MIB Viewer

gpsHP5071AOperNibble2Status

OBJECT-TYPE
1.3.6.1.4.1.13827.14.2.76
Access
read-only
Status
current
Sub-identifiers
0
This is a bit string contained in one character representing the third nibble of the optional HP5071A Cesium Operation status word. Unfortunately, SNMP numbers the bits in the reverse order, so that the enumerated values are backwards from the description contained in the HP5071A User's Manual for the Operation status register. Each bit indicates an Operation state when set. NOTE: If no bits are set in this OID and the gpsHP5071AOperNibble0Status and gpsHP5071AOperNible3Status OIDs, that is an indication of an RS-232 communications fault with the HP5071A. Currently defined states encoded in this value: Bit 3: HP5071A is operating in Standby mode. Bit 2: HP5071A is operating on Battery power. Bit 1: HP5071A is operating Normally. Bit 0: HP5071A has a Fatal error.
BITS { csFatal (0), csNormal (1), csOnBattery (2), csStandby (3) }