MIB Viewer

secyTxSCStatsEntry

OBJECT-TYPE
1.0.8802.1.1.3.1.2.2.1
Access
not-accessible
Status
current
Sub-identifiers
4
The entry contains the counters of a transmitting SC. Since some counters in the transmitting SA will be reset while the SA is reused, in order to maintain complete statistics information for the SC, the counters information on the SAs need to be kept in the SC. Those counters that may be reset are : secyTxSAStatsProtectedPkts, secyTxSAStatsEncryptedPkts Each counter for a SC is in the summation of the corresponding counter information for all the SAs, current and prior SAs, belonging to this SC.
SecyTxSCStatsEntry