MIB Viewer

ZXSONETIF-MIB

26 objects
The MIB module to describe DS1, E1, DS2, and E2 interfaces objects.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3902.1015.1013.2.1.3IdentityzxSonetIfMIBThe MIB module to describe DS1, E1, DS2, and E2 interfaces objects.
1.3.6.1.4.1.3902.1015.1013.2.1.3.1TablezxSonetCfgTablenot-accessiblecurrentThe SONET/SDH Medium table.
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1RowzxSonetCfgEntrynot-accessiblecurrentAn entry in the SONET/SDH Medium table.
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.1ColumnzxSonetIfIndexnot-accessibledeprecatedThe 4 bytes index includes: interface type(bit31~28);shelfId(bit27~24);slotId(bit23~16); portId(bit15~8);reserved(bit7~bit0) .
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.2ColumnzxSonetLoopBackTyperead-writecurrentRepresents the desired loopback configuration of the SONET line. noLoopback: Not in the loopback state. lineLoop: The received signal at this interface does no…
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.3ColumnzxSonetClockSourceread-writecurrentThe source of Transmit Clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock…
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.4ColumnzxSonetConfigTyperead-onlycurrentRepresents the configured line type.This object is used to switch between SONET(North American)and SDH(European) format. Sts is SONET format, while Stm is SDH …
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.5ColumnzxSonetConfigMapTyperead-writecurrent
1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.6ColumnzxSonetCfgInfoSendread-writecurrentThe action to send the configuration of Sonet line to corresponding card.
1.3.6.1.4.1.3902.1015.1013.2.1.3.2TablezxSonetMediumTablenot-accessiblecurrentThe SONET/SDH Medium table.
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1RowzxSonetMediumEntrynot-accessiblecurrentAn entry in the SONET/SDH Medium table.
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.1ColumnzxSonetMediumTyperead-writecurrentThis variable identifies whether a SONET or a SDH signal is used across this interface.
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.2ColumnzxSonetMediumTimeElapsedread-onlycurrentThe number of seconds, including partial seconds, that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adju…
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.3ColumnzxSonetMediumValidIntervalsread-onlycurrentThe number of previous 15-minute intervals for which data was collected. A SONET/SDH interface must be capable of supporting at least n intervals. The minimum …
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.4ColumnzxSonetMediumLineCodingread-writecurrentThis variable describes the line coding for this interface. The B3ZS and CMI are used for electrical SONET/SDH signals (STS-1 and STS-3). The Non-Return to Zer…
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.5ColumnzxSonetMediumLineTyperead-writecurrentThis variable describes the line type for this interface. The line types are Short and Long Range Single Mode fiber or Multi-Mode fiber interfaces, and coax an…
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.6ColumnzxSonetMediumCircuitIdentifierread-writecurrentThis variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. Note that the circuit identifier, if avai…
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.7ColumnzxSonetMediumInvalidIntervalsread-onlycurrentThe number of intervals in the range from 0 to zxSonetMediumValidIntervals for which no data is available. This object will typically be zero except in cases w…
1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.8ColumnzxSonetMediumLoopbackConfigread-writecurrentThe current loopback state of the SONET/SDH interface. The values mean: sonetNoLoop Not in the loopback state. A device that is not capable of performing a loo…
1.3.6.1.4.1.3902.1015.1013.2.1.3.3TablezxSonetVTConfigTablenot-accessiblecurrentThe Sonet VT Configuration table.
1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1RowzxSonetVTConfigEntrynot-accessiblecurrentAn entry in the Sonet VT Configuration table.
1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.1ColumnzxSonetVTIfIndexnot-accessibledeprecatedThe 4 bytes index includes: interface type(bit31~28);shelfId(bit27~24);slotId(bit23~19);portId(bit18~16);augno(bit15~bit10); au3/au4no(bit9~bit8);tug3no(bit7~b…
1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.2ColumnzxSonetVTLoopbackConfigread-writecurrentThis variable represents the desired loopback configuration of the Sonet VT. Agents supporting read/write access should return inconsistentValue in response to…
1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.3ColumnzxSonetVTTransmitClockSourceread-writecurrentThe source of Transmit Clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock…
1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.4ColumnzxSonetVTClockStatusread-onlycurrentThe current clock state of the sonet VT interface. the value can be: FREERUN 0 HOLDOVER 1 ACQUIRING 2 ACUIRED 3.
1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.5ColumnzxSonetVTCfgInfoSendread-writecurrentThe action to send the configuration on Sonet VT to corresponding card.