MIB Viewer

fcfLineModLinkUpTimer

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.10.2.30.1.1.3
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the management timer in seconds for this serial line interface. It starts when the first call request is sent to the modem and it is normally stopped when the serial line interface is 'up'. The serial line interface state is set to 'down' when this timer runs out. The value of this timer must be larger than the total duration of the successive dialling attempts to not interrupt this processing (see fcfLineModNewDiallingTimer and fcfLineModDiallingCount). This is a decimal integer in the range 1 to 250. The default value is '180'.