MIB Viewer

ZTE-AN-PETH-MIB

48 objects
This MIB defines Description of zte power ethernet managed objects.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3902.1015.300IdentityzxAnPethMibThis MIB defines Description of zte power ethernet managed objects.
1.3.6.1.4.1.3902.1015.300.1NodezxAnPethObjects
1.3.6.1.4.1.3902.1015.300.1.1NodezxAnPethGlobalObjects
1.3.6.1.4.1.3902.1015.300.1.1.1ScalarzxAnPethPsePmModeread-writecurrentThe power management mode. Possible values are: none (1) - Power management is not performed by default, The user must power-up the port manually. staticPowerW…
1.3.6.1.4.1.3902.1015.300.1.1.2ScalarzxAnPethPseActualCurrentread-onlycurrentThe actual momentary current.
1.3.6.1.4.1.3902.1015.300.1.1.3ScalarzxAnPethPseActualVoltageread-onlycurrentThe actual momentary input line voltage.
1.3.6.1.4.1.3902.1015.300.1.1.4ScalarzxAnPethPseChipTempread-onlycurrentThe temperature of the PSE chip.
1.3.6.1.4.1.3902.1015.300.1.1.5ScalarzxAnPethPseChipTempAlmThreshread-writecurrentThe temperature alarm threshold of the PSE chip.
1.3.6.1.4.1.3902.1015.300.1.1.6ScalarzxAnPethPseChipTempTrapEnableread-writecurrentEnable/disable the zxAnPethPseChipHighTempAlm and zxAnPethPseChipHighTempClr.
1.3.6.1.4.1.3902.1015.300.1.1.7ScalarzxAnPethPseOutVoltageUpperThreshread-writecurrentThe upper threshold of PSE output volts. The alarm should be generated when zxAnPethPseActualVoltage exceeds this threshold. zxAnPethPseOutVoltageUpperThresh m…
1.3.6.1.4.1.3902.1015.300.1.1.8ScalarzxAnPethPseOutVoltageLowerThreshread-writecurrentThe lower threshold of PSE output volts. The alarm should be generated when zxAnPethPseActualVoltage is lower than this threshold. zxAnPethPseOutVoltageLowerTh…
1.3.6.1.4.1.3902.1015.300.1.1.9ScalarzxAnPethPseFirmwareVersionread-onlycurrentThe PSE firmware version.
1.3.6.1.4.1.3902.1015.300.1.1.10ScalarzxAnPethMainPsePowerLimitread-writecurrentThe power threshhold of PSE output.
1.3.6.1.4.1.3902.1015.300.1.1.11ScalarzxAnPethMainPsePowerUsageThreshread-writecurrentThe PSE power usage threshold. When pethMainPseConsumptionPower is larger than zxAnPethMainPsePowerUsageThresh, pethMainPowerUsageOnNotification will be sent. …
1.3.6.1.4.1.3902.1015.300.1.2TablezxAnPethPsePortTablenot-accessiblecurrentPeth Port Table
1.3.6.1.4.1.3902.1015.300.1.2.1RowzxAnPethPsePortEntrynot-accessiblecurrentPeth Port Entry
1.3.6.1.4.1.3902.1015.300.1.2.1.1ColumnzxAnPethPsePortForcePowerEnableread-writecurrentEnable/disable force power on this interface. and force power on the specified port without detection.
1.3.6.1.4.1.3902.1015.300.1.2.1.2ColumnzxAnPethPsePortActualVoltageread-onlycurrentThe actual voltage of this port.
1.3.6.1.4.1.3902.1015.300.1.2.1.3ColumnzxAnPethPsePortActualCurrentread-onlycurrentThe actual current of this port.
1.3.6.1.4.1.3902.1015.300.1.2.1.4ColumnzxAnPethPsePortActualPowerread-onlycurrentThe actual power of this port.
1.3.6.1.4.1.3902.1015.300.1.2.1.5ColumnzxAnPethPsePortMaxPowerread-writecurrentThe maximum power of this port.
1.3.6.1.4.1.3902.1015.300.1.2.1.6ColumnzxAnPethPsePortDetectionTyperead-writecurrentDescribes the detection type of the port PD detection. NoDetection indicates force power on the port without detection, LegacyOnly indicates legacy detection o…
1.3.6.1.4.1.3902.1015.300.1.2.1.7ColumnzxAnPethPsePortWorkModeread-onlycurrentPSE port working mode.
1.3.6.1.4.1.3902.1015.300.1.2.1.8ColumnzxAnPethPsePortResetread-writecurrentReset port.
1.3.6.1.4.1.3902.1015.300.1.2.1.9ColumnzxAnPethPsePortOperStatusread-onlycurrentPSE port operational status.
1.3.6.1.4.1.3902.1015.300.1.2.1.10ColumnzxAnPethPsePortDetailInforead-onlycurrentPSE port detail information. When zxAnPethPsePortOperStatus is 'down', this object will be show the detail information of port.
1.3.6.1.4.1.3902.1015.300.1.2.1.11ColumnzxAnPethPsePortTrapEnableread-writecurrentEnable/disable the zxAnPethPsePortStatusUp and zxAnPethPsePortStatusDown.
1.3.6.1.4.1.3902.1015.300.1.3TablezxAnPethPseCardTablenot-accessiblecurrentPeth Card Table
1.3.6.1.4.1.3902.1015.300.1.3.1RowzxAnPethPseCardEntrynot-accessiblecurrentPeth Card Entry
1.3.6.1.4.1.3902.1015.300.1.3.1.1ColumnzxAnPethPseRacknot-accessiblecurrentRack No.
1.3.6.1.4.1.3902.1015.300.1.3.1.2ColumnzxAnPethPseShelfnot-accessiblecurrentShelf No.
1.3.6.1.4.1.3902.1015.300.1.3.1.3ColumnzxAnPethPseSlotnot-accessiblecurrentCard No.
1.3.6.1.4.1.3902.1015.300.1.3.1.4ColumnzxAnPethPseCardSupportPoeread-onlycurrentThis variable indicates whether the card supports PoE management.
1.3.6.1.4.1.3902.1015.300.1.4TablezxAnPethPdePortTablenot-accessiblecurrentPDE(Power Device Equipment) port information.
1.3.6.1.4.1.3902.1015.300.1.4.1RowzxAnPethPdePortEntrynot-accessiblecurrentPDE port entry.
1.3.6.1.4.1.3902.1015.300.1.4.1.1ColumnzxAnPethPdePortAutoCheckEnableread-writecurrentEnable/disable to check port power status automatically.
1.3.6.1.4.1.3902.1015.300.1.4.1.2ColumnzxAnPethPdePortPowerSupplyStatusread-onlycurrentThe port power status.
1.3.6.1.4.1.3902.1015.300.2NodezxAnPethTrapObjects
1.3.6.1.4.1.3902.1015.300.2.1NotificationzxAnPethPseChipHighTempAlmcurrentThe PSE chip temperature has exceeded normal operating temperature zxAnPethPseChipTempAlmThresh. The zxAnPethPseChipTemp object identifies the current status.
1.3.6.1.4.1.3902.1015.300.2.2NotificationzxAnPethPseChipHighTempClrcurrentThe PSE chip temperature has returned to normal operating temperature zxAnPethPseChipTempAlmThresh. The zxAnPethPseChipTemp object identifies the current statu…
1.3.6.1.4.1.3902.1015.300.2.3NotificationzxAnPethPsePortStatusUpcurrentA zxAnPethPsePortStatusUp is sent when zxAnPethPsePortOperStatus changes to up.
1.3.6.1.4.1.3902.1015.300.2.4NotificationzxAnPethPsePortStatusDowncurrentA zxAnPethPsePortStatusDown is sent when zxAnPethPsePortOperStatus changes to down.
1.3.6.1.4.1.3902.1015.300.2.5NotificationzxAnPethPseOverVoltageAlmcurrentIt indicates that the PSE voltage is over-voltage.
1.3.6.1.4.1.3902.1015.300.2.6NotificationzxAnPethPseOverVoltageClrcurrentIt indicates that the over-voltage fault is cleared.
1.3.6.1.4.1.3902.1015.300.2.7NotificationzxAnPethPseUnderVoltageAlmcurrentIt indicates that the PSE voltage is under-voltage.
1.3.6.1.4.1.3902.1015.300.2.8NotificationzxAnPethPseUnderVoltageClrcurrentIt indicates that the under-voltage fault is cleared.
1.3.6.1.4.1.3902.1015.300.2.9NotificationzxAnPethPdePortPowerOffAlmcurrentA zxAnPethPdePortPowerOffAlm is sent when zxAnPethPdePortPowerStatus is off(2).
1.3.6.1.4.1.3902.1015.300.2.10NotificationzxAnPethPdePortPowerOffClrcurrentA zxAnPethPdePortPowerOffClr is sent when zxAnPethPdePortPowerOffAlm is cleared.