0
The E1 network interface Sa bit usage. If Sa bits are being used for data link communications, both the near and far end units must agree on which Sa bit to use. Possible value are: VALUE DESCRIPTION ncSaNone(1) No Sa bits are being used for data link communications ncSaBit4(2) Use Sa bit 4 for data link communications ncSaBit5(3) Use Sa bit 5 for data link communications ncSaBit6(4) Use Sa bit 6 for data link communications ncSaBit7(5) Use Sa bit 7 for data link communications ncSaBit8(6) Use Sa bit 8 for data link communications ncTSn Use TimeSlot n for data link communications. These are only available for E1 units with In-Band Link hardware.
INTEGER { ncSaNone (1), ncSaBit4 (2), ncSaBit5 (3), ncSaBit6 (4), ncSaBit7 (5), ncSaBit8 (6), ncTS1 (7), ncTS2 (8), ncTS3 (9), ncTS4 (10), ncTS5 (11), ncTS6 (12), ncTS7 (13), ncTS8 (14), ncTS9 (15), ncTS10 (16), ncTS11 (17), ncTS12 (18), ncTS13 (19), ncTS14 (20), ncTS15 (21), ncTS16 (22), ncTS17 (23), ncTS18 (24), ncTS19 (25), ncTS20 (26), ncTS21 (27), ncTS22 (28), ncTS23 (29), ncTS24 (30), ncTS25 (31), ncTS26 (32), ncTS27 (33), ncTS28 (34), ncTS29 (35), ncTS30 (36), ncTS31 (37) }