MIB Viewer

cdmaFault2Status

OBJECT-TYPE
1.3.6.1.4.1.13827.11.2.2
Access
read-only
Status
current
Sub-identifiers
0
This is a bit string contained in one character representing the most significant two nibbles of the CDMA fault status word. Unfortunately, SNMP numbers the bits in the reverse order, so that the enumerated values are backwards from the description contained in the User's Manual for the fault status field returned by the cdmastat command. Each bit indicates a fault when set. Currently defined fault states encoded in this value: Bit 7: Primary Redundant Power Supply is Faulting. Bit 6: Secondary Redundant Power Supply is Faulting. Bit 5: Oscillator PLL Faulting. Bit 4: Not Used. Bit 3: Not Used. Bit 2: Not Used. Bit 1: Not Used. Bit 0: Installed System Power exceeds maximum. ATTENTION: This object is deprecated for use in snmpget queries due to a defect in reporting for one specific combination of bits. It remains in this MIB for use with the cdmaTrapFault2StatusChange object, where it reports accurately. Use the new cdmaFaultNibble2Status and cdmaFaultNibble3Status objects for querying via snmpget.
BITS { cdmaSysPwrOvld (0), cdmaNotUsed1 (1), cdmaNotUsed2 (2), cdmaNotUsed3 (3), cdmaNotUsed4 (4), cdmaOscPLLFlt (5), cdmaSecPwrSplyFlt (6), cdmaPriPwrSplyFlt (7) }