MIB Viewer

snetSwitchIBCError

TRAP-TYPE
1.3.6.1.4.1.169.8.104
Sub-identifiers
0
ServerNet Switch has detected IBC errors. Possible Cause / Solution: Firmware upgrade or Configuration change: This event can be safely ignored if preceding events indicate a firmware upgrade or configuration change caused the event to be generated. Bad node: Run diagnostics to validate offending nodes are operating correctly. Loose cable: Check cable connections. Bad cable: Check for link error and replace cable. Incompatible software version: Ensure that compatible versions of software and firmware are installed on the offending nodes. Blabbering node: Run diagnostics to ensure that nodes at both ends of the cable are communicating properly. Replace if necessary. Probing node: A node may be trying to break into the network. Isolate the node and verify SAN membership. Switch ownership may be incorrect: Check ownership; cycle power on the offending switch to cause ownership update.