MIB Viewer

VIDEOFRAME-SIGMON-VM0006-MIB

20 objects
This MIB describes the device specific objects of the VM0006 GPI Interface Module, and augments MIB-2, VF-GENERIC, and VF-SIGMON in the identification of this Videoframe Systems managed device. This module will be extended or modified as required. Videoframe Systems reserves the right to make changes in specification and other information contained in this document without prior notice. The reader should consult Videoframe Systems to determine whether any such changes have been made. In no event shall Videoframe Systems be liable for any incidental, indirect, special, or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this document or the information contained in it. Videoframe Systems grants vendors, end users, and other interested parties a non-exclusive license to use this specification in connection with the management of Videoframe Systems products. Copyright 2001 Videoframe, Inc.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4596.4.2.1.6Nodevm0006GPIInterface
1.3.6.1.4.1.4596.4.2.1.6.1Tablevm0006Tablenot-accessiblecurrentEach row contains information about one VM0006 GPI Interface module in the managed VF200 frame.
1.3.6.1.4.1.4596.4.2.1.6.1.1Rowvm0006Entrynot-accessiblecurrentA GPI Interface module entry.
1.3.6.1.4.1.4596.4.2.1.6.1.1.1Columnvm0006SlotNumberread-onlycurrentThe slot that this entry represents.
1.3.6.1.4.1.4596.4.2.1.6.1.1.2Columnvm0006Activeread-onlycurrentIndicates whether this entry is active (this module is in this slot).
1.3.6.1.4.1.4596.4.2.1.6.1.1.3Columnvm0006Locateread-writecurrentControls the locate indicator on the module and indicates its current state. Set to flash (1) to cause the locate LED on the front of the module to begin flash…
1.3.6.1.4.1.4596.4.2.1.6.2Tablevm0006GPISignalTablenot-accessiblecurrentEach row contains information about one GPI signal of one VM0006 GPI Interface module in the managed VF200 frame.
1.3.6.1.4.1.4596.4.2.1.6.2.1Rowvm0006GPISignalEntrynot-accessiblecurrentA GPI Interface module GPI signal entry.
1.3.6.1.4.1.4596.4.2.1.6.2.1.1Columnvm0006GPISignalSlotNumberread-onlycurrentThe frame slot number that this entry represents.
1.3.6.1.4.1.4596.4.2.1.6.2.1.2Columnvm0006GPISignalNumberread-onlycurrentThe GPI number within the module.
1.3.6.1.4.1.4596.4.2.1.6.2.1.3Columnvm0006GPISignalStateread-onlycurrentIndicates the current state of this GPI signal.
1.3.6.1.4.1.4596.4.2.1.6.2.1.4Columnvm0007GPIChandedAckread-writecurrentWhen Auto Re-Arm is set to off, set to acknowledge (3) to acknowledge a triggered gpiChanged notification.
1.3.6.1.4.1.4596.4.2.1.6.2.1.5Columnvm0006GPISignalNameread-writecurrentThe name of this GPI signal.
1.3.6.1.4.1.4596.4.2.1.6.2.1.6Columnvm0006GPISignalDescriptionread-writecurrentDescriptive identification of this GPI signal.
1.3.6.1.4.1.4596.4.2.1.6.2.1.7Columnvm0006GPISignalTrapEnableread-writecurrentEnables or disables trap generation from this GPI signal.
1.3.6.1.4.1.4596.4.2.1.6.3Nodevm0006GPIInterfaceEvents
1.3.6.1.4.1.4596.4.2.1.6.3.0Nodevm0006GPIInterfaceEventsV2
1.3.6.1.4.1.4596.4.2.1.6.3.0.1NotificationgpiChangedcurrentOne or more GPIs, for which traps are enabled, has changed state.
1.3.6.1.4.1.4596.6.1.6IdentityvideoframeSigmonVm0006MIBThis MIB describes the device specific objects of the VM0006 GPI Interface Module, and augments MIB-2, VF-GENERIC, and VF-SIGMON in the identification of this …
1.3.6.1.4.1.4596.6.2.5.6IdentityvfProductsVM0006currentVideoframe VM0006 GPO Interface (Relay) Module.