MIB Viewer

smMlmStatusMonitorFrequency

OBJECT-TYPE
1.3.6.1.4.1.2.6.12.12.1.1.8
Access
read-write
Status
mandatory
Sub-identifiers
0
This indicates how often to status check the interfaces that this policy governs. Frequency units are decimal values appended by the unit: d - day, h - hour, m - minute, s - second, u - millisecond. If no unit is appended, the value is minutes. Multiple values/units are allowed (i.e. 1m30s = 1 minute, 30 seconds). The default frequency is 5 minutes.
DisplayString