MIB Viewer

Wellfleet-FR-MIB

50 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.18.3.5.9.1.1TablewfFrDlcmiTablenot-accessiblemandatoryThe Parameters for the Data Link Connection Management Interface
1.3.6.1.4.1.18.3.5.9.1.1.1RowwfFrDlcmiEntrynot-accessiblemandatoryThe parameters for a particular Data Link Connection Management Interface
1.3.6.1.4.1.18.3.5.9.1.1.1.1ColumnwfFr1DlcmiDeleteread-writemandatoryIndication to delete this frame relay interface
1.3.6.1.4.1.18.3.5.9.1.1.1.2ColumnwfFr1DlcmiDisableread-writemandatoryIndicates when a dlcmi entry is to be enabled or disabled.
1.3.6.1.4.1.18.3.5.9.1.1.1.3ColumnwfFr1DlcmiStateread-onlymandatoryThe current state of Frame Relay. The not present state is not actually valid except when the record is first added. It is included for consistency.
1.3.6.1.4.1.18.3.5.9.1.1.1.4ColumnwfFr1DlcmiCircuitread-onlymandatoryInstance identifier. The circuit number of this entry
1.3.6.1.4.1.18.3.5.9.1.1.1.5ColumnwfFr1DlcmiManagementTyperead-writemandatoryThis variable indicates which Data Link Connection Management scheme is active (and by implication, what DLCI it uses).
1.3.6.1.4.1.18.3.5.9.1.1.1.6ColumnwfFr1DlcmiStatusread-onlymandatoryIndicates the status of the interface. FR1_STATUS_START is the state during rebooting or initial start of circuit FR1_STATUS_RUNNING1 is the sate after the cir…
1.3.6.1.4.1.18.3.5.9.1.1.1.7ColumnwfFr1DlcmiAddressread-writemandatoryThis states which address format is in use on the FR interface. The default is Q922
1.3.6.1.4.1.18.3.5.9.1.1.1.8ColumnwfFr1DlcmiAddressLenread-writemandatoryThis variable states the address length in octets. In the case of Q922 format, the length indicates the entire length of the address includeding the control po…
1.3.6.1.4.1.18.3.5.9.1.1.1.9ColumnwfFr1DlcmiPollingIntervalread-writemandatoryThe number of seconds between successive status enquiry messages
1.3.6.1.4.1.18.3.5.9.1.1.1.10ColumnwfFr1DlcmiFullEnquiryIntervalread-writemandatoryThe number of status enquiry intervals that pass before issuance of a full status enquiry message.
1.3.6.1.4.1.18.3.5.9.1.1.1.11ColumnwfFr1DlcmiErrorThresholdread-writemandatoryThis is the maximum number of unanswered Status Enquiries the equipment shall accept before declaring the interface down.
1.3.6.1.4.1.18.3.5.9.1.1.1.12ColumnwfFr1DlcmiMonitoredEventsread-writemandatoryThis is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station…
1.3.6.1.4.1.18.3.5.9.1.1.1.13ColumnwfFr1DlcmiMaxSupportedVCsread-onlymandatoryThe maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network. The system sets this initially.
1.3.6.1.4.1.18.3.5.9.1.1.1.14ColumnwfFr1DlcmiMulticastread-writemandatoryThis indicates whether the frame relay provider offers a multicast
1.3.6.1.4.1.18.3.5.9.1.1.1.15ColumnwfFr1DlcmiSeqCountread-onlymandatoryThis station's sequence counter. It represents the next value to send.
1.3.6.1.4.1.18.3.5.9.1.1.1.16ColumnwfFr1DlcmiLastReceivedread-onlymandatoryThe sequence number just received from the switch.
1.3.6.1.4.1.18.3.5.9.1.1.1.17ColumnwfFr1DlcmiPassiveSeqCountread-onlymandatoryThis station's sequence counter for answering status enquiry.
1.3.6.1.4.1.18.3.5.9.1.1.1.18ColumnwfFr1DlcmiPassiveReceivedread-onlymandatoryThe sequence number just received from the enquring station.
1.3.6.1.4.1.18.3.5.9.1.1.1.19ColumnwfFr1DlcmiPollsread-onlymandatoryThis is the counter of where we are in the polling cycle.
1.3.6.1.4.1.18.3.5.9.1.1.1.20ColumnwfFr1DlcmiAlarmTimerread-onlymandatoryThis is a counter of 1/2 second timeouts. When it reaches 2 x the polling interval, an enquiry message is sent.
1.3.6.1.4.1.18.3.5.9.1.1.1.21ColumnwfFr1ErrTyperead-onlymandatoryIndicate the type of the last specific monitored error.
1.3.6.1.4.1.18.3.5.9.1.1.1.22ColumnwfFr1ErrDataread-onlymandatoryContains as much of the error packet as possible.
1.3.6.1.4.1.18.3.5.9.1.1.1.23ColumnwfFr1ErrTimeread-onlymandatoryThe time the last error occurred.
1.3.6.1.4.1.18.3.5.9.1.1.1.24ColumnwfFr1ErrDiscardsread-onlymandatoryThe number of inbound frames dropped because of format or other errors or because the VC was not known.
1.3.6.1.4.1.18.3.5.9.1.1.1.25ColumnwfFr1ErrDropsread-onlymandatoryThe number of outbound frames dropped. Usually this is due the specified DLCI being unknown or a broadcast packet is too long
1.3.6.1.4.1.18.3.5.9.1.2TablewfFrCircuitTablenot-accessiblemandatoryFrame Relay Circuit table gives information about a virtual circuits.
1.3.6.1.4.1.18.3.5.9.1.2.1RowwfFrCircuitEntrynot-accessiblemandatoryAn entry in the Frame Relay Circuit table.
1.3.6.1.4.1.18.3.5.9.1.2.1.1ColumnwfFr1CircuitDeleteread-writemandatoryIndication to delete this frame relay interface.
1.3.6.1.4.1.18.3.5.9.1.2.1.2ColumnwfFr1CircuitNumberread-onlymandatoryInstance identifier. The circuit number of this interface.
1.3.6.1.4.1.18.3.5.9.1.2.1.3ColumnwfFr1CircuitDlciread-onlymandatoryInstance identifier. This indicates which virtual circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.4ColumnwfFr1CircuitStateread-onlymandatoryIndicates the state of the particular virtual circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.5ColumnwfFr1CircuitStateSetread-writemandatoryUser access for setting the state of a virtual circuit
1.3.6.1.4.1.18.3.5.9.1.2.1.6ColumnwfFr1CircuitReceivedFECNsread-onlymandatoryNumber of frames received indicating forward congestion.
1.3.6.1.4.1.18.3.5.9.1.2.1.7ColumnwfFr1CircuitReceivedBECNsread-onlymandatoryNumber of frames received indicating backward congestion.
1.3.6.1.4.1.18.3.5.9.1.2.1.8ColumnwfFr1CircuitSentFramesread-onlymandatoryThe number of frames sent from this virtual circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.9ColumnwfFr1CircuitSentOctetsread-onlymandatoryThe number of octets sent from this virtual circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.10ColumnwfFr1CircuitReceivedFramesread-onlymandatoryThe number of frames received from this virtual circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.11ColumnwfFr1CircuitReceivedOctetsread-onlymandatoryThe number of octets received from this virtual circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.12ColumnwfFr1CircuitCreationTimeread-onlymandatoryThe value of sysUpTime when the vc was created.
1.3.6.1.4.1.18.3.5.9.1.2.1.13ColumnwfFr1CircuitLastTimeChangeread-onlymandatoryThe value of sysUpTime when last there was a change in vc state.
1.3.6.1.4.1.18.3.5.9.1.2.1.14ColumnwfFr1CircuitCommittedBurstread-writemandatoryIndicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval. Wellfleet does not…
1.3.6.1.4.1.18.3.5.9.1.2.1.15ColumnwfFr1CircuitExcessBurstread-writemandatoryIndicates teh maximum amount of uncommitted data bits that the network will attempt to deliver over the measurement interval. Wellfleet does not presently supp…
1.3.6.1.4.1.18.3.5.9.1.2.1.16ColumnwfFr1CircuitThroughputread-writemandatoryThis is the average number of 'Frame Relay Information Field' bits transferred per second across a user network interface in one direction, measured over the m…
1.3.6.1.4.1.18.3.5.9.1.2.1.17ColumnwfFr1CircuitMulticastread-writemandatoryIndicates whether this DLCI is used for multicast or single destination.
1.3.6.1.4.1.18.3.5.9.1.2.1.18ColumnwfFr1CircuitDiscardsread-onlymandatoryThe number of inbound frames discarded because of format errors, because the VC is inactive or because the protocol was not registered for this circuit.
1.3.6.1.4.1.18.3.5.9.1.2.1.19ColumnwfFr1CircuitDropsread-onlymandatoryIndicates how many outbound frames were dropped. Usually these are dropped because the VC is not active.
1.3.6.1.4.1.18.3.5.9.1.2.1.20ColumnwfFr1CircuitSubCctread-writemandatoryCircuit number to use for this VC when configured in hybrid (for bridging) or direct access (VC as a circuit) mode.
1.3.6.1.4.1.18.3.5.9.1.2.1.21ColumnwfFr1CircuitModeread-writemandatoryThe mode of the given VC. GROUP - treats the VC as one of many vc's on a circuit. HYBRID - treats the VC as one of many vc's on a circuit for protocol traffic,…