0
This object indicates the status of the association between the track interface and the interface monitoring group. By default, the status is normal. triggerdown(2): If the sum of down-weights of the faulty binding interfaces in the interface monitoring group is greater than or equal to the down-weight of the track interface, the track interface is triggered to go Down. triggerup(1):If the track interface is triggered to go Down, and the sum of down-weights of the faulty binding interfaces in the interface monitoring group becomes less than the down-weight of the track interface, the track interface is triggered to go Up.
INTEGER { triggerup(1), triggerdown(2), normal(3) }