UTEPON4000CONF-MIB
123 objects
Contains UT EPON MIB Extensions.
Imported Objects
| BRIDGE-MIB | BridgeId MacAddress Timeout |
| IF-MIB | ifIndex InterfaceIndex InterfaceIndexOrZero |
| RFC1155-SMI | Counter TimeTicks |
| SNMPv2-SMI | IpAddress MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString PhysAddress RowStatus TEXTUAL-CONVENTION TruthValue |
| UTS-BBS-COMMON-MIB | utsGeponBBS4000 |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1949.1.3.10.200.6.2 | IdentityutsGeponBBS4000Configuration | Contains UT EPON MIB Extensions. | ||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1 | NodeutsSystemConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1 | NodeutsSystemExtObjects | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1 | TableutsEponModuleBoardTable | not-accessible | current | A list of board information in a EPON box. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1 | RowutsEponModuleBoardEntry | not-accessible | current | An entry contains board information on a module. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.1 | ColumnutsEponModuleBoardPhyId | read-only | current | The physical module number, 1-12 means service card, 13 means CSM A, 14 means CSM B. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.2 | ColumnutsEponModuleBoardType | read-only | current | The line card type. In bbs4000, current 4 kind board are supported: csm(2) epm04a(3) epm04b(4) epm04c(5) gem04(6) gem04a(8) |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.3 | ColumnutsEponModulePhyPresenceStat | read-only | current | The line card type. In EPON, BCM, OLT are supported |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.4 | ColumnutsEponModuleAdminState | read-write | current | administrative state changed by operator, locked(1) unlocked (2) reset(8) |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.5 | ColumnutsEponModuleOperationState | read-only | current | The internal state of line card |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.6 | ColumnutsEponModuleRedundancyState | read-only | current | The redundancy state of CSM module, for other line card, the unique state is other(1). |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.8 | ColumnutsEponModulePhyicalUptime | read-only | current | when the physical module is up. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.9 | ColumnutsEponOpStateUptime | read-only | current | when the oepration state of this module become active. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.11 | ColumnutsEponModuleCSMSwitchtime | read-only | current | when the oepration state of this module become active. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.12 | ColumnutsEponModuleBoardSwVer | read-only | current | Software version of the board. The software verion is applicable to the whole box and therefore belongs to the GSM board. For LTM boards, the this object retur… |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.13 | ColumnutsEponModuleBoardBootromVer | read-only | current | The Bootrom version of the board. The Bootrom verion is applicable to the whole box and therefore belongs to the GSM board. For LTM boards, the this object ret… |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.14 | ColumnutsEponModuleBoardPassaveVer | read-only | current | The Passave Olt Firmware revision for the LTM board. Each of the two LTM boards has a copy of the firmware running therefore both will show a firmware version.… |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.15 | ColumnutsEponModuleBoardCurTemp | read-only | current | The current temperature of physical slot. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.16 | ColumnutsEponModuleBoardTempUpLimit | read-write | current | The maximum threshold of physical slot temperature. The default value is 70. It is suggested this value shall be greater than up clear limit value for 5. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.17 | ColumnutsEponModuleBoardTempUpClearLimit | read-write | current | The up clear limit of physical slot temperature. The default value is 65. It is suggested this value shall be lower than up limit value for 5. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.18 | ColumnutsEponModuleBoardLastAdminStateChangetime | read-only | current | Last Administrative State Change Time Till Now (TimeTicks). |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.19 | ColumnutsEponModuleBoardLastOperationStateChangetime | read-only | current | Last Operational State Change Time Till Now (TimeTicks). |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.20 | ColumnutsEponModuleBoardDisableCause | read-only | current | The disable Cause. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.21 | ColumnutsEponModuleBoardHwVer | read-only | current | Hw version of the board |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.22 | ColumnutsEponModuleBoardCpldVer | read-only | current | CPLD version of the board |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.23 | ColumnutsEponModuleBoardSerialNumber | read-only | current | SN information of the board |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.24 | ColumnutsEponModuleBoard2424Information | read-only | current | 2424 information of the board |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.26 | ColumnutsEponModuleBoardHASyncStatus | read-only | current | The HA Sync status for the initial sync when the standby card insert. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.27 | ColumnutsEponModuleBoardCpuUtil | read-only | current | The current cpu util of the board, in the current system, only csm board should be readed, and the value should be from 0 to 1000. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.28 | ColumnutsEponModuleBoardMemUtil | read-only | current | The current memory util of the board, in the current system, only csm board should be readed, and the value should be from 0 to 1000. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4 | NodeutsManagementConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.1 | NodeutsSystemConfGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.1.1 | ScalarutsBBSVlanVPNTPID | read-write | current | bbs system vlan vpn tpid.The default value is 0x8100 |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.1.2 | ScalarutsBBSVlanVPNTunnel | read-write | current | bbs system vlan vpn tunnle enable/disable, the default value is disable. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.1.3 | ScalarutsBBSVlanVPNPRISource | read-only | current | The outer tag PRI source setting, the default value is customertag! |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.1.4 | ScalarutsBBSMaxFrameSize | read-write | current | Max receive frame size setting, all the frame size greater than it will be dropped. (Max-frame 64-16368). the default value 1518. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.2 | NodeutsFTPConfGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.3 | NodeutsFileSystemGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4 | NodeutsChassisConfGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.1 | ScalarutsBBSChassisPwrType | read-only | current | bbs power supply module type, AC or DC. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.2 | ScalarutsBBSChassisPwrLowSlot | read-only | current | whether the chassis power module in low slot exist and work normally |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.3 | ScalarutsBBSChassisPwrHighSlot | read-only | current | whether the chassis power module in high slot exist and work normally |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.4 | ScalarutsBBSChassisInternalPowerStat | read-only | current | chassis the system power module status, such as over voltage, low voltage, etc |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.5 | ScalarutsBBSChassisFanTrayStat | read-only | current | whether the chassis Fan tray module exist |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.8 | ScalarutsBBSChassisLeftFanTrayStat | read-only | current | The state of left fan. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.9 | ScalarutsBBSChassisMiddleFanTrayStat | read-only | current | The state of middle fan. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.4.10 | ScalarutsBBSChassisRightFanTrayStat | read-only | current | The state of right fan |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.5 | NodeutsTFTPConfGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6 | NodeutsLedMgmtConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1 | NodeutsLedCSMLedDispGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.1 | ScalarutsBBSLEDCSMAPowerLedState | read-only | current | bbs LED state display: CSM A power LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.2 | ScalarutsBBSLEDCSMAActiveLedState | read-only | current | bbs LED state display: CSM A Active LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.3 | ScalarutsBBSLEDCSMARunLedState | read-only | current | bbs LED state display: CSM A Run LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.4 | ScalarutsBBSLEDCSMACriticalAlarmLedState | read-only | current | bbs LED state display: CSM A Critical Alarm LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.5 | ScalarutsBBSLEDCSMAMajorAlarmLedState | read-only | current | bbs LED state display: CSM A Major Alarm LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.6 | ScalarutsBBSLEDCSMAMinorAlarmLedState | read-only | current | bbs LED state display: CSM A Minor Alarm LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.7 | ScalarutsBBSLEDCSMAHotSwapLedState | read-only | current | bbs LED state display: CSM A Hot Swap LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.8 | ScalarutsBBSLEDCSMAEmsPortLinkLedState | read-only | current | bbs LED state display: CSM A Ems Port Link LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.9 | ScalarutsBBSLEDCSMAEmsPortSpeedLedState | read-only | current | bbs LED state display: CSM A Ems Port Speed LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.10 | ScalarutsBBSLEDCSMBPowerLedState | read-only | current | bbs LED state display: CSM B power LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.11 | ScalarutsBBSLEDCSMBActiveLedState | read-only | current | bbs LED state display: CSM B Active LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.12 | ScalarutsBBSLEDCSMBRunLedState | read-only | current | bbs LED state display: CSM B Run LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.13 | ScalarutsBBSLEDCSMBCriticalAlarmLedState | read-only | current | bbs LED state display: CSM B Critical Alarm LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.14 | ScalarutsBBSLEDCSMBMajorAlarmLedState | read-only | current | bbs LED state display: CSM B Major Alarm LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.15 | ScalarutsBBSLEDCSMBMinorAlarmLedState | read-only | current | bbs LED state display: CSM B Minor Alarm LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.16 | ScalarutsBBSLEDCSMBHotSwapLedState | read-only | current | bbs LED state display: CSM B Hot Swap LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.17 | ScalarutsBBSLEDCSMBEmsPortLinkLedState | read-only | current | bbs LED state display: CSM B Ems Port Link LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.1.18 | ScalarutsBBSLEDCSMBEmsPortSpeedLedState | read-only | current | bbs LED state display: CSM B Ems Port Speed LED. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2 | NodeutsLedPonSlotLedDispObjs | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1 | TableutsLedPonSlotLedDispTable | not-accessible | current | bbs system PON slot LED state display table. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1 | RowutsLedPonSlotLedDispEntry | not-accessible | current | An entry containing led state information of a pon slot. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.1 | ColumnutsLedPonSlotLedDispSlotId | read-only | current | A read-only value that identifies the pon module slot id. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.2 | ColumnutsLedPonSlotLedDispPowLedStat | read-only | current | pon slot power supply LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.3 | ColumnutsLedPonSlotLedDispRunLedStat | read-only | current | pon slot run LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.4 | ColumnutsLedPonSlotLedDispFaultLedStat | read-only | current | pon slot fault LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.5 | ColumnutsLedPonSlotLedDispSwapLedStat | read-only | current | pon slot hot swap LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.6 | ColumnutsLedPonSlotLedDispPonPort1OprLedStat | read-only | current | pon slot pon port 1 Operation LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.7 | ColumnutsLedPonSlotLedDispPonPort1FaultLedStat | read-only | current | pon slot pon port 1 Fault LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.8 | ColumnutsLedPonSlotLedDispPonPort2OprLedStat | read-only | current | pon slot pon port 2 Operation LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.9 | ColumnutsLedPonSlotLedDispPonPort2FaultLedStat | read-only | current | pon slot pon port 2 Fault LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.10 | ColumnutsLedPonSlotLedDispPonPort3OprLedStat | read-only | current | pon slot pon port 3 Operation LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.11 | ColumnutsLedPonSlotLedDispPonPort3FaultLedStat | read-only | current | pon slot pon port 3 Fault LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.12 | ColumnutsLedPonSlotLedDispPonPort4OprLedStat | read-only | current | pon slot pon port 4 Operation LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.2.1.1.13 | ColumnutsLedPonSlotLedDispPonPort4FaultLedStat | read-only | current | pon slot pon port 4 Fault LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3 | NodeutsLedGEPortSlotLedDispObjs | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1 | TableutsLedGEPortSlotLedDispTable | not-accessible | current | bbs system GE Port slot LED state display table. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1 | RowutsLedGEPortSlotLedDispEntry | not-accessible | current | An entry containing led state information of a GE port slot. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.1 | ColumnutsLedGEPortSlotLedDispSlotId | read-only | current | A read-only value that identifies the GE module slot id. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.2 | ColumnutsLedGEPortSlotLedDispPowLedStat | read-only | current | GE port slot power supply LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.3 | ColumnutsLedGEPortSlotLedDispRunLedStat | read-only | current | GE port slot run LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.4 | ColumnutsLedGEPortSlotLedDispFaultLedStat | read-only | current | GE port slot fault LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.5 | ColumnutsLedGEPortSlotLedDispSwapLedStat | read-only | current | GE port slot hot swap LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.6 | ColumnutsLedGEPortSlotLedDispPort1LinkLedStat | read-only | current | GE slot GE port 1 Link LED state,if the board type is xgm01a,then use this item only. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.8 | ColumnutsLedGEPortSlotLedDispPort2LinkLedStat | read-only | current | GE slot GE port 2 Link LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.10 | ColumnutsLedGEPortSlotLedDispPort3LinkLedStat | read-only | current | GE slot GE port 3 Link LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.6.3.1.1.12 | ColumnutsLedGEPortSlotLedDispPort4LinkLedStat | read-only | current | GE slot GE port 4 Link LED state. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8 | NodeutsHAMgmtConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8.1 | NodeutsHAMgmtConfObjs | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8.1.1 | NodeutsHAMgmtConfGroup | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8.1.1.1 | ScalarutsHAMgmtManualSwitchOver | read-write | current | HA management manual force switch over |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8.1.1.2 | ScalarutsHAMgmtRebootWholeSystem | read-write | current | HA management reboot whole system |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8.1.1.3 | ScalarutsHAMgmtMasterBoardBootFileName | read-write | current | bbs system boot image file name with path for master board |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.4.8.1.1.4 | ScalarutsHAMgmtSlaveBoardBootFileName | read-write | current | bbs system boot image file name with path for slave board |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.1.2 | NodeeponOamInitAlm | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2 | NodeutsEthIfConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1 | NodeutsEthIfExtObjects | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5 | NodeutsLayer2ConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3 | NodeutsMonitorSessionObjects | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1 | TableutsMonitorSessionControlTable | not-accessible | current | Table for monitor session MIB objects. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1 | RowutsMonitorSessionControlEntry | not-accessible | current | An entry in the monitor session control MIB table. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.1 | ColumnutsMonitorSessionID | read-create | current | Monitor session ID. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.2 | ColumnutsMonitorSessionModule | read-write | current | Monitor session control module number. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.3 | ColumnutsMonitorSessionPort | read-write | current | Monitor session control port umber. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.4 | ColumnutsMonitorSessionIngressPortBitLists | read-write | current | Monitor session control ingress port bit lists . |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.5 | ColumnutsMonitorSessionEngressPortBitLists | read-write | current | Monitor session control ingress port bit lists . |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.6 | ColumnutsMonitorSessionActive | read-write | current | Monitor session enable or disable. |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.2.1.5.3.1.1.7 | ColumnutsMonitorSessionRowStatus | read-create | current | Row status |
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.3 | NodeutsEfmPonConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.4 | NodeutsServiceConfExt | |||
| 1.3.6.1.4.1.1949.1.3.10.200.6.2.4.2 | NodeutsAclExt |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| UtsConfStationIdType | DisplayString(SIZE(0..16)) | current | The station Id to identify the issued configuration command |
| UtsConfStatusType | INTEGER { success(1), failure(2), busy(3) } | current | Confiuration/Test command result. |
| UtsSyslogServerityLevelType | INTEGER { emergencies(1), alerts(2), critical(3), errors(4), warnings(5), notifications(6), informational(7), debugging(8) } | current | The Syslog serverity types used by UT's BBS1000 SyslogServerTable. |