MIB Viewer

saHpiHotSwapPolicyCancel

OBJECT-TYPE
1.3.6.1.4.1.18568.2.1.1.2.11.3.1.5
Access
read-write
Status
current
Sub-identifiers
0
A resource supporting hot swap typically supports default policies for insertion and extraction. On insertion, the default policy may be for the resource to turn the associated FRU~s local power on and to de-assert reset. On extraction, the default policy may be for the resource to immediately power off the FRU and turn on a hot swap indicator. This function allows an HPI SNMP Manager, after receiving a hot swap event with saHpiHotSwapState equal to INSERTION_PENDING or EXTRACTION_PENDING, to prevent the default policy from being executed. Once the resource transitions to either the ACTIVE or inactive(1) state, the default policies will once again execute, unless cancelled using saHpiHotSwapPolicyCancel. The default policy cannot be canceled once it has begun to execute. Because a resource that supports the simplified hot swap model will never transition into insertionPending(2) or extractionPending(4) states, this function is not applicable to those resources. Note: Enumerated values are increased by one value compared to SAI-HPI-B spec.
INTEGER { undefined(0), cancel(1) }