MIB Viewer

tokStatsLineErrors

OBJECT-TYPE
1.3.6.1.4.1.179.2.2.4.1.1.8
Access
read-only
Status
mandatory
Sub-identifiers
0
The line error counter is incremented whenever 1) a frame is repeated or copied, and 2) the error detected indicator is zero in the incoming frame, and 3) at least one of the following conditions exists: a) a code violation between the starting delimiter and the ending delimiter of the frame. b) a code violation in the token c) a Frame Check Sequence (FCS) error. When the line error is incremented, the EDI of the frame is set to one so that no further station count the error.