| 1.3.6.1.4.1.15.2.3.1 | ScalartotalPorts | read-only | mandatory | The number of serial ports on this Annex. |
| 1.3.6.1.4.1.15.2.3.2 | ScalartotalInChars | read-only | mandatory | The total number of characters received on all serial ports. |
| 1.3.6.1.4.1.15.2.3.3 | ScalartotalOutChars | read-only | mandatory | The total number of characters transmitted on all serial ports. |
| 1.3.6.1.4.1.15.2.3.4 | ScalartotalParityErrs | read-only | mandatory | The total number of parity errors detected on all serial ports. |
| 1.3.6.1.4.1.15.2.3.5 | ScalartotalOverrunErrs | read-only | mandatory | The total number of overruns detected on all serial ports. |
| 1.3.6.1.4.1.15.2.3.6 | ScalartotalFramingErrs | read-only | mandatory | The total number of framing errors detected on all serial ports. |
| 1.3.6.1.4.1.15.2.3.7 | TableportTable | not-accessible | mandatory | Table of port entries. |
| 1.3.6.1.4.1.15.2.3.7.1 | RowportEntry | not-accessible | mandatory | The port's configuration parameters. |
| 1.3.6.1.4.1.15.2.3.7.1.1 | ColumnanxpPortIndex | read-only | mandatory | A unique number from 1 to totalPorts that identifies each serial port. |
| 1.3.6.1.4.1.15.2.3.7.1.2 | ColumnanxpMode | read-write | mandatory | This parameter defines the mode for access to the serial line port. The default is cli. This MIB object corresponds to the NA/admin asynchronous port parameter… |
| 1.3.6.1.4.1.15.2.3.7.1.3 | ColumnanxpCtrlLines | read-write | mandatory | The type of hardware control used on the port: none, modem control (dcd/dtr), flow control (cts/rts), or both. This MIB object corresponds to the NA/admin asyn… |
| 1.3.6.1.4.1.15.2.3.7.1.4 | ColumnanxpBidirModem | read-write | mandatory | This parameter controls whether the port is configured for adaptive use with a bidirectional modem. This MIB object corresponds to the NA/admin asynchronous po… |
| 1.3.6.1.4.1.15.2.3.7.1.5 | ColumnanxpAllowBcast | read-write | mandatory | Controls whether the serial port can receive administrative broadcast messages. This MIB object corresponds to the NA/admin asynchronous port parameter 'allow_… |
| 1.3.6.1.4.1.15.2.3.7.1.6 | ColumnanxpBcastDirection | read-write | mandatory | Defines the direction that an administrative broadcast message is sent. This parameter is valid only when the port is defined as a slave port by the anxpMode p… |
| 1.3.6.1.4.1.15.2.3.7.1.7 | ColumnanxpInputStartChar | read-write | mandatory | The control character sequence that restarts input if the charPortInFlowType parameter (in the char MIB) is set to xonXoff. This value of this object can be ei… |
| 1.3.6.1.4.1.15.2.3.7.1.8 | ColumnanxpInputStopChar | read-write | mandatory | The control character sequence that stops input if the charPortInFlowType parameter (in the char MIB) is set to xonXoff. This value of this object can be eithe… |
| 1.3.6.1.4.1.15.2.3.7.1.9 | ColumnanxpOutputStartChar | read-write | mandatory | The control character sequence that restarts output if the charPortOutFlowType parameter (in the char MIB) is set to xonXoff. This value of this object can be … |
| 1.3.6.1.4.1.15.2.3.7.1.10 | ColumnanxpOutputStopChar | read-write | mandatory | The control character sequence that stops output if the charPortOutFlowType parameter (in the char MIB) is set to xonXoff. This value of this object can be eit… |
| 1.3.6.1.4.1.15.2.3.7.1.11 | ColumnanxpIxanyFlowCtl | read-write | mandatory | This parameter specifies whether any input character will be treated as a start (xon) character when output has been suspended by a stop (xoff) character. This… |
| 1.3.6.1.4.1.15.2.3.7.1.12 | ColumnanxpLongBreak | read-write | mandatory | This parameter controls whether the Annex returns the user to the CLI prompt after receiving a break greater than two seconds. This MIB object corresponds to t… |
| 1.3.6.1.4.1.15.2.3.7.1.13 | ColumnanxpShortBreak | read-write | mandatory | This parameter controls whether the Annex returns the user to the CLI prompt after receiving a break shorter than two seconds. This MIB object corresponds to t… |
| 1.3.6.1.4.1.15.2.3.7.1.14 | ColumnanxpForwardTimer | read-write | mandatory | This parameter defines the inter-character timer that sets the amount of time, in tens of milliseconds, that will elapse before forwarding the received data. T… |
| 1.3.6.1.4.1.15.2.3.7.1.15 | ColumnanxpForwardCount | read-write | mandatory | Specifies the number of received characters buffered for the port by the Annex before forwarding the characters to the host or network. This MIB object corresp… |
| 1.3.6.1.4.1.15.2.3.7.1.16 | ColumnanxpImask7Bits | read-write | mandatory | When enabled, instructs the Annex to ignore the eighth bit of all received characters on the port. This MIB object corresponds to the NA/admin asynchronous por… |
| 1.3.6.1.4.1.15.2.3.7.1.17 | ColumnanxpAttnChar | read-write | mandatory | Defines a control character sequence as an attention character to return the user to the CLI prompt. The Annex-II only allows a single control character (eg. ^… |
| 1.3.6.1.4.1.15.2.3.7.1.18 | ColumnanxpInputBufSize | read-write | mandatory | The number of 256-byte blocks allocated to receive input characters from this port. This MIB object corresponds to the NA/admin asynchronous port parameter 'in… |
| 1.3.6.1.4.1.15.2.3.7.1.19 | ColumnanxpInputIsActivity | read-write | mandatory | Controls whether received input characters are considered as activity for the port. This MIB object corresponds to the NA/admin asynchronous port parameter 'in… |
| 1.3.6.1.4.1.15.2.3.7.1.20 | ColumnanxpOutputIsActivity | read-write | mandatory | Controls whether transmitted output characters are considered as activity for the port. This MIB object corresponds to the NA/admin asynchronous port parameter… |
| 1.3.6.1.4.1.15.2.3.7.1.21 | ColumnanxpInactivityTimer | read-write | mandatory | The amount of time, in minutes, which a port can remain inactive before the Annex terminates all sessions and resets the port. A value of 0 disables the timer.… |
| 1.3.6.1.4.1.15.2.3.7.1.22 | ColumnanxpResetIdleTimer | read-write | mandatory | Defines whether input or output resets the idle timer for the port. This MIB object corresponds to the NA/admin asynchronous port parameter 'reset_idle_time_on… |
| 1.3.6.1.4.1.15.2.3.7.1.23 | ColumnanxpCliInactivity | read-write | mandatory | The amount of time, in minutes, that the Annex waits before hanging up the serial port after it becomes idle. A value of 0 turns off the timer. A value of 255 … |
| 1.3.6.1.4.1.15.2.3.7.1.24 | ColumnanxpCliSecurity | read-write | mandatory | This parameter controls whether security is enabled for the port. This MIB object corresponds to the NA/admin asynchronous port parameter 'cli_security'. |
| 1.3.6.1.4.1.15.2.3.7.1.25 | ColumnanxpConnectSecurity | read-write | mandatory | This parameter controls whether the host-based security policy is enabled for access from the port to the network. This MIB object corresponds to the NA/admin … |
| 1.3.6.1.4.1.15.2.3.7.1.26 | ColumnanxpPortServerSecurity | read-write | mandatory | This parameter controls whether the host-based security policy is enabled for access to the port from the port server. This MIB object corresponds to the NA/ad… |
| 1.3.6.1.4.1.15.2.3.7.1.27 | ColumnanxpPortPassword | read-write | mandatory | This parameter defines a password for the port for local password protection. This MIB object corresponds to the NA/admin asynchronous port parameter 'port_pas… |
| 1.3.6.1.4.1.15.2.3.7.1.28 | ColumnanxpUserName | read-write | mandatory | A string defining the default user name for the user of this serial port. This MIB object corresponds to the NA/admin asynchronous port parameter 'user_name'. |
| 1.3.6.1.4.1.15.2.3.7.1.29 | ColumnanxpDedicatedAddr | read-write | mandatory | When the anxpMode parameter is set to dedicated, this parameter defines the Internet address of the host to which this port can connect to. This MIB object cor… |
| 1.3.6.1.4.1.15.2.3.7.1.30 | ColumnanxpDedicatedPort | read-write | mandatory | The application name or TCP port number to which this port can connect when the anxpMode parameter is set to dedicated. The allowed application names are 'teln… |
| 1.3.6.1.4.1.15.2.3.7.1.31 | ColumnanxpPrompt | read-write | mandatory | This parameter defines a port-specific prompt string. The prompt string consists of displayable characters and embedded formatting codes. Each formatting code … |
| 1.3.6.1.4.1.15.2.3.7.1.32 | ColumnanxpTermVar | read-write | mandatory | A string defining the type of terminal attached to the serial port. This MIB object corresponds to the NA/admin asynchronous port parameter 'term_var'. |
| 1.3.6.1.4.1.15.2.3.7.1.33 | ColumnanxpNewLineTerm | read-write | mandatory | This parameter controls whether a carriage return is echoed as just a carriage return (enabled), or whether the carriage return is echoed as a carriage return … |
| 1.3.6.1.4.1.15.2.3.7.1.34 | ColumnanxpEcho | read-write | mandatory | This parameter controls whether the Annex echoes all characters as they are received from the port. This MIB object corresponds to the NA/admin asynchronous po… |
| 1.3.6.1.4.1.15.2.3.7.1.35 | ColumnanxpMapToLower | read-write | mandatory | When enabled, the Annex translates all upper case characters to lower case as they are received from the port. This MIB object corresponds to the NA/admin asyn… |
| 1.3.6.1.4.1.15.2.3.7.1.36 | ColumnanxpMapToUpper | read-write | mandatory | When enabled, the Annex translates all lower case characters to upper case as they are transmitted to the port. This MIB object corresponds to the NA/admin asy… |
| 1.3.6.1.4.1.15.2.3.7.1.37 | ColumnanxpHardwareTabs | read-write | mandatory | When enabled, this parameter allows the Annex to expand ASCII tab characters. This MIB object corresponds to the NA/admin asynchronous port parameter 'hardware… |
| 1.3.6.1.4.1.15.2.3.7.1.38 | ColumnanxpCharErase | read-write | mandatory | This parameter controls whether the Annex echoes the character erase and word erase characters for a video terminal (enabled) or for a hard-copy terminal (disa… |
| 1.3.6.1.4.1.15.2.3.7.1.39 | ColumnanxpLineErase | read-write | mandatory | This parameter controls whether the Annex echoes the line erase character for a video terminal (enabled) or for a hard-copy terminal (disabled). This MIB objec… |
| 1.3.6.1.4.1.15.2.3.7.1.40 | ColumnanxpEraseChar | read-write | mandatory | Defines the character erase control character sequence. This value of this object can be either a single displayable character or two characters of the form '^… |
| 1.3.6.1.4.1.15.2.3.7.1.41 | ColumnanxpEraseWord | read-write | mandatory | Defines the word erase control character sequence. This value of this object can be either a single displayable character or two characters of the form '^x', w… |
| 1.3.6.1.4.1.15.2.3.7.1.42 | ColumnanxpEraseLine | read-write | mandatory | Defines the line erase control character sequence. This value of this object can be either a single displayable character or two characters of the form '^x', w… |
| 1.3.6.1.4.1.15.2.3.7.1.43 | ColumnanxpRedisplayLine | read-write | mandatory | Defines the reprint line control character sequence. This value of this object can be either a single displayable character or two characters of the form '^x',… |
| 1.3.6.1.4.1.15.2.3.7.1.44 | ColumnanxpToggleOutput | read-write | mandatory | Defines the flush control character used to flush the output buffer. This value of this object can be either a single displayable character or two characters o… |
| 1.3.6.1.4.1.15.2.3.7.1.45 | ColumnanxpTelnetEscape | read-write | mandatory | Defines the control character that returns the user to the 'telnet:' prompt when running the CLI telnet command. This value of this object can be either a sing… |
| 1.3.6.1.4.1.15.2.3.7.1.46 | ColumnanxpNeedDsr | read-write | mandatory | Specifies whether the DSR signal needs to be asserted when connecting to a slave port. This MIB object corresponds to the NA/admin asynchronous port parameter … |
| 1.3.6.1.4.1.15.2.3.7.1.47 | ColumnanxpTelnetCRLF | read-write | mandatory | Defines what characters are transmitted out the port to the network when the End-of-Line character is sensed. 'enabled' means transmit Line-Feed and Carriage-R… |
| 1.3.6.1.4.1.15.2.3.7.1.48 | ColumnanxpLatbEnable | read-write | mandatory | Controls interpretation of LAT Data-B packets received from host. This MIB object corresponds to the NA/admin asynchronous port parameter 'latb_enable'. |
| 1.3.6.1.4.1.15.2.3.7.1.49 | ColumnanxpSlipSecure | read-write | mandatory | If anxEnableSecurity is not set, this parameter selects slip session logging. If anxEnableSecurity is set, this parameter permits slip access only from secure … |
| 1.3.6.1.4.1.15.2.3.7.1.50 | ColumnanxpNetLocalAddr | read-write | mandatory | The Internet address for the Annex's side of the point-to-point (SLIP or PPP) link. This MIB object corresponds to the NA/admin asynchronous port parameter 'lo… |
| 1.3.6.1.4.1.15.2.3.7.1.51 | ColumnanxpNetRemoteAddr | read-write | mandatory | The Internet address for the host at the remote end of the point-to-point (SLIP or PPP) link. This MIB object corresponds to the NA/admin asynchronous port par… |
| 1.3.6.1.4.1.15.2.3.7.1.52 | ColumnanxpSlipSubnetMask | read-write | mandatory | The subnet mask for this SLIP interface. This MIB object corresponds to the NA/admin asynchronous port parameter 'subnet_mask'. |
| 1.3.6.1.4.1.15.2.3.7.1.53 | ColumnanxpSlipLoadDumpHost | read-write | mandatory | The Internet address of the host from which the Annex receives a load or to which the Annex sends a dump over the SLIP interface. This MIB object corresponds t… |
| 1.3.6.1.4.1.15.2.3.7.1.54 | ColumnanxpNetMetric | read-write | mandatory | This parameter defines the hop count to the remote end of the SLIP or PPP interface. Setting this object to 0 defaults to a value of 1. This MIB object corresp… |
| 1.3.6.1.4.1.15.2.3.7.1.55 | ColumnanxpSlipAllowDump | read-write | mandatory | This parameter defines whether the Annex is allowed to dump across a SLIP link. This MIB object corresponds to the NA/admin asynchronous port parameter 'slip_a… |
| 1.3.6.1.4.1.15.2.3.7.1.56 | ColumnanxpDoCompression | read-write | mandatory | When enabled, the Annex will attempt to negotiate TCP/IP header compression on this serial link. This MIB object corresponds to the NA/admin asynchronous port … |
| 1.3.6.1.4.1.15.2.3.7.1.57 | ColumnanxpAllowCompression | read-write | mandatory | When enabled, the Annex will allow TCP/IP header compression on this serial link only if the other end of the serial link initiates the compression. This MIB o… |
| 1.3.6.1.4.1.15.2.3.7.1.58 | ColumnanxpSlipMtuSize | read-write | mandatory | Force the compressed SLIP interface to use a Maximum Transmission Unit (MTU) of either 1024 bytes (large) or 256 bytes (small). The default is large. This MIB … |
| 1.3.6.1.4.1.15.2.3.7.1.59 | ColumnanxpSlipNoIcmp | read-write | mandatory | When enabled, the Annex will discard any ICMP packets directed to this SLIP link. This MIB object corresponds to the NA/admin asynchronous port parameter 'slip… |
| 1.3.6.1.4.1.15.2.3.7.1.60 | ColumnanxpSlipTos | read-write | mandatory | When enabled, the Annex sends interactive traffic over this SLIP link before any other traffic. This MIB object corresponds to the NA/admin asynchronous port p… |
| 1.3.6.1.4.1.15.2.3.7.1.61 | ColumnanxpPppMru | read-write | mandatory | This parameter defines the maximum receive unit in bytes. The default value is 1500. This MIB object corresponds to the NA/admin asynchronous port parameter 'p… |
| 1.3.6.1.4.1.15.2.3.7.1.62 | ColumnanxpPppAcm | read-write | mandatory | This parameter specifies which of the first 32 bytes (0x00, ... 0x1F) can be sent as clear text and which need to be escaped. A bit on in the mask indicates th… |
| 1.3.6.1.4.1.15.2.3.7.1.63 | ColumnanxpPppSecurityProto | read-write | mandatory | Defines which security protocol will be used to authenticate the remote user. This parameter must be set and the Annex enable_security (anxEnableSecurity) must… |
| 1.3.6.1.4.1.15.2.3.7.1.64 | ColumnanxpPppUserRemote | read-write | mandatory | The username used by the Annex to identify itself if the remote PPP peer asks for authentication. This MIB object corresponds to the NA/admin asynchronous port… |
| 1.3.6.1.4.1.15.2.3.7.1.65 | ColumnanxpPppPasswdRemote | read-write | mandatory | The password used by the Annex to identify itself if the remote PPP peer asks for authentication. Reading this parameter will return either <set> if the passwo… |
| 1.3.6.1.4.1.15.2.3.7.1.66 | ColumnanxpLatAuthGroupVal | read-write | mandatory | This port parameter specifies which remote group codes are accessible to a user on a particular Annex port. Each port has its own set of group codes. The synta… |
| 1.3.6.1.4.1.15.2.3.7.1.67 | ColumnanxpPppDialupAddr | read-write | mandatory | local(1) - Disabled. authserver(2) - The Annex requests the PPP dialup addresses from the host-based ACP. dhcp(3) - The Annex requests the PPP dialup addresses… |
| 1.3.6.1.4.1.15.2.3.7.1.68 | ColumnanxpBanner | read-write | mandatory | Specifies whether the Annex banner and message- of-the-day are displayed on the port. The default is enabled. This has four possible actions: default, Y, yes, … |
| 1.3.6.1.4.1.15.2.3.7.1.69 | ColumnanxpPsHistory | read-write | mandatory | Specifies how much data to buffer on a slave port. This MIB object corresponds to the NA/admin asynchronous port parameter 'ps_history_buffer'. |
| 1.3.6.1.4.1.15.2.3.7.1.70 | ColumnanxpLocation | read-write | mandatory | A descriptive string for a this port. This string is displayed by the CLI who command. This MIB object corresponds to the NA/admin asynchronous port parameter … |
| 1.3.6.1.4.1.15.2.3.7.1.71 | ColumnanxpType | read-write | mandatory | The type of device attached to the port. The default is hardwired. This MIB object corresponds to the NA/admin asynchronous port parameter 'type'. |
| 1.3.6.1.4.1.15.2.3.7.1.72 | ColumnanxpCliImask7 | read-write | mandatory | Defines whether input at the CLI is masked to 7 bits. The default is disabled. This MIB object corresponds to the NA/admin asynchronous port parameter 'cli_ima… |
| 1.3.6.1.4.1.15.2.3.7.1.73 | ColumnanxpModemVar | read-write | mandatory | A string defining the type of modem attached to the serial port. This MIB object corresponds to the NA/admin asynchronous port parameter 'type_of_modem'. |
| 1.3.6.1.4.1.15.2.3.7.1.74 | ColumnanxpPppNcp | read-write | mandatory | The protocol running on the interface. This MIB object corresponds to the NA/admin asynchronous port parameter 'ppp_ncp'. Note that all and ipcp-atcp-ipxcp-ccp… |
| 1.3.6.1.4.1.15.2.3.7.1.75 | ColumnanxpDemandDial | read-write | deprecated | When enabled, allows the Annex to instruct the modem attached on the port to dial the phone number defined in anxpNetPhoneNumber. This MIB object corresponds t… |
| 1.3.6.1.4.1.15.2.3.7.1.76 | ColumnanxpPhoneNumber | read-write | mandatory | The phone number used for this port when doing demand dialing. This MIB object corresponds to the NA/admin asynchronous port parameter 'phone_number'. |
| 1.3.6.1.4.1.15.2.3.7.1.77 | ColumnanxpNetInactivity | read-write | mandatory | The number of units allowed for serial protocol inactivity on the port. The type of unit, minutes or seconds, is defined by the object anxpNetInactivityUnits. … |
| 1.3.6.1.4.1.15.2.3.7.1.78 | ColumnanxpAtGuest | read-write | mandatory | If enabled, allows ARAP guest login service. This MIB object corresponds to the NA/admin asynchronous port parameter 'at_guest'. |
| 1.3.6.1.4.1.15.2.3.7.1.79 | ColumnanxpAtNodeid | read-write | mandatory | The default AppleTalk node ID hint that is used by the Annex on this port. The address consists of two parts separated by a dot. The address may be in either h… |
| 1.3.6.1.4.1.15.2.3.7.1.80 | ColumnanxpAtSecurity | read-write | mandatory | Controls whether ACP service is enabled for this port when establishing an AppleTalk connection. This MIB object corresponds to the NA/admin asynchronous port … |
| 1.3.6.1.4.1.15.2.3.7.1.81 | ColumnanxpArapV42bis | read-write | mandatory | Controls whether V.42bis compression is done during an ARAP session. This MIB object corresponds to the NA/admin asynchronous port parameter 'arap_v42bis'. |
| 1.3.6.1.4.1.15.2.3.7.1.82 | ColumnanxpTn3270PrinterHost | read-write | mandatory | The IP address of the machine running a Berkeley-style lpd server. This MIB object corresponds to the NA/admin asynchronous port parameter 'tn3270_printer_name… |
| 1.3.6.1.4.1.15.2.3.7.1.83 | ColumnanxpTn3270PrinterName | read-write | mandatory | A valid printer name contained in the /etc/printcap file on the remote host. This MIB object corresponds to the NA/admin asynchronous port parameter 'tn3270_pr… |
| 1.3.6.1.4.1.15.2.3.7.1.84 | ColumnanxpTcpKeepAlive | read-write | mandatory | The default keep-alive value for connections to this serial port. If this is zero, use the value specified by anxTcpKeepAlive. This MIB object corresponds to t… |
| 1.3.6.1.4.1.15.2.3.7.1.86 | ColumnanxpDtrSignal | read-write | mandatory | Controls the DTR (Data Terminal Ready) output control signal for this serial port. Valid set values are high or low. Setting the value on an idle port will pro… |
| 1.3.6.1.4.1.15.2.3.7.1.87 | ColumnanxpRtsSignal | read-write | mandatory | Controls the RTS (Request to Send) output control signal for this serial port. Valid set values are high or low. Setting the value on an idle port will produce… |
| 1.3.6.1.4.1.15.2.3.7.1.88 | ColumnanxpCliInterface | read-write | mandatory | Specifies either a Unix or VMS command line interface. The default is uci. This MIB object corresponds to the NA/admin asynchronous port parameter 'cli_interfa… |
| 1.3.6.1.4.1.15.2.3.7.1.89 | ColumnanxpAutobaud | read-write | mandatory | When enabled, specifies that the line speed should be determined when opening the connection. The default is disabled. This MIB object corresponds to the NA/ad… |
| 1.3.6.1.4.1.15.2.3.7.1.90 | ColumnanxpDefSessMode | read-write | mandatory | The default session mode when the DECServer command interface is configured. The default is interactive. This MIB object corresponds to the NA/admin asynchrono… |
| 1.3.6.1.4.1.15.2.3.7.1.91 | ColumnanxpIpxSecurity | read-write | mandatory | Controls whether IPX security is enabled on this port. The default is disabled. This MIB object corresponds to the NA/admin asynchronous port parameter 'ipx_se… |
| 1.3.6.1.4.1.15.2.3.7.1.92 | ColumnanxpIpsoClass | read-write | mandatory | Defines the IP security classification for packets sent and received on this port. The default value is none. This MIB object corresponds to the NA/admin async… |
| 1.3.6.1.4.1.15.2.3.7.1.93 | ColumnanxpVciLoginPortPasswd | read-write | mandatory | Enables the port password if the port is configured as a DECServer interface port. The default is disabled. This MIB object corresponds to the NA/admin asynchr… |
| 1.3.6.1.4.1.15.2.3.7.1.94 | ColumnanxpVciLoginTimeout | read-write | mandatory | Enables a login timer if the port is configured as a DECServer interface port. The default is disabled. This MIB object corresponds to the NA/admin asynchronou… |
| 1.3.6.1.4.1.15.2.3.7.1.95 | ColumnanxpDedicatedArgs | read-write | mandatory | Command line arguments to be passed to process started by a dedicated port with mode set to 'telnet', 'tn3270', 'rlogin', 'connect' (if LAT is in use) or 'call… |
| 1.3.6.1.4.1.15.2.3.7.1.96 | ColumnanxpNetInactivityUnits | read-write | mandatory | The type of units that are used for the port's net inactivity timer. See also the anxpNetInactivity object. The default value is 'minutes'. This MIB object cor… |
| 1.3.6.1.4.1.15.2.3.7.1.97 | ColumnanxpResolveProtocol | read-write | mandatory | Default host protocol to use when starting a dedicated port and the protocol is not explicitly specified in the command. Is set to one of 'telnet', connect, or… |
| 1.3.6.1.4.1.15.2.3.7.1.98 | ColumnanxpForwardKey | read-write | mandatory | Defines a control character sequence as an attention character to switch the user to the next session. The Annex-II only allows a single control character (eg.… |
| 1.3.6.1.4.1.15.2.3.7.1.99 | ColumnanxpBackwardKey | read-write | mandatory | Defines a control character sequence as an attention character to switch the user to the previous session. The Annex-II only allows a single control character … |
| 1.3.6.1.4.1.15.2.3.7.1.100 | ColumnanxpPppIpxNetwork | read-write | mandatory | The IPX network number for an IPX PPP connection using this port. When the IPX PPP connection is established the network number will be negotiated. If one end … |
| 1.3.6.1.4.1.15.2.3.7.1.101 | ColumnanxpPppIpxNode | read-write | mandatory | The IPX node number for an IPX PPP connection using this port. The value of this object is a 12 digit hexadecimal number string representing the IPX node numbe… |
| 1.3.6.1.4.1.15.2.3.7.1.102 | ColumnanxpLatAuthMap | read-write | mandatory | This port parameter is functionally identical to anxpLatAuthGroupVal and corresponds to the NA/admin Annex parameter 'group_value'. The syntax of this object i… |
| 1.3.6.1.4.1.15.2.3.7.1.103 | ColumnanxpMultiSession | read-write | mandatory | This parameter allows multisession operation to be managed on a per port basis. This MIB object corresponds to the NA/admin port parameter 'multisessions'. To … |
| 1.3.6.1.4.1.15.2.3.7.1.104 | ColumnanxpAutoTimeout | read-write | mandatory | This parameter allows a user to specify the maximum amount of time the annex should wait before dropping into cli mode. This parameter will specify the amount … |
| 1.3.6.1.4.1.15.2.3.7.1.105 | ColumnanxpAutoPPPSecurity | read-write | mandatory | This parameter should be used together with the ppp_security_protocol parameter. If this object is set to enable and if the user comes in as CLI and then goes … |
| 1.3.6.1.4.1.15.2.3.8 | TableportStatsTable | not-accessible | mandatory | Table of current port status entries. |
| 1.3.6.1.4.1.15.2.3.8.1 | RowportStatsEntry | not-accessible | mandatory | The port's current status parameters. If the port is not in use, no values are returned for that port. |
| 1.3.6.1.4.1.15.2.3.8.1.1 | ColumnanxpPortStatsIndex | read-only | mandatory | A unique number from 1 to the sum of the number of asynchronous ports, synchronous ports, and virtual ports. The numbers from 1 to totalPorts represent the asy… |
| 1.3.6.1.4.1.15.2.3.8.1.2 | ColumnanxpCurrentUserName | read-only | mandatory | The name of the current user on this port. The string '<unknown>' is returned if the port is in use but the current user name cannot be determined. |
| 1.3.6.1.4.1.15.2.3.8.1.3 | ColumnanxpPortIdleTime | read-only | mandatory | The length of time in DD:HH:MM since the last activity on this port. |
| 1.3.6.1.4.1.15.2.3.8.1.4 | ColumnanxpPortLoginTime | read-only | mandatory | Displays the time that the port was opened from the Annex time-of-the-day clock. |
| 1.3.6.1.4.1.15.2.3.8.1.5 | ColumnanxpPortProto | read-only | mandatory | This object returns the information that is similar to when the command 'who' is typed on the CLI. CLI - The port is a CLI port and was opened by a device conn… |
| 1.3.6.1.4.1.15.2.3.8.1.6 | ColumnanxpPortJobs | read-only | mandatory | Port Job list for this cli port. |
| 1.3.6.1.4.1.15.2.4.1 | ScalaranxpParaPorts | read-only | mandatory | The number of parallel ports on this Annex. |
| 1.3.6.1.4.1.15.2.4.2 | TableanxpParaPortTable | not-accessible | mandatory | Table of parallel port parameters. |
| 1.3.6.1.4.1.15.2.4.2.1 | RowanxpParaPortEntry | not-accessible | mandatory | The Annex parallel port configuration parameters. |
| 1.3.6.1.4.1.15.2.4.2.1.1 | ColumnanxpParaPortIndex | read-only | mandatory | A unique number from 1 to anxpParaPorts that identifies each parallel port. |
| 1.3.6.1.4.1.15.2.4.2.1.2 | ColumnanxpParaPortHardwareTabs | read-write | mandatory | This parameter controls whether the Annex will send a tab character to the printer. If disabled, the tab is replaced with spaces. This MIB object corresponds t… |
| 1.3.6.1.4.1.15.2.4.2.1.3 | ColumnanxpParaPortMapToUpper | read-write | mandatory | When enabled, the Annex translates all lower case characters to upper case before transmitting the characters to the printer port. This MIB object corresponds … |
| 1.3.6.1.4.1.15.2.4.2.1.4 | ColumnanxpParaPortPrinterWidth | read-write | mandatory | The defined maximum number of characters per printer line. The Annex will insert a <newline> character after the specified number of characters are output on t… |
| 1.3.6.1.4.1.15.2.4.2.1.5 | ColumnanxpParaPortInterface | read-write | mandatory | The type of printer attached to the port. This MIB object corresponds to the NA/admin parallel port parameter 'type'. |
| 1.3.6.1.4.1.15.2.4.2.1.6 | ColumnanxpParaPortSpeed | read-write | mandatory | The printer speed on the Micro-Annex. If this is an Annex-3 and the printer type is Centronics, the default is 'normal'. It should not be necessary to change t… |
| 1.3.6.1.4.1.15.2.4.2.1.7 | ColumnanxpParaPortCRLF | read-write | mandatory | When enabled, the Annex converts a carriage-return character to carriage-return/line-feed. This MIB object corresponds to the NA/admin parallel port parameter … |
| 1.3.6.1.4.1.15.2.4.2.1.8 | ColumnanxpParaPortTcpKeepAlive | read-write | mandatory | The default keep-alive value for connections to this parallel port. If this is zero, use the value specified by anxTcpKeepAlive. This MIB object corresponds to… |
| 1.3.6.1.4.1.15.2.9.1 | ScalartotalSyncPorts | read-only | mandatory | The number of synchronous ports on this Annex. |
| 1.3.6.1.4.1.15.2.9.2 | ScalartotalSyncInChars | read-only | mandatory | The total number of characters received on all synchronous ports. |
| 1.3.6.1.4.1.15.2.9.3 | ScalartotalSyncOutChars | read-only | mandatory | The total number of characters transmitted on all synchronous ports. |
| 1.3.6.1.4.1.15.2.9.4 | ScalartotalSyncFrameCheckErrs | read-only | mandatory | The total number of frame check errors detected on all synchronous ports since the last boot. |
| 1.3.6.1.4.1.15.2.9.5 | ScalartotalSyncXmitUnderrunErrs | read-only | mandatory | The total number of transmit underrun errors detected on all synchronous ports since the last boot. |
| 1.3.6.1.4.1.15.2.9.6 | ScalartotalSyncRecvOverrunErrs | read-only | mandatory | The total number of receive overrun errors detected on all synchronous ports since the last boot. |
| 1.3.6.1.4.1.15.2.9.7 | TableanxSyncTable | not-accessible | mandatory | Table of synchronous port parameters. |
| 1.3.6.1.4.1.15.2.9.7.1 | RowanxSyncEntry | not-accessible | mandatory | The synchronous port's parameters. |
| 1.3.6.1.4.1.15.2.9.7.1.1 | ColumnanxSyncPortIndex | read-only | mandatory | A unique number from 1 to totalSyncPorts that identifies each synchronous port. |
| 1.3.6.1.4.1.15.2.9.7.1.2 | ColumnanxSyncMode | read-write | mandatory | This parameter defines the mode for access to the synchronous port. The default is unused. This MIB object corresponds to the NA/admin synchronous port paramet… |
| 1.3.6.1.4.1.15.2.9.7.1.3 | ColumnanxSyncClocking | read-write | mandatory | The clock rate (in Kbps) supplied for this port. The allowable values are '56', '64', '112', '128' or 'external'. The default value is 'external'. This MIB obj… |
| 1.3.6.1.4.1.15.2.9.7.1.4 | ColumnanxSyncLocalUser | read-write | mandatory | A string specifying the default user name for the port. The default value is a zero length string. This MIB object corresponds to the NA/admin synchronous port… |
| 1.3.6.1.4.1.15.2.9.7.1.5 | ColumnanxSyncPortPassword | read-write | mandatory | The port password. The default value is '<unset>'. This MIB object corresponds to the NA/admin synchronous port parameter 'port_password'. |
| 1.3.6.1.4.1.15.2.9.7.1.6 | ColumnanxSyncLocalAddr | read-write | mandatory | The Internet address for the Annex's side of the point-to-point link. This MIB object corresponds to the NA/admin synchronous port parameter 'local_address'. |
| 1.3.6.1.4.1.15.2.9.7.1.7 | ColumnanxSyncRemoteAddr | read-write | mandatory | The Internet address for the host at the remote end of the point-to-point link. This MIB object corresponds to the NA/admin synchronous port parameter 'remote_… |
| 1.3.6.1.4.1.15.2.9.7.1.8 | ColumnanxSyncMetric | read-write | mandatory | This parameter defines the hop count to the remote end of the synchronous interface. This MIB object corresponds to the NA/admin synchronous port parameter 'me… |
| 1.3.6.1.4.1.15.2.9.7.1.9 | ColumnanxSyncAllowCompression | read-write | mandatory | When enabled, the Annex will use TCP/IP header compression on this link only if the other end of the link initiates the compression. This MIB object correspond… |
| 1.3.6.1.4.1.15.2.9.7.1.10 | ColumnanxSyncPppMru | read-write | mandatory | This parameter defines the maximum receive unit in bytes. The default value is 1500. This MIB object corresponds to the NA/admin synchronous port parameter 'pp… |
| 1.3.6.1.4.1.15.2.9.7.1.11 | ColumnanxSyncPppSecurityProto | read-write | mandatory | Defines which security protocol will be used to authenticate the remote user. This parameter must be set and the Annex enable_security (anxEnableSecurity) must… |
| 1.3.6.1.4.1.15.2.9.7.1.12 | ColumnanxSyncPppUserRemote | read-write | mandatory | The username used by the Annex to identify itself if the remote PPP peer asks for authentication. Reading this parameter will return either <set> if the userna… |
| 1.3.6.1.4.1.15.2.9.7.1.13 | ColumnanxSyncPppPasswdRemote | read-write | mandatory | The username used by the Annex to identify itself if the remote PPP peer asks for authentication. Reading this parameter will return either <set> if the passwo… |
| 1.3.6.1.4.1.15.2.9.7.1.14 | ColumnanxSyncPppNcp | read-write | mandatory | The protocol running on the interface. This MIB object corresponds to the NA/admin synchronous port parameter 'ppp_ncp'. |
| 1.3.6.1.4.1.15.2.9.7.1.15 | ColumnanxSyncLocation | read-write | mandatory | A string specifying location information for the port. The default value is a zero length string. This MIB object corresponds to the NA/admin synchronous port … |
| 1.3.6.1.4.1.15.2.9.7.1.16 | ColumnanxSyncForceCTS | read-write | mandatory | Allows the control of CTS for the synchronous port. If disabled, CTS will assume the level of the interface. If the attached device does not assert CTS, this p… |
| 1.3.6.1.4.1.15.2.9.7.1.17 | ColumnanxSyncSubNetMask | read-write | mandatory | The subnet mask address for the local end of the point-to-point link. This MIB object corresponds to the NA/admin synchronous port parameter 'subnet_mask'. |
| 1.3.6.1.4.1.15.2.9.7.1.18 | ColumnanxSyncDialupAddr | read-write | mandatory | When enabled, the Annex requests the PPP dialup addresses from the host-based ACP for this synchronous port. This MIB object corresponds to the NA/admin synchr… |
| 1.3.6.1.4.1.15.2.9.7.1.19 | ColumnanxSyncPppSecurity | read-write | mandatory | The master security switch for this synchronous port. When enabled, the value of the anxSyncPppSecurityProto object determines the security protocol to use. Th… |
| 1.3.6.1.4.1.15.2.100.1 | TableanxmStatsTable | not-accessible | deprecated | Table of phone call statistics and accounting parameters. This information is cleared each time the Annex is rebooted. The maximum number of entries is defined… |
| 1.3.6.1.4.1.15.2.100.1.1 | RowanxmStatsEntry | not-accessible | deprecated | The modem statistics and accounting parameter objects. |
| 1.3.6.1.4.1.15.2.100.1.1.1 | ColumnanxmStatsIndex | read-only | deprecated | A unique number generated to identify the particular call. |
| 1.3.6.1.4.1.15.2.100.1.1.2 | ColumnanxmStatsPort | read-only | deprecated | The port number on which phone call took place. |
| 1.3.6.1.4.1.15.2.100.1.1.3 | ColumnanxmStatsModemType | read-only | deprecated | The type of modem which was on the port at the time of the call. |
| 1.3.6.1.4.1.15.2.100.1.1.4 | ColumnanxmStatsTime | read-only | deprecated | The time when the phone call was initiated. |
| 1.3.6.1.4.1.15.2.100.1.1.5 | ColumnanxmStatsNumber | read-only | deprecated | The number to which this call was made. If the call was not initiated by the Annex, this is value is returned as a zero length string. |
| 1.3.6.1.4.1.15.2.100.1.1.6 | ColumnanxmStatsDuration | read-only | deprecated | Duration of the phone call. |
| 1.3.6.1.4.1.15.2.100.1.1.7 | ColumnanxmStatsUsername | read-only | deprecated | Name of the user associated with this port at the time of the call. |
| 1.3.6.1.4.1.15.2.100.1.1.8 | ColumnanxmStatsStatus | read-only | deprecated | Describes the status of the call; active, normal termination, or aborted. |
| 1.3.6.1.4.1.15.2.100.2 | TableanxpModemTable | not-accessible | mandatory | A table of modem configuration information for the ports. |
| 1.3.6.1.4.1.15.2.100.2.1 | RowanxpModemEntry | not-accessible | mandatory | A row in the port's modem configuration table. |
| 1.3.6.1.4.1.15.2.100.2.1.1 | ColumnanxpModemIndex | read-only | mandatory | The port number for this modem configuration. |
| 1.3.6.1.4.1.15.2.100.2.1.2 | ColumnanxpModemConfig | read-write | mandatory | The purpose for which this modem is configured. When set, this object will change a set of parameters to configure the modem for the specified purpose. The val… |
| 1.3.6.1.4.1.15.2.100.2.1.3 | ColumnanxpModemReset | read-write | deprecated | A control to force the internal modem into a clean, initial state, through a hardware reset. In response to a get-request or get-next-request, the agent always… |
| 1.3.6.1.4.1.15.2.100.2.1.4 | ColumnanxpModemStatus | read-write | deprecated | This object sets the status of the modem. Explanation of the values are as follows: 1 - Make modem available if busied out. 2 - Busy out a modem. 3 - Boot-up d… |
| 1.3.6.1.4.1.15.2.100.2.1.5 | ColumnanxpModemBChannel | read-only | mandatory | This object returns the B channel number that is using the modem. This object is valid only if the status of the modem is used. This MIB object displays the si… |
| 1.3.6.1.4.1.15.2.100.2.1.6 | ColumnanxpModemWhenBusy | read-only | deprecated | This object returns when the modem was busied out. This object is valid only when the modem status is busied-out(2). This MIB object displays the similar infor… |
| 1.3.6.1.4.1.15.2.100.2.1.7 | ColumnanxpModemTotalCalls | read-only | deprecated | This object maintains the count of number of times the line is seized on a modem. The line is seized when a call arrives on that line. |
| 1.3.6.1.4.1.15.2.100.2.1.8 | ColumnanxpModemRingFail | read-only | mandatory | This object maintains the count of number of times the modem failed to ring on a call. The counter is maintained since the last reboot. |
| 1.3.6.1.4.1.15.2.100.2.1.9 | ColumnanxpModemOffhookFail | read-only | mandatory | This object maintains the count of number of times the modem failed to go offhook on a call. The counter is maintained since the last reboot. |
| 1.3.6.1.4.1.15.2.100.2.1.10 | ColumnanxpModemDcdFail | read-only | mandatory | This object maintains the count of number of times the modem failed to assert DCD on a call. The DCD is asserted when a call is accepted by the modem. The coun… |
| 1.3.6.1.4.1.15.2.100.2.1.11 | ColumnanxpModemConsecFail | read-only | mandatory | This object maintains the count of number of times the modem failed to accept a call consecutively. The counter gets initialized on every successfull call or w… |
| 1.3.6.1.4.1.15.2.100.2.1.12 | ColumnanxpModemFirmware | read-only | deprecated | Modem firmware version string. Note: If the object returns a Nosuchname then it is possible that modem is being upgraded by AFD or some other tool. |