MIB Viewer

ZTE-AN-PORT-LOCATING-MIB

36 objects
This MIB defines PortLocating managed objects for Access Node.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.3902.1015.32IdentityzxAnPortLocatingMibThis MIB defines PortLocating managed objects for Access Node.
1.3.6.1.4.1.3902.1015.32.1ScalarzxAnPortIdAccessNodeNameread-writecurrentAccess node name.
1.3.6.1.4.1.3902.1015.32.2ScalarzxAnPortIdAccessNodeIdTyperead-writecurrentAccess Node Identifier type. 1: inband-mac, 2: hostname
1.3.6.1.4.1.3902.1015.32.3ScalarzxAnPortIdRackread-writecurrentRack of this NE used in port locating application.
1.3.6.1.4.1.3902.1015.32.4ScalarzxAnPortIdShelfread-writecurrentFrame of this NE used in port locating application.
1.3.6.1.4.1.3902.1015.32.5ScalarzxAnPortLocatingCircuitIdSyntaxEnableread-writecurrentPort locating Circuit ID Syntax enable switch.
1.3.6.1.4.1.3902.1015.32.6ScalarzxAnPortLocatingAccessLoopEncapsulationEnableread-writecurrentPort access loop encapsulation enable.
1.3.6.1.4.1.3902.1015.32.7ScalarzxAnPortIdAccessNodeSlaveIdread-writecurrentThis field is designed for Deutsche Telekom. By using the DHCP relay agent function the device must be able to create the CID and the RID as described in BBF T…
1.3.6.1.4.1.3902.1015.32.8ScalarzxAnPortIdDhcpV4AccessLoopCharread-writecurrentAccess loop characteristics of DHCP packet. The bit value 1 means the suboption represented by this bit is supported. It used only by DHCP.
1.3.6.1.4.1.3902.1015.32.9ScalarzxAnPortIdPppoeAccessLoopCharread-writecurrentAccess loop characteristics of PPPoE packet. The bit value 1 means the suboption represented by this bit is supported. It used by PPPoE.
1.3.6.1.4.1.3902.1015.32.20TablezxAnPortLocatingTablenot-accessiblecurrentport Locating table
1.3.6.1.4.1.3902.1015.32.20.1RowzxAnPortLocatingEntrynot-accessiblecurrentport Locating entry.
1.3.6.1.4.1.3902.1015.32.20.1.1ColumnzxAnPortLocatingIndexnot-accessiblecurrentThe ifindex of the port location.
1.3.6.1.4.1.3902.1015.32.20.1.2ColumnzxAnPortIdIfConfFormatread-writecurrentFormat of port locating.
1.3.6.1.4.1.3902.1015.32.20.1.3ColumnzxAnPortIdIfConfRidEnableread-writecurrentenable = 1, disable = 2
1.3.6.1.4.1.3902.1015.32.20.1.4ColumnzxAnPortIdIfConfRidread-writecurrent
1.3.6.1.4.1.3902.1015.32.20.1.5ColumnzxAnPortLocatingIfaceAccessLoopCharEnableread-writecurrentAccess Loop Characteristics enable switch.
1.3.6.1.4.1.3902.1015.32.20.1.6ColumnzxAnPortIdIfConfUserDefinedCidread-writecurrent
1.3.6.1.4.1.3902.1015.32.20.1.7ColumnzxAnPortIdIfConfFormatProfileread-writecurrentFormat profile of port identification.
1.3.6.1.4.1.3902.1015.32.20.1.8ColumnzxAnPortIdIfConfRidFormatProfileread-writecurrentFormat profile of remote ID.
1.3.6.1.4.1.3902.1015.32.22TablezxAnPortLocatingCircuitIdSyntaxTablenot-accessiblecurrentPort locating Circuit ID Syntax table.
1.3.6.1.4.1.3902.1015.32.22.1RowzxAnPortLocatingCircuitIdSyntaxEntrynot-accessiblecurrentPort locating Circuit ID Syntax entry.
1.3.6.1.4.1.3902.1015.32.22.1.1ColumnzxAnPortLocatingCircuitIdSyntaxIndexnot-accessiblecurrentA first key that identifies the Circuit ID Syntax.
1.3.6.1.4.1.3902.1015.32.22.1.2ColumnzxAnPortLocatingCircuitIdComponentIndexnot-accessiblecurrentA second key that identifies a component in the Circuit ID Syntax.
1.3.6.1.4.1.3902.1015.32.22.1.3ColumnzxAnPortLocatingCircuitIdComponentTyperead-createcurrentAn attribute that identifies the type of this component. The following types are possible: standardVar - A TR-101 based variable(1: access node id, 2: chassis,…
1.3.6.1.4.1.3902.1015.32.22.1.4ColumnzxAnPortLocatingCircuitIdComponentIdread-createcurrentA unique and content sensitive identifier for the specific definition of this component. The following identifiers are expected: A row number in table 2 of TR-…
1.3.6.1.4.1.3902.1015.32.22.1.5ColumnzxAnPortLocatingCircuitIdComponentWidthread-createcurrentThe width of the port locating Circuit ID Syntax component.If the length of component is less than the width then fill zero in front of the component.The width…
1.3.6.1.4.1.3902.1015.32.22.1.6ColumnzxAnPortLocatingCidComponentStrread-createcurrentInformation configured by the network operator.The recommandation of default value is ''.When the value of zxAnPortLocatingCircuitIdComponentType is userDefine…
1.3.6.1.4.1.3902.1015.32.22.1.20ColumnzxAnPortLocatingCircuitIdComponentRowStatusread-createcurrentThe row status of this entry.
1.3.6.1.4.1.3902.1015.32.25NodezxAnVlanPortLocatingObjects
1.3.6.1.4.1.3902.1015.32.25.1ScalarzxAnVlanPortLocatingEnableread-writecurrentEnable or disable VLAN port locating.1-truth,2-false.
1.3.6.1.4.1.3902.1015.32.25.2TablezxAnVlanPortLocatingTablenot-accessiblecurrentVLAN Port locating table.When zxAnVlanPortLocatingEnable equal 'truth',this table is effective.
1.3.6.1.4.1.3902.1015.32.25.2.1RowzxAnVlanPortLocatingEntrynot-accessiblecurrent
1.3.6.1.4.1.3902.1015.32.25.2.1.1ColumnzxAnPortLocatingVlannot-accessiblecurrentA key that identifies the vlan port location.
1.3.6.1.4.1.3902.1015.32.25.2.1.20ColumnzxAnPortLocatingVlanRowStatusread-createcurrentThe row status of this entry.
Type Definitions
NameSyntaxStatusDescription
ZxAnAccessLoopTagTypeBITS { suboption81(0), suboption82(1), suboption83(2), suboption84(3), suboption85(4), suboption86(5), suboption87(6), suboption88(7), suboption89(8), suboption8A(9), suboption8B(10), suboption8C(11), suboption8D(12), suboption8E(13) }currentA set of access loop characteristics defined in TR-101 about DSL line, each bit refers to a suboption: Bit 00 : Suboption81, actual data rate upstream. Bit 01 : Suboption82, actual data rate downstream. Bit 02 : Subopti…