7800.100.3.1.1.1 | ScalarubiFRUControlEnabled | read-write | current | This variable indicates whether the system produces the following notifications: ubiEntityFRUInserted, ubiEntityFRURemoved. A false value will prevent these no… |
| 1.3.6.1.4.1.7800.100.3.1.1.2 | ScalarubiEntSensorThresholdNotificationEnabled | read-write | current | This variable indicates whether the system produces the following notification: ubiEntSensorThreshold. A false value will prevent these notifications from bein… |
| 1.3.6.1.4.1.7800.100.3.1.2 | TableubiModuleTable | not-accessible | current | This table contains one row per module entity. |
| 1.3.6.1.4.1.7800.100.3.1.2.1 | RowubiModuleEntry | not-accessible | current | Information about a particular module entity. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.1 | ColumnubiModuleId | read-only | current | The unique module ID. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.2 | ColumnubiModuleType | read-only | current | The textual type of this module. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.3 | ColumnubiModuleOperStatus | read-only | current | The operational state of this module. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.4 | ColumnubiModuleStatusLastChangeTime | read-only | current | The value of sysUpTime when ubiModuleOperStatus is changed. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.5 | ColumnubiModuleSerialNumber | read-only | current | The serial number of this module. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.6 | ColumnubiModuleSlotNumber | read-only | current | This value is determined by the number of slot where the module is located. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.7 | ColumnubiModulePortNumber | read-only | current | This value is determined by the number of port where the module is located. |
| 1.3.6.1.4.1.7800.100.3.1.2.1.8 | ColumnubiModuleAction | read-write | current | This object, when read, returns one of the following results: other(1): module permanently enabled Setting this object to one of the acceptable values gives th… |
| 1.3.6.1.4.1.7800.100.3.1.3 | TableubiSlotTable | not-accessible | current | This table contains one row per slot entity. |
| 1.3.6.1.4.1.7800.100.3.1.3.1 | RowubiSlotEntry | not-accessible | current | Information about a particular slot entity. |
| 1.3.6.1.4.1.7800.100.3.1.3.1.1 | ColumnubiSlotModuleId | read-only | current | The unique module ID. |
| 1.3.6.1.4.1.7800.100.3.1.3.1.2 | ColumnubiSlotId | read-only | current | The unique slot ID. |
| 1.3.6.1.4.1.7800.100.3.1.3.1.3 | ColumnubiSlotType | read-only | current | The textual type of this slot. |
| 1.3.6.1.4.1.7800.100.3.1.3.1.4 | ColumnubiSlotOperStatus | read-only | current | The status of this slot. |
| 1.3.6.1.4.1.7800.100.3.1.3.1.5 | ColumnubiSlotPortNumber | read-only | current | This value is determined by the number of port where the slot is located. |
| 1.3.6.1.4.1.7800.100.3.1.3.1.6 | ColumnubiSlotSerialNumber | read-write | current | The serial number of this slot. |
| 1.3.6.1.4.1.7800.100.3.1.4 | NodeubiExtSlot | |||
| 1.3.6.1.4.1.7800.100.3.1.4.1 | ScalarubiIEEE1588SlotOperStatus | read-only | current | The operational status of the slot for IEEE 1588 specification. |
| 1.3.6.1.4.1.7800.100.3.1.4.2 | ScalarubiMngSlotOperStatus | read-only | current | The operational status of the slot for mng specification. |
| 1.3.6.1.4.1.7800.100.3.1.5 | NodeubiTransceiver | |||
| 1.3.6.1.4.1.7800.100.3.1.5.1 | TableubiEntitySensorTable | not-accessible | current | This table contains objects which provide information about the transceiver sensor of physical entity. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1 | RowubiEntitySensorEntry | not-accessible | current | An entry containing management information applicable to the transceiver sensor of a particular physical entity. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.1 | ColumnubiEntSensorType | read-only | current | This variable indicates the type of data reported by the entSensorValue. valid values are: other(1): a measure other than those listed below unknown(2): unknow… |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.2 | ColumnubiEntSensorScale | read-only | current | This variable indicates the exponent to apply to sensor values reported by entSensorValue. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.3 | ColumnubiEntSensorValue | read-only | current | This variable reports the most recent measurement seen by the sensor. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.4 | ColumnubiEntSensorEventStatus | read-only | current | This variable indicates the present current event status of the sensor. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.5 | ColumnubiEntSensorEventUpdateTime | read-only | current | The value of sysUpTime when the status of entity sensor is changed. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.6 | ColumnubiEntSensorAlarmHighThreshold | read-write | current | This variable indicates the value of the high alarm threshold. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.7 | ColumnubiEntSensorWarningHighThreshold | read-write | current | This variable indicates the value of the high warning threshold. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.8 | ColumnubiEntSensorWarningLowThreshold | read-write | current | This variable indicates the value of the low warning threshold. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.9 | ColumnubiEntSensorAlarmLowThreshold | read-write | current | This variable indicates the value of the low alarm threshold. |
| 1.3.6.1.4.1.7800.100.3.1.5.1.1.10 | ColumnubiEntSensorName | read-only | current | This variable indicates the name of the sensor entity. |
| 1.3.6.1.4.1.7800.100.3.1.5.2 | TableubiTransceiverInfoTable | not-accessible | current | This table contains objects which provide information about the transceiver of physical entity. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1 | RowubiTransceiverInfoEntry | not-accessible | current | An entry containing management information applicable to the transceiver of a particular physical entity. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.1 | ColumnubiTcIdentifier | read-only | current | This variable indicates the transceiver indentifier. valid value are: unknown(0), other(1), gbic(2), module(3), sfp(4), xbi(5), xenpak(6), xfp(7), xff(8), xfp_… |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.2 | ColumnubiTcVendorOUI | read-only | current | This variable indicates a textual string containing information about the IEEE company ID of transceiver vendor |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.3 | ColumnubiTcVendorName | read-only | current | A textual string containing information about the transceiver name. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.4 | ColumnubiTcVendorPartNumber | read-only | current | A textual string containing information about the part number of the transceiver. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.5 | ColumnubiTcVendorRevisionLevel | read-only | current | A textual string containing information about the revision level of the transceiver part number. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.6 | ColumnubiTcVendorSerialNumber | read-only | current | This variable indicates a textual string containing information about the transceiver serial number. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.7 | ColumnubiTcVendorManufacturingDate | read-only | current | This variable indicates a manufacturing date of transceiver |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.8 | ColumnubiTcWaveLength | read-only | current | This variable indicates a wave length of transceiver. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.9 | ColumnubiTcConnector | read-only | current | This variable indicates a connector type of transceiver. |
| 1.3.6.1.4.1.7800.100.3.1.5.2.1.10 | ColumnubiTcLength | read-only | current | This variable indicates a length of transceiver. |
| 1.3.6.1.4.1.7800.100.3.1.5.3 | ScalarubiTransceiverMonitoring | read-write | current | This variable indicates whether the system produces the log and notification for transceiver sensor. |
| 1.3.6.1.4.1.7800.100.3.2 | NodeubiEntityMIBNotificationPrefix | |||
| 1.3.6.1.4.1.7800.100.3.2.0 | NodeubiFruNotifications | |||
| 1.3.6.1.4.1.7800.100.3.2.0.1 | NotificationubiFRUInserted | current | The ubiEntityFRUInserted notification indicates that a FRU was inserted. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, … | |
| 1.3.6.1.4.1.7800.100.3.2.0.2 | NotificationubiFRURemoved | current | The ubiEntityFRURemoved notification indicates that a FRU was removed. The varbind for this notification indicates the entPhysicalIndex of the removed FRU, and… | |
| 1.3.6.1.4.1.7800.100.3.2.1 | NodeubiEntitySensorNotifications | |||
| 1.3.6.1.4.1.7800.100.3.2.1.1 | NotificationubiEntSensorThreshold | current | The ubiEntSensorThreshold notification indicates that the status of transceiver sensor was changed. | |
| 1.3.6.1.4.1.7800.100.3.3 | NodeubiEntityMIBConformance | |||
| 1.3.6.1.4.1.7800.100.3.3.1 | NodeubiEntityMIBCompliances | |||
| 1.3.6.1.4.1.7800.100.3.3.1.1 | ComplianceubiEntityMIBCompliance | current | An Entity-MIB implementation can implement this group to provide FRU status and control. | |
| 1.3.6.1.4.1.7800.100.3.3.2 | NodeubiEntityMIBGroups | |||
| 1.3.6.1.4.1.7800.100.3.3.2.1 | GroupubiEntityMIBModuleGroup | current | The collection of objects which are used to get the operational state and redundancy state of the modules | |
| 1.3.6.1.4.1.7800.100.3.3.2.2 | GroupubiEntitySlotGroup | current | The collection of objects which are used to get the operational state and redundancy state of the slot. | |
| 1.3.6.1.4.1.7800.100.3.3.2.3 | GroupubiEntityMIBNotificationGroup | current | TThe collection of objects which are used to send a notification. | |
| 1.3.6.1.4.1.7800.100.3.3.2.4 | GroupubiEntiryMIBIEEE1588SlotGroup | current | The collection of objects which are used to get the operational state of the slot for IEEE 1588. | |
| 1.3.6.1.4.1.7800.100.3.3.2.5 | GroupubiEntityMIBTransceiverGroup | current | The collection of objects which are used to get the information of transceiver. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| ModuleOperType | INTEGER { other(1), ok(2), disabled(3) } | current | Operational module states. Valid values are : unknown(1) Module is not in one of other states normal operational states: ok(2) Module is operational. disabled(3) Module is administratively disabled. selfTest(6) Module i… |
| UbiSensorDataScale | INTEGER { yocto(1), zepto(2), atto(3), femto(4), pico(5), nano(6), micro(7), milli(8), units(9), kilo(10), mega(11), giga(12), tera(13), exa(14), peta(15), zetta(16), yotta(17) } | current | International System of Units (SI) prefixes. |
| UbiSensorDataType | INTEGER { other(1), unknown(2), volts(3), amperes(4), celsius(5), dBm(6), percentRH(8), rpm(9), cmm(10), truthvalue(11), specialEnum(12), watts(13), hertz(14) } | current | sensor measurement data types. valid values are: other(1): a measure other than those listed below unknown(2): unknown measurement, or arbitrary, relative numbers volts(3): electric potential amperes(4): electric curren… |
| UbiSensorPrecision | INTEGER (-8..9) | current | When in the range 1 to 9, SensorPrecision is the number of decimal places in the fractional part of a SensorValue fixed-point number. When in the range -8 to -1, SensorPrecision is the number of accurate digits in a Sen… |
| UbiSensorValue | OCTET STRING | current | Represent the sensor value |
| UbiSensorValue_cisco | INTEGER (-1000000000..1000000000) | current | For sensors that measure voltsAC, voltsDC, amperes, watts, hertz, celsius, cmm this item is a fixed point number ranging from -999,999,999 to +999,999,999. Use the value -1000000000 to indicate underflow. Use the value … |
| UbiTcConnectorType | INTEGER { unknown(0), other(1), sc(2), fiber_style1_copper(3), fiber_stype2_copper(4), bnc_tnc(5), fiber_coaxial(6), fiberjack(7), lc(8), mt_rj(9), sg(10), optical_pigtail(11), hssdc2(12), copper_pigtail(13) } | current | |
| UbiTcEncodingType | INTEGER { unknown(0), other(1), enc_64b(2), enc_4b5b(3), enc_8b10b(4), enc_sonet(5), enc_nrz(6), enc_rz(7), enc_manchester(8) } | current | |
| UbiTcIdentifier | INTEGER { unknown(0), other(1), gbic(2), module(3), sfp(4), xbi(5), xenpak(6), xfp(7), xff(8), xfp_e(9), xpak(10), x2(11) } | current |