MIB Viewer

apathUserApathOperation

OBJECT-TYPE
1.3.6.1.4.1.1978.2.1.6.4.1.2
Access
read-write
Status
mandatory
Source
TIGER
Sub-identifiers
0
default = mainPrefered This defines the switching characteristics of main and alternate paths. MAIN PREFERED Re-connect to the main path only. - continuous retry of main path. - disconnect the alternate path in use and switch to the main path when it is known to be UP. - When the main path fails, then attempt to re-establish the path on one of the alternate paths in the order Alternate 1, then Alternate 2, then Alternate 3. SWITCH TO BEST PATH Connect to the best path. - continuous retry of the main path and any path that is higher than the path currently in use. - disconnect the path ans select the highest priority path that is known to be UP. - when a the current path fails, then attempt to re-establish the path based on the priority order of: main, alternate 1, 2, 3. AVOID SWITCHING No automatic switching occurs. - remain connected with the current path as long as it remains UP. - when it fails, or is commanded to disconnect, then re-establish path based on the priority order of: main, alternate 1, 2, 3.
INTEGER { mainPrefered (1), switchToBestPath (2), avoidSwitching (3) }