wfDs1E1PortLoopbackState

OBJECT-TYPE
1.3.6.1.4.1.18.3.4.9.3.1.11
Access
read-only
Status
mandatory
Sub-identifiers
0
Indicates the current loopback state of this interface. The interface can be in one the following states: Payload Loopback Line Loopback no loopback Payload or Line loopback modes can be initiated by either of two methods: Manager requested Loopback (MGRREQPAYLOADLOOP or MGRREQLINELOOP) is initiated by the Manager of this device. Network requested Loopback (NETREQPAYLOADLOOP or NETREQLINELOOP) is initiated by this interface receiving an in-band request on the network from the far end device.
INTEGER { noloop(1), mgrreqpayloadloop(2), mgrreqlineloop(3), netreqpayloadloop(4), netreqlineloop(5), otherloop(6) }