fe827xPCIAdapFaultStatus

OBJECT-TYPE
1.3.6.1.4.1.2.6.118.4.1.2.2.1.8
Access
read-only
Status
mandatory
Sub-identifiers
0
The fault status of this PCI adapter in this blade. The variable shall assume a value of noFault(2) if no fault that is associated with this adapter has been detected. The variable shall assume a value of isolated(3) if this fault that can be isolated on the adapter itself. The variable shall assume a value of nonIsolated(4) if the fault can not isolated on the adapter or in the network. The variable shall assume a value of unknown(1) if the fault status has not been determined; for example, at initialization. This object would drive the port LED's also. status noFault(2) indicates LED green other values indicate port LED yellow.
INTEGER { unknown(1), noFault(2), isolated(3), nonIsolated(4) }