MIB Viewer

alarmIndex

OBJECT-TYPE
1.3.6.1.2.1.10.3.35.30.1.1.1
Access
read-only
Status
current
Sub-identifiers
0
An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device. alarmIndex of huawei optix devices can be described as following, alarmIndex consists of SLOT_ID,PORT_ID and SUB_PORT_ID. alarmIndex = SUB_PORT_ID<<31 + SLOT_ID<<24 + PORT_ID; 1) bit31(1bit) SUB_PORT_ID: 0 - SUB_PORT_1(east), 1 - SUB_PORT_2(west), for sonet,this para is 0 ,no other means; 2) 24bit~30bit(7bits) SLOT_ID: slot id; 3) 0bit~15bit(16bits) PORT_ID: mac port id; For example: 1:alarmIndex.83886081.122 (gauge) 83886081 83886081 = 0x05000001 can be translated as Slot-5, Port-1; 2:alarmIndex.83886082.122 (gauge) 83886082 83886082 = 0x05000002 can be translated as Slot-5, Port-2;
Unsigned32