MIB Viewer

wfMcT1Dsx1ZeroCoding

OBJECT-TYPE
1.3.6.1.4.1.18.3.4.8.2.1.10
Access
read-write
Status
mandatory
Sub-identifiers
0
Selects between the two Zero Code Suppression formats used on the link. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes.
INTEGER { b8zs(2), ami(5) }