MIB Viewer

nnciE1SlotSignalling

OBJECT-TYPE
1.3.6.1.4.1.123.2.20.1.1.7
Access
read-write
Status
mandatory
Sub-identifiers
0
This object is used to select either Common Channel Signalling (CCS) or Channel Associated Signalling (CAS) operation for the interface. CCS operation makes timeslot 16 of the E1 link available for user data . 31CHAN mode allows TS16 to be used for super-rate data, whereas CCS does not. In CAS operation, timeslot 16 is used to transfer ABCD bit signalling and thus is not available to carry user data.
INTEGER { cas(1), ccs(2), thirtyOneChan(3) }