MIB Viewer

hneSysSyncSecondaryRefLineState

OBJECT-TYPE
1.3.6.1.4.1.2158.3.1.1.1.1.2.12
Access
read-only
Status
current
Sub-identifiers
0
This variable indicates the state of the secondary reference line termination point (SONET line) to be used as a timing source by the sync module. This object is relevant if the 'hneSysSyncTimingMode' is set to 'line' and the 'hneSysSyncPrimaryRefLine' is configured. unknown(0) - the state of the line has not been determined. valid(1) - the line is operating within frequency specification. lossOfSignalError - loss of signal was detected from the line and has failed the health check. frequencyOffsetError - frequency errors were detected from the line and has failed the health check
INTEGER { unknown(0), valid(1), lossOfSignalError(2), frequencyOffsetError(3) }