MIB Viewer

telProdNpMonFeatBrsDevTSClear

OBJECT-TYPE
1.3.6.1.4.1.2007.4.1.2.4.1.7.1.3
Access
read-write
Status
mandatory
Sub-identifiers
0
This variable is used to make a clear operation: when it is set to 1 (delete), a clear command is executed, starting the measure of the throughput in this moment. The throughput measuring will only take into account those packets which are transmitted after this instant. In reading operations (GET) this variable will show the result of last clear operation attempt: the value is 2 (ok) if clear operation was performed succesfully, 3 (error) if an error ocurred and 4 (undefined) if no clear operations have been made yet.
INTEGER{ delete(1), ok(2), error(3), undefined(4) }