MIB Viewer

anxt1BlockInCalls

OBJECT-TYPE
1.3.6.1.4.1.15.2.11.2.1.16
Access
read-write
Status
mandatory
Sub-identifiers
0
When this object is set to enable, then the box will stop accepting calls on this line. This will prevent new users from logging in and should be used to bring the box down gracefully. The default is disable. This object is supported for modules configured for PRI.
INTEGER { enable(1), disable(2) }