MIB Viewer

ZTE-DSL-CPE-MGMT-MIB

28 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3902.1004.17IdentityzxDslCPEMib
1.3.6.1.4.1.3902.1004.17.1TablezxDslPortCPETablenot-accessiblecurrentA table entry containing Port CPE information for each port.
1.3.6.1.4.1.3902.1004.17.1.1RowzxDslPortCPEEntrynot-accessiblecurrentDsl Port CPE information entry
1.3.6.1.4.1.3902.1004.17.1.1.1ColumnzxDslPortCPEIpAddrread-writecurrent
1.3.6.1.4.1.3902.1004.17.1.1.2ColumnzxDslPortMgmtPvcEncapsTyperead-writecurrentRFC 1483 Multiprotocol Encapsulation for CPE management PVC.
1.3.6.1.4.1.3902.1004.17.2TablezxcpeConifgInfoTablenot-accessiblecurrentCPE configuration table
1.3.6.1.4.1.3902.1004.17.2.1RowzxcpeConifgInfoEntrynot-accessiblecurrentCPE configuration entry
1.3.6.1.4.1.3902.1004.17.2.1.1ColumnzxcpeAutoCfgAdminStatusread-writecurrentAuto configuration administatus of CPE
1.3.6.1.4.1.3902.1004.17.2.1.2ColumnzxcpePvcAdminStatusread-writecurrentCPE base PVC administatus
1.3.6.1.4.1.3902.1004.17.2.1.3ColumnzxcpePvcVpiread-writecurrentCPE PVC VPI
1.3.6.1.4.1.3902.1004.17.2.1.4ColumnzxcpePvcVciread-writecurrentCPE PVC VCI
1.3.6.1.4.1.3902.1004.17.2.1.5ColumnzxcpeSysInfoConfigIdread-onlycurrentCPE configuration id
1.3.6.1.4.1.3902.1004.17.2.1000NodeimportZteCpeMib
1.3.6.1.4.1.3902.1004.17.3TablezxcpeTrapInfoTablenot-accessiblecurrentCPE trap infomation table
1.3.6.1.4.1.3902.1004.17.3.1RowzxcpeTrapInfoEntrynot-accessiblecurrentCPE trap infomation entry
1.3.6.1.4.1.3902.1004.17.3.1.1ColumnzxcpeAdministrableStatusread-onlycurrentstatus of CPE
1.3.6.1.4.1.3902.1004.17.3.1.2ColumnzxcpeAutoCfgOperStatusread-onlycurrentCPE auto configuration status
1.3.6.1.4.1.3902.1004.17.3.1.3ColumncpeSysInfoChipSetread-onlycurrentChipset Vendor ID, chipset type and firmware information.
1.3.6.1.4.1.3902.1004.17.3.1.4ColumnzxcpeSysInfoSystemVersionread-onlycurrentCPE system vresion
1.3.6.1.4.1.3902.1004.17.3.1.5ColumnzxcpeSysInfoProductIdread-onlycurrentCPE product id
1.3.6.1.4.1.3902.1004.17.3.1.6ColumnzxcpeSysInfoVendorIdread-onlycurrentCPE vendor id
1.3.6.1.4.1.3902.1004.17.3.1.7ColumnzxcpeSysInfoManufacturerOuiread-onlycurrentCPE Manufacturer Oui
1.3.6.1.4.1.3902.1004.17.3.1.8ColumnzxcpeSysInfoWorkModeread-onlycurrentCPE Work Mode
1.3.6.1.4.1.3902.1004.17.3.1.9ColumnzxcpeSysInfoSerialNumberread-onlycurrentCPE?��s physical number
1.3.6.1.4.1.3902.1004.17.3.1.10ColumnzxcpeSysInfoMibVersionread-onlycurrentCPE Mib Version
1.3.6.1.4.1.3902.1004.17.4ScalarzxcpeSnmpProxyread-writecurrentDSLAM's proxy type for CPE.
1.3.6.1.4.1.3902.1004.17.5ScalarzxcpeCfgFlashClearread-writecurrentClear part of flash for CPE configuration data section.
1.3.6.1.4.1.3902.1004.17.6ScalarzxcpeCfgMgmtVlanread-writecurrentVlan used to support cpe management,such as cpe version download and configuration.It is used by VDSL cpe only now.