MIB Viewer

ansSlotAlarmStatus

OBJECT-TYPE
1.3.6.1.4.1.193.96.115.3.3.1.1.8
Access
read-only
Status
mandatory
Sub-identifiers
0
This variable indicates the current alarm status of the slot. Note that the first three states represent normal states. The different states are exclusive. The alarm codes are: 0: noDefectUnconfiguredEmptySlot (unconfigured empty slot) 1: noDefectConfiguredEmptySlot (configured empty slot, that did not previously contain a matching board) 2: noDefectMatchingBoardInserted (board inserted in the slot that matches the data configured for the slot) 4: boardRemoved (matching board has been removed from the slot) 8: unconfiguredBoardInserted (board inserted in an unconfigured slot) 16: boardMismatch (board inserted in a slot and the board does not match the data configured for the slot) 32: boardUnrecognized (unrecognized board inserted in the slot) 64: Not used. 128: Not used.
INTEGER(0..255)