MIB Viewer

atmSuPortDataDCD

OBJECT-TYPE
1.3.6.1.4.1.164.12.4.2.1.1.3
Access
read-write
Status
current
Source
ACE20-MIB
Sub-identifiers
0
This attribute define behavior of control signals DCD and RTS These signals may obey or ignore signal from remote device. The terms 'I signal' and 'C signal' are used when physical data interface is X.21 ; RTS = C signal, DCD = I signal
INTEGER { off (1), on (2), obeyRtsDcdOn (3), obeyRtsDcdOff (4), ignoreRtsDcdOn (5), ignoreRtsDcdOff (6), notApplicable (255) }