MIB Viewer
MIB Viewer Desktop New

syncSourceStaticQuality

OBJECT-TYPE
1.3.6.1.4.1.8708.2.16.2.3.1.1.13
Access
read-write
Status
current
Sub-identifiers
0
This attribute is used to assign a static G.781 Option 1 Quality level to the source for use in the Synch Source Selection process. Values are interpreted as below: S1 Quality Decsription 0 0 Static Quality Disabled 2 2 Traceable to PRC G.811 4 4 Traceable to Transit G.812 8 8 Traceable to Local G.812 11 11 Derived from SETS 15 15 Do not use for Synchronisation. Other bytes are reserved.
Unsigned32 (0..15)