MIB Viewer

ps32SwitchOperStatus

OBJECT-TYPE
1.3.6.1.4.1.10.2.1.4.1.6
Access
read-only
Status
mandatory
Sub-identifiers
0
Provides operational status of the switch. The following are possible definitions of the values. The exact definition of the values is implementation specific. A value of other(1) implies some undetermined state, possibly as a result of setting ps32SwitchAdminStatus to a value of disable(3). A value of invalid(2) could have the possible meaning that the agent has no direct control of the switch. A value of testing(3) may be a diagnostic state. A value of operational(4) implies that the switch is running with no errors or warnings. State resetInProgress(5) implies equivalent of setting ps32SwitchAdminStatus to reset(4). The states of warning(6), nonFatalError(7), fatalError(8) reflect conditions detected during operation. The switch may or may not be still functional. State loading(10) is a result of asserting programload(5) in ps32SwitchAdminStatus.
INTEGER { other(1), invalid(2), testing(3), operational(4), resetInProgress(5), warning(6), nonFatalError(7), fatalError(8), loading(10) }